Benchtop pH/Conductivity Meter Bante901 P-UK
$1,058.73
Benchtop pH/Conductivity Meter Bante901 P-UK
High-accuracy multiparameter water quality meter contains 12 options, the meter is suitable for measuring the pH, mV, conductivity and total dissolved solids
- Description
- Size Guide
- Vendor Info
- More Products
Description
Benchtop pH/Conductivity Meter Bante901 P-UK
pH Mode:
• Multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and offset.
Conductivity/TDS Modes:
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear
and pure water compensation modes.

Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-Read function senses and locks the measurement endpoint.
• Calibration due alarm prompts user to calibrate the meter regularly.
• Calibration report provides the details of electrode performance.
• Setup menu allows setting the number of calibration points, stability criteria, temperature
unit, date and time, auto-power off, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface for data transfer and timed interval readings.
ORDER INFORMATION:
| Order Code | Accessories |
| Bante901 P – UK |
P11 glass pH electrode |
| K10 conductivity electrode | |
| TP-10K temperature probe | |
| pH4.01/7.00/10.01 buffer sachets | |
| Conductivity standards 84µS/cm, 1413µS/cm, 12.88mS/cm | |
| USB cable | |
| DC5V power adapter |
SPECIFICATIONS:
| Model | Bante901 | |
| pH | ||
| Range | -2.000~20.000pH | |
| Accuracy | ±0.002pH | |
| Resolution | 0.001, 0.01, 0.1pH, selectable | |
| Calibration Points | 1 to 5 points | |
| pH Buffer Options | USA, NIST, DIN or custom | |
| mV | ||
| Range | ±1999.9mV | |
| Accuracy | ±0.2mV | |
| Resolution | 0.1, 1mV, selectable | |
| Conductivity | ||
| Range | 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |
| Accuracy | ±0.5% F.S | |
| Resolution | 0.001, 0.01, 0.1, 1, automatic | |
| Calibration Points | 1 to 5 points | |
| Calibration Solutions | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm | |
| Temperature Coefficient | Linear (0.0~10.0%/°C) or pure water compensation | |
| Cell Constant | K=0.1, 1, 10 or custom | |
| Reference Temperature | 20°C or 25°C | |
| TDS | ||
| Range | 0~10.00, 100.0, 1000ppm, 10.00, 100.0ppt (Max. 200ppt) | |
| Accuracy | ±1% F.S | |
| Resolution | 0.01, 0.1, 1, automatic | |
| TDS Factor | 0.1~1.0 (Default 0.5) | |
| Temperature | ||
| Range | 0~105°C, 32~221°F | |
| Accuracy | ±0.5°C, ±0.9°F | |
| Resolution | 0.1°C, 0.1°F | |
| Offset Calibration | 1 point | |
| Calibration Range | Measured value ±10°C | |
| General | ||
| Temperature Compensation | 0~100°C, 32~212°F, manual or automatic | |
| Stability Criteria | Low or high | |
| Calibration Due Alarm | 1 to 31 days or off | |
| Memory | Stores up to 500 data sets | |
| Output | USB communication interface | |
| Connector | BNC, 6-pin DIN | |
| Display | 6.5″ custom LCD | |
| Power | DC5V, using AC adapter, 220V/50Hz | |
| Dimensions | 210(L)×188(W)×60(H)mm | |
| Weight | 1.5kg |