Palm Oil Analyzer
$8,547.00
Palmoil Tester: analyzer for crude and refined palm oil
Manufacturer: CDR S.r.l
Product P/N: 222004Z01
OVERVIEW
CDR PalmOilTester is the analysis system for crude and refined palm oil, ideal to perform quality control tests in all production stages or when the oil is used as a supplement.
CDR PalmOilTester can determine:
- Acidity in 1 minute
- Peroxides in 4 minutes
- DOBI & Carotene in 6 minutes
- Iodine value in 2 minutes
- p-Anisidine Value in 2 minutes
Thanks to its ease of use and reliability, CDR PalmOilTester is employed by palm oil producers in Asia, Africa and South America during all production stages.
Furthermore, CDR PalmOilTester is used in testing laboratories or directly on manufacturing lines in many food industries worldwide that use palm oil as a supplement.
It offers an analytical method that combines reliability of results with a simple and rapid use.
- Description
- Size Guide
Description
Palmoil Tester: analyzer for crude and refined palm oil
OVERVIEW
CDR PalmOilTester is the analysis system for crude and refined palm oil, ideal to perform quality control tests in all production stages or when the oil is used as a supplement.
CDR PalmOilTester can determine:
- Acidity in 1 minute
- Peroxides in 4 minutes
- DOBI & Carotene in 6 minutes
- Iodine value in 2 minutes
- p-Anisidine Value in 2 minutes
Thanks to its ease of use and reliability, CDR PalmOilTester is employed by palm oil producers in Asia, Africa and South America during all production stages.
Furthermore, CDR PalmOilTester is used in testing laboratories or directly on manufacturing lines in many food industries worldwide that use palm oil as a supplement.
It offers an analytical method that combines reliability of results with a simple and rapid use.
SPECIFICATION
Technical features
The analysis system consists of a photometric technology analyser, available in two items, and a set of dedicated, ready-to-use reagent kits developed by CDR chemical laboratories.
An innovative photometric technology
Online help for analytical procedures
Multitasking Mode
Internal memory
Barcode and QR Code Reader
The sample code is automatically displayed on the analyser. It is possible to associate all the analyses performed on that sample.
Connection to a host computer or intranet
Free of service and maintenance costs
SYSTEM
The analytical system includes:
- A Spectrophotometric Analyzer with solid state emitters (LEDs) and reading and incubation cells thermostated at 37° C.
- A Kit of pre-vialed, disposable reagents with a low toxicity developed by the research laboratories of CDR and a 12-month shelf-life.
- Pipettes to simplify the collection of the samples.
- Print Manager: software that enables the connection of the analyser to the PC in order to store and print the results of the tests.
- Operator’s manual and functional illustrated sheets.
ANALYSIS
PalmOilTester is able to test raw palm oil and Kernel Palm Oil and provides the following information:
- Free Fatty Acids 1 minute
- Peroxide Value 4 minutes
- DOBI & Carotene 6 minutes
- Iodine Value 2 minutes
- p-Anisidine 2 minutes
This system significantly reduces testing time because it enables to test up to 16 samples simultaneously, which means that it is possible to perform 80 FFA tests, 70 Peroxide Value tests, 40 Iodine Value tests and 40 p-Anisidine Value tests in an hour.
ADVANTAGES
Simple Methods
PalmOilTester analytical methods are simpler and faster as compared to traditional ones. Tests can be performed in a few simple steps:
- Heat the palm oil, which is solid at room temperature.
- Select the parameter to measure from the menu: the system automatically selects the correct wavelength.
- Use the supplied pipette to add the correct volume of reagent and sample, then mix.
- Follow the displayed instructions.
- The result is automatically calculated in a few minutes, displayed and printed by means of the on-board printer.
No Technical Support and Maintenance Expenses
- Unlike NIR systems or other photometric systems, this system does not require regular calibrations: it is supplied pre-calibrated, although the calibration parameters can be changed quickly and simply.
- The system does not require costly spare parts: the analyser uses LED luminous sources and does not therefore require the maintenance that is usually needed for photometers with tungsten luminous filaments. The absence of moving parts eliminates the risk of damages.
In Line with Reference Methods
PalmOilTester and its analytical methods have been subjected to comparative tests by several agencies like Indelab sdn. Bhd. Malaysia, Member Analyst to FOSFA INTERNATIONAL. Tests have demonstrated a good alignment with official AOACS methods.
Solid Documentation
PalmOilTester is supplied with a DVD that contains videos of the methods, which are useful to learn quickly how to perform the tests and obtain the most accurate results.
ANALYTICAL KITS / ACCESSORIES
Analysis | N.Tests | Code | Range |
---|---|---|---|
Free Fatty Acids Low | 100 | *300120 | Palm Oil: 0,01 – 0,54% Palmitic Acid |
Palm Kernel Oil: 0,01 – 0,45% lauric acid | |||
Free Fatty Acids High | 100 | *300129 | 1 – 12,57% Palmitic Acid |
Palm Kernel Oil: 1 – 10,60% lauric acid | |||
Peroxide Value | 100 | *300190 | Refined Oil:0,1 – 25,4 meqO2/Kg |
Raw Oil: 0,5 – 0,5 meqO2/Kg | |||
DOBI & Carotene | 100 | *300195 | DOBI 0,1 – 20 |
Carotene 0,1 – 862,26 ppm of ß-carotene | |||
p-Anisidine Value | 100 | *300510 | 0,5 – 100 AnV |
Iodine Value | 100 | *300555 | 2 – 100 I.V. |