FEATURES OF BI-3000/BI-1000/BI-800 INFANT INCUBATOR
- Infant Temperature Adjustment Range
- Relative Humidity within Operational Environment
- Infant Temperature Deviation Alarm
- Description
- Size Guide
- Additional information
- SPECIFICATIONS OF INFANT INCUBATOR
- Vendor Info
- More Products
Description
INFANT INCUBATOR
Model: BI-3000/BI-1000/BI-800
Manufacturer: PERLONG MEDICAL EQUIPMENT
SPECIFICATIONS OF BI-3000/BI-1000/BI-800 INFANT INCUBATOR
| Model | BI-3000 | BI-1000 | BI-800 |
| Canopy Specifications | |||
| Mattress (canopy) | 450mm | 450mm | 450mm |
| Access Port | 6 (2 Iris ports) | 6 (2 Iris ports) | 4 (2 Iris ports) |
| Self-sealing Tube Ports | 4 | 4 | 2 |
| Front Access Panel | 826x310mm | 826x310mm | 826x310mm |
| Mattress Tray Size | 630x360mm | 630x360mm | 630x360mm |
| Technical Specifications | |||
| Temperature Mode (Servo Controlled) |
air, infant | air, infant | air |
| Air Temperature Adjustment Range | 20°C~37°C, 37~39°C | 20°C~37°C, 37~39°C | 20°C~37°C |
| Infant Temperature Adjustment Range | 30°C~37°C, 37~38°C | 30°C~37°C, 37~38°C | N/A |
| Infant Sensor Accuracy | ≤0.3°C | ≤0.3°C | N/A |
| Relative Humidity Display Range | 5%~99% | N/A | N/A |
| Temperature Fluctuation | ≤0.5°C | ≤0.5°C | ≤0.5°C |
| Uniformity of Mattress Temperature | ≤0.8°C | ≤0.8°C | ≤0.8°C |
| Time to Warm Up | ≤30 min | ≤30 min | ≤30 min |
| Noise Level within Canopy | ≤55dB | ≤55dB | ≤55dB |
| Alarms | |||
| Power Failure Alarm | Yes | Yes | Yes |
| Fan Failure Alarm | Yes | Yes | Yes |
| Sensor Failure Alarm | Yes | Yes | Yes |
| Air Temperature Deviation Alarm | ±3.0°C | ±3.0°C | ±3.0°C |
| Infant Temperature Deviation Alarm | ±1.0°C | ±1.0°C | N/A |
| Air Temperature Exceeds set Limit Alarm | ≤38.0°C; ≤40.0°C | ≤38.0°C; 40.0°C | ≤38.0°C |
| Infant Temperature Exceeds set Limit alarm | ≤38.0°C; ≤39.0°C | ≤38.0°C; 39.0°C | N/A |
| System Failure Alarm | Yes | Yes | N/A |
| Mute Alarm Function | Yes | Yes | N/A |
| Operational Environment | |||
| Temperature within Operational Environment | +20°C~+30°C | +20°C~+30°C | +20°C~+30°C |
| Relative Humidity within Operational Environment | 5%~99% | 5%~99% | 5%~99% |
| Velocity of Air Flow within Operational Environment | <0.3m/s | <0.3m/s | <0.3m/s |
| Other Specifications | |||
| RS-232 connector | Yes | Yes | N/A |
| Tilt of Infant Bed (Adjustment Range) |
±10° step-less | ±10° step-less | N/A |
| Maximum Load of Mattress Tray | 5kg | 5kg | 5kg |
| Maximum Load of IV Stand | 2kg | 2kg | 2kg |
| Maximum Load of Cabinet | 6kg | 6kg | N/A |
PRODUCT SHOW
BI-800
BI-1000
BI-3000
Additional information
| MODEL | BI-3000, BI-1000, BI-800 |
|---|
| Model | BI-3000 | BI-1000 | BI-800 |
| Canopy Specifications | |||
| Mattress (canopy) | 450mm | 450mm | 450mm |
| Access Port | 6 (2 Iris ports) | 6 (2 Iris ports) | 4 (2 Iris ports) |
| Self-sealing Tube Ports | 4 | 4 | 2 |
| Front Access Panel | 826x310mm | 826x310mm | 826x310mm |
| Mattress Tray Size | 630x360mm | 630x360mm | 630x360mm |
| Technical Specifications | |||
| Temperature Mode (Servo Controlled) |
air, infant | air, infant | air |
| Air Temperature Adjustment Range | 20°C~37°C, 37~39°C | 20°C~37°C, 37~39°C | 20°C~37°C |
| Infant Temperature Adjustment Range | 30°C~37°C, 37~38°C | 30°C~37°C, 37~38°C | N/A |
| Infant Sensor Accuracy | ≤0.3°C | ≤0.3°C | N/A |
| Relative Humidity Display Range | 5%~99% | N/A | N/A |
| Temperature Fluctuation | ≤0.5°C | ≤0.5°C | ≤0.5°C |
| Uniformity of Mattress Temperature | ≤0.8°C | ≤0.8°C | ≤0.8°C |
| Time to Warm Up | ≤30 min | ≤30 min | ≤30 min |
| Noise Level within Canopy | ≤55dB | ≤55dB | ≤55dB |
| Alarms | |||
| Power Failure Alarm | Yes | Yes | Yes |
| Fan Failure Alarm | Yes | Yes | Yes |
| Sensor Failure Alarm | Yes | Yes | Yes |
| Air Temperature Deviation Alarm | ±3.0°C | ±3.0°C | ±3.0°C |
| Infant Temperature Deviation Alarm | ±1.0°C | ±1.0°C | N/A |
| Air Temperature Exceeds set Limit Alarm | ≤38.0°C; ≤40.0°C | ≤38.0°C; 40.0°C | ≤38.0°C |
| Infant Temperature Exceeds set Limit alarm | ≤38.0°C; ≤39.0°C | ≤38.0°C; 39.0°C | N/A |
| System Failure Alarm | Yes | Yes | N/A |
| Mute Alarm Function | Yes | Yes | N/A |
| Operational Environment | |||
| Temperature within Operational Environment | +20°C~+30°C | +20°C~+30°C | +20°C~+30°C |
| Relative Humidity within Operational Environment | 5%~99% | 5%~99% | 5%~99% |
| Velocity of Air Flow within Operational Environment | <0.3m/s | <0.3m/s | <0.3m/s |
| Other Specifications | |||
| RS-232 connector | Yes | Yes | N/A |
| Tilt of Infant Bed (Adjustment Range) |
±10° step-less | ±10° step-less | N/A |
| Maximum Load of Mattress Tray | 5kg | 5kg | 5kg |
| Maximum Load of IV Stand | 2kg | 2kg | 2kg |
| Maximum Load of Cabinet | 6kg | 6kg | N/A |