BOD Sensor System 6 230V/60Hz
$1,972.14
BOD Sensor System 6 230V/60Hz
MANUFACTURER: VELP
CAT NO: S10230136
- Description
- Size Guide
- SPECIFIATION
- DOWNLOAD
Description
BOD Sensor System 6 230V/60Hz
BOD Determination made easy
BOD (Biochemical Oxygen Demand) Determination is a simple and easy way for monitoring the microorganisms’ activity in water samples with extremely reliable results.
In particular, microorganisms present or inoculated in a water sample containing biodegradable organic substance, consume oxygen for their metabolic activity and produce a corresponding volume of carbon dioxide.
The carbon dioxide get absorbed by a strong alkali positioned in the neck of the bottle. The result of this process is a decrease in gas pressure. The BOD measure this change in gas pressure between the beginning to the end of the analysis and give a result expressed in mg/l .
Safe and Easy to use
- Measurement on scales of 90, 250, 600, 999 and 4000 ppm BOD
- Higher values can be measured by diluting the sample
- Fits directly on the bottle containing the sample
- Automatically stores 5 BOD values at 24-hour intervals
- Enables analysis to continue over the weekend
- Results directly readable at any time, even after five days
- Direct readout in mg/l (ppm)
- Compact stirring stations
- Models with stirring stations offer VELP stirring quality
- IP 54 protection against particle and liquid ingress
- Class 3 IEC 1010 conformity
NUMBER OF SENSORS INCLUDING: | BOD Sensor 1 BOD Sensor Set 1 BOD Sensor System 6 6 BOD Sensor System 10 10 |
SENSOR DISPLAY: | 4-digit LED display |
BOD MEASUREMENT: | mg/l (ppm) directly on the display |
TEST TYPOLOGY: | BOD |
BOD SCALES: | 90, 250, 600, 999, 4000 ppm, Higher values after dilution |
BOTTLE VOLUMES: | 500 ml |
DATA STORAGE: | BOD values at 24h intervals |
SENSOR CONSTRUCTION MATERIAL: | Technopolymer |
POWER: | BOD Sensor – BOD Sensor Set – BOD Sensor System 6 2 W BOD Sensor System 10 2 W |
SENSOR BATTERY TYPE: | CR 2430 |
POWER SUPPLY: | BOD Sensor 2x3V lithium batteries BOD Sensor Set 2x3V lithium batteries BOD Sensor System 6 Sensors: 2x3V lithium batteries Stirring Station: 230V / 50-60Hz or 115V / 60Hz BOD Sensor System 10 Sensors: 2x3V lithium batteries Stirring Station: 230V / 50-60Hz or 115V / 60Hz |
DIMENSIONS (WXHXD): | BOD Sensor 55x71x73 mm (2.1×2.8×2.9 in) BOD Sensor Set 75x230x75 mm (3.0×9.3×3.0 in) BOD Sensor System 6 270x300x185 mm (10.6×11.8×7.3 in) BOD Sensor System 10 432x300x165 mm (17.0×11.8×6.5 in) |
WEIGHT: | BOD Sensor 0,08 kg (0.2 lb) BOD Sensor Set 0,4 kg (0.9 lb) BOD Sensor System 6 2,3 Kg (5.1 lb) BOD Sensor System 10 3 Kg (6.6 lb) |
SAFETY CLASS: | IEC/EN61010-1 |
SENSOR PROTECTION DEGREE: | IP 54-EN 60529 |
OFFICIAL REFERENCES | ISO 5815-1:2019 STANDARD METHOD 5210D |