Clamp-On Meters-CMP-600

$468.41

CLAMP-ON METERS-CMP-600

Clamp-On Meters-CMP-600

Manufacturer: Sonel S.A.

Product code: EA-51511-3

AC/DC  current measurement (TRUE RMS) up to 600A

AC/DC voltage measurement (TRUE RMS) up to 600 V

Acoustic signaling programmable for instances of exceeding the MAX/MIN values set.

Can be wirelessly connected to many transmitters

Receiver made compatible with a computer via USB interface

Resistance measurement and continuity test:

  • continuity test with acoustic signaling (beeper) for resistance below 1000.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.

Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,
  • AUTO-OFF function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40
SKU: WMXXCMP600
View cart

Description

CLAMP-ON METERS-CMP-600

Clamp-On Meters-CMP-600

AC/DC  current measurement (TRUE RMS) up to 600A

AC/DC voltage measurement (TRUE RMS) up to 600 V

Acoustic signaling programmable for instances of exceeding the MAX/MIN values set.

Can be wirelessly connected to many transmitters

Receiver made compatible with a computer via USB interface

Resistance measurement and continuity test:

  • continuity test with acoustic signaling (beeper) for resistance below 1000.

Temperature measurement (Fahrenheit and Celsius units).
Frequency measurement.
Diode test.

Additionally:

  • safe, insulated measuring clamps,
  • double molded housing,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • REL function,
  • over range indication,
  • AUTO-OFF function.

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 2×1.5 V battery type LR6
  • display: LCD, 4 digits
  • uninterrupted work time: 300h transmission off, 100h transmission on (t=2)
  • transmitter’s dimensions: 220 x 64 x 35 mm
  • receiver’s dimensions: 179x 72 x 32 mm
  • transmitter’s weight (without batteries): 251g
  • receiver’s weight (without batteries): 177g
  • sampling rate: 3 times/sec transmission on and 1 times/sec transmission on
  • transmission frequency: 433,62MHz
  • polarization: automatic, negative polarization indicated (-)
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: -10…540°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <70%
  • operating altitude: max 2000m

SPECIFICATION

DC and AC (TRUE RMS-50…500Hz) current measurement

Range Resolution Accuracy (DC) Acuracy (AC)
400A 0.001 A ±(1.8% m.v. + 10 dgt) ±(1.8% m.v. + 10 dgt)
for f=50…500 Hz
600 A 1A ±(1% m.v. + 5 dgt) ±(1.8% m.v. + 5 dgt)
for f=50…500 Hz

DC and AC (TRUE RMS-50…500Hz) current measurement

Range Resolution Accuracy
DC AC
400mV 0.1 mV ±(0.75% m.v. + 3 dgt)
4V 0.001 V ±(1% m.v. + 3 dgt) ±(1.5% m.v. + 10 dgt)
40V 0.01 V
400V 0. V ±(1.5% m.v. + 5 dgt)
600V 0.1 V

*- only DC

Resistance measurement

 Range Resolution Accuracy
400Ω 0.1 Ω
4kΩ 0.001 kΩ ±(1.0% m.v + 4 dgt)
40kΩ 0.01 kΩ
400 kΩ 0.1 kΩ
4 MΩ 0.001 MΩ ±(3.5% m.v. + 5 dgt)
40MΩ 0.01 MΩ

Frequency Measurement

 Range Resolution Accuracy
5Hz 0.001 Hz
50Hz 0.01 Hz      ±(0.75% m.v. + 5 dgt)
500Hz 0.1 Hz
5Hz 0.001 KHz
50Hz 0.01 KHz
5Hz 0.1 KHz

“m.v.”- measured value