Controller for pH, ORP and temperature (w/ Pt100 sensor) – S503-pH/RX/T
The S503 instruments are microprocessor-based digital devices, designed for panel installation. All models feature 2 relay outputs (settable as set-points or alarm thresholds), one current output completely configurable and galvanically insulated. All outputs may be temporary deactivated (e.g. during maintenance) through the ON button. Alarms and errors are shown directly on the display, and calibration and configuration data are saved into the non-volatile memory for at least 10 years.
The S503 series includes several models, for measuring the following parameters:
- pH / ORP (redox) / Temperature
- Conductivity
- Indicator (model with standardized input)
All models feature a temperature input for Pt100 sensor, for temperature measurement and compensation of the pH and conductivity.
TECHNICAL DATA
- pH / ORP Input removable, 3-pole terminal block (coaxial cable + reference); input impedance > 10^12 Ω; pH range: 0…14.00 pH; ORP range: -1000 ….+1000 mV
- Temperature Input removable, 2-pole terminal block, for connection of Pt100 sensor; range: -100 … +200 °C
- Analogic Inputs: precision better than 0.3% FS / repeatability better than 0.2% FS (electronics only)
- Power supply: 100-240 V~ 50/60 Hz (24V~, 24V- upon request)
- Power Consumption: 5 VA max
- Protection: 5×20 fuse that can be accessed from the rear panel; 24 V~ F 250 mA; 100-240 V~ F 100 mA
- Display: 2-row, alphanumeric LCD (8 digits per row), with backlight
- Relay Outputs: 2 independent outputs, available on removable, 5-pole terminal block; contact max load: 250 V~, 3 A resistive.
- Current Output: 0/4-20 mA (selectable through software), 600 Ω max load, 0.5% FS max error; galvanically isolated from inputs
- Environment: storage temperature -20 to +60 °C
operating temperature -10 to +50 °C
RH max 90% no condensing - Casing: NORYL body, polyester front panel; designed for panel installation with supplied mounting brackets.
- Protection rate: IP42, panel-mounted without front protection; IP54 with optional cover (upon request: version with IP65 housing)
- Dimensions: instrument: DIN 96 x 96 x 115 mm; drilling template: 90 x 90 mm
- Weight: approx. 400 gx
- pH / ORP Input removable, 3-pole terminal block (coaxial cable + reference); input impedance > 10^12 Ω; pH range: 0…14.00 pH; ORP range: -1000 ….+1000 mV
- Temperature Input removable, 2-pole terminal block, for connection of Pt100 sensor; range: -100 … +200 °C
- Analogic Inputs: precision better than 0.3% FS / repeatability better than 0.2% FS (electronics only)
- Power supply: 100-240 V~ 50/60 Hz (24V~, 24V- upon request)
- Power Consumption: 5 VA max
- Protection: 5×20 fuse that can be accessed from the rear panel; 24 V~ F 250 mA; 100-240 V~ F 100 mA
- Display: 2-row, alphanumeric LCD (8 digits per row), with backlight
- Relay Outputs: 2 independent outputs, available on removable, 5-pole terminal block; contact max load: 250 V~, 3 A resistive.
- Current Output: 0/4-20 mA (selectable through software), 600 Ω max load, 0.5% FS max error; galvanically isolated from inputs
- Environment: storage temperature -20 to +60 °C
operating temperature -10 to +50 °C
RH max 90% no condensing - Casing: NORYL body, polyester front panel; designed for panel installation with supplied mounting brackets.
- Protection rate: IP42, panel-mounted without front protection; IP54 with optional cover (upon request: version with IP65 housing)