Description
Differential Scanning Calorineter
Calorimetric analyzer measures the relationship between temperature and heat flow related to the internal heat transition of materials. It has a wide range of applications, especially in the research and development, performance testing and quality control of materials. Such as material melting, glass transition temperature, crystallization and cold crystallization, phase transition, thermal stability, curing/crosslinking, oxidation rust lead period and so on. Jiahang DSC in line with the national standard GB/T15065-2009, GB/T2951.42-2008, GB/T17391-1998, GB/T19466.6-2009 standard.
Calorimetric analyzer Introduction
Instrument innovation:
1: Closed furnace body structure to ensure heating stability;
2: 56 pairs of thermocouples provide high sensitivity resolution;
3: High-precision AD detection to ensure a flat baseline;
4: 7-inch LCD touch screen display.
Calorimetric analyzer Feature And Application
1: Closed furnace body structure to ensure heating stability;
2: 56 pairs of thermocouples, greatly improving the temperature sensitivity and resolution;
3: Brand new furnace structure, better resolution and resolution, and better baseline stability;
4: Dual temperature probes to ensure high repeatability of sample temperature measurement;
5: The software is adaptive to computers of various brands and supports WINXP, WIN7, WIN8, WIN10 and other operating systems;
6: Humanized operation interface, friendly interface and easy operation.
Fields of use Product
Calorimetric analyzer has a wide range of applications, especially in the research and development, performance testing and quality control of materials.
Product Qualification
Jiahang Product has obtained CE certification, TART certification, ISO quality management system certification, more than 10 software copyrights and multiple patents to ensure that each instrument has stable performance and excellent quality.
Model | JH-DSC6 |
temperature range | Room temperature -600℃ |
Temperature resolution | 0.01℃ |
Temperature accuracy | 0.1℃ |
Temperature accuracy | ±0.03℃ |
DSC range | ±500mW |
DSC resolution | 0.001mW |
Calorimetry accuracy | 0.1% |
Heating rate | 0.1~100℃/ min |
Cooling rate | 0.1~50℃/ min |
Maximum data collection rate | 50 pcs/ s |
Temperature control method | Heating, constant temperature, cooling, cycle temperature control (full program automatic control) |
Atmosphere control | Gas mass flow meter automatically switches between two gases |
Display method | 8-inch color touch screen |
Parameter standard | Equipped with standard samples, one-key automatic calibration, users can calibrate the temperature by themselves |
Data interface | USD2.0 interface, dedicated operating software |
Power supply | 50Hz / 60 Hz AC220V |