Digital Pressure module, 0.02%FS, 0 to 150 psi, gauge pressure, 1/2NPT M
$1,713.18
MANUFACTURER: ADDITEL
PART NO:ADT160A-02-GP150-PSI-N
- Description
- Size Guide
- SPECIFICATION
- DATASHEET
Description
Digital Pressure module, 0.02%FS, 0 to 150 psi, gauge pressure, 1/2NPT M
Description of Digital Pressure module, 0.02%FS, 0 to 150 psi, gauge pressure, 1/2NPT M
With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 161 and 161Ex series Digital Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our intrinsically safe (Ex) models are up to the task of providing the best possible results, even in hazardous environments. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure modules for Additel’s 760 automatic handheld pressure calibrator, the ADT761 automated pressure calibrator, ADT226/ADT227 series handheld process calibrator and Additel’s flagship 780 pressure controller, the Additel 161 is unmatched in performance and reliability. If intrinsic safety is a critical requirement for your workload, we have you covered when you combine our model ADT226Ex/ADT227Ex process calibrator with any of our ADT161Ex pressure modules.
K | 40000 | 2800 | G , L | 0.1 | 1.35x |
GP50K | 50000 | 3500 | G , L | 0.1 | 1.2x |
GP60K | 60000 | 4200 | G , L | 0.1 | 1.1x |
[1]. Sealed gauge pressure for above 1000 psi [2]. G=Gas, L=Liquid |
Differential Pressure | ||||||
---|---|---|---|---|---|---|
P/N | Pressure Range[1] | Media | Accuracy (%FS) | Burst Pressure | Static Pressure Range | |
(inH2O) | (mbar) | |||||
DP1 | ±1 | ±2.5 | G | 0.05[2] | 100× | ±10 psi |
DP2 | ±2 | ±5.0 | G | 0.05[2] | 100× | ±10 psi |
DP5 | ±5 | ±10 | G | 0.05[2] | 50× | ±10 psi |
DP10 | ±10 | ±25 | G | 0.05[2] | 20× | ±10 psi |
DP20 | ±20 | ±50 | G | 0.05 | 20× | ±10 psi |
DP30 | ±30 | ±75 | G | 0.05 | 20× | ±10 psi |
DP50 | ±50 | ±160 | G | 0.05 | 3× | ±10 psi |
DP150 | ±150 | ±350 | G | 0.02 | 3× | 50 psi |
DP300 | ±300 | ±700 | G | 0.02 | 3× | 50 psi |
[1] FS specification applies to the span of the range. Accuracy includes 1 year stability. [2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability. |
Compound Pressure | ||||||
---|---|---|---|---|---|---|
P/N | Pressure Range | Media | Accuracy | Pressure Rating | ||
psig | bar.g | Burst | Over Pressure | |||
CP2 | ±2 | ±0.16 | G | 0.05% FS | 3x | 1.2x |
CP5 | ±5 | ±0.35 | G | 0.02% FS | 3x | 1.2x |
CP10 | ±10 | ±0.7 | G | 0.02% FS | 3x | 1.2x |
CP15 | ±15 | ±1.0 | G | 0.02% FS | 3x | 1.2x |
CP30 | -15 to 30 | -1 to 2.0 | G | 0.02% FS | 3x | 1.2x |
CP50 | -15 to 50 | -1 to 3.5 | G | 0.02% FS | 3x | 1.2x |
CP100 | -15 to 100 | -1 to 7.0 | G,L | 0.02% FS | 3x | 1.2x |
CP300 | -15 to 300 | -1 to 20 | G,L | 0.02% FS | 3x | 1.2x |
CP500 | -15 to 500 | -1 to 35 | G,L | 0.02% FS | 3x | 1.2x |
CP600 | -15 to 600 | -1 to 40 | G,L | 0.02% FS | 3x | 1.2x |
CP1K | -15 to 1,000 | -1 to 70 | G,L | 0.02% FS | 3x | 1.2x |
CP2K | -15 to 2,000 | -1 to 140 | G,L | 0.02% FS | 3x | 1.2x |
CP3K | -15 to 3,000 | -1 to 200 | G,L | 0.02% FS | 3x | 1.2x |
CP5K | -15 to 5,000 | -1 to 350 | G,L | 0.02% FS | 3x | 1.2x |
CP10K | -15 to 10,000 | -1 to 700 | G,L | 0.02% FS | 2x | 1.2x |
Absolute Pressure | |||||
---|---|---|---|---|---|
P/N | Pressure Range | Media | Accuracy (%FS) | Burst Pressure | |
psi | bar | ||||
AP5 | 5 | 0.35 | G | 0.1 | 3× |
AP10 | 10 | 0.7 | G | 0.1 | 3× |
AP15 | 15 | 1 | G | 0.1 | 3× |
AP30 | 30 | 2 | G | 0.1 | 3× |
AP50 | 50 | 3.5 | G | 0.1 | 3× |
AP100 | 100 | 7 | G , L | 0.05 (0.1) | 3× |
AP300 | 300 | 20 | G , L | 0.05 (0.1) | 3× |
AP500 | 500 | 35 | G , L | 0.05 (0.1) | 3× |
AP1K | 1000 | 70 | G , L | 0.05 (0.1) | 3× |
AP3K | 3000 | 200 | G , L | 0.05 (0.1) | 3× |
AP5K | 5000 | 350 | G , L | 0.05 (0.1) | 3× |
Precision Sensors[1] – Absolute Pressure | ||||||
---|---|---|---|---|---|---|
P/N | Pressure Range | Media | Accuracy[2] | Pressure Rating | ||
psia | bar.a | Burst | Over Pressure | |||
AP15R | 0 to 15 | 0 to 1 | G | 0.01% FS | 2x | 1.2x |
AP30R | 0 to 30 | 0 to 2 | G | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP50R | 0 to 50 | 0 to 3.5 | G | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP100R | 0 to 115 | 0 to 8 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP300R | 0 to 315 | 0 to 21 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP500R | 0 to 515 | 0 to 36 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP1KR | 0 to 1,015 | 0 to 71 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
AP2KQ | 0 to 2,015 | 0 to 141 | G | 0.005% rdg + 0.005% FS | 3x | 1.1x |
AP3KQ | 0 to 3,015 | 0 to 201 | G | 0.005% rdg + 0.005% FS | 3x | 1.1x |
AP6KQ | 0 to 6,000 | 0 to 400 | G,L | 0.01% FS | 3x | 1.2x |
AP10KQ | 0 to 10,000 | 0 to 700 | G,L | 0.01% FS | 2x | 1.2x |
AP15KQ | 0 to 15,000 | 0 to 1000 | G,L | 0.01% FS | 2x | 1.2x |
AP20KQ | 0 to 20,000 | 0 to 1400 | G,L | 0.01% FS | 2x | 1.2x |
AP30KQ | 0 to 30,000 | 0 to 2000 | G,L | 0.02% FS | 1.5x | 1.1x |
AP40KQ | 0 to 40,000 | 0 to 2800 | G,L | 0.02% FS | 1.5x | 1.1x |
[1] Contact Additel for other range options. [2] Accuracy includes calibration uncertainty, linearity and long-term stability. |
Barometric Pressure | |||||
---|---|---|---|---|---|
P/N | Pressure Range | Media | Accuracy | Burst Pressure | |
Low | High | ||||
BP | 60 kPa | 110 kPa | G | 40 Pa | 3× |