ELECTROCARDIOGRAPHY MACHINE ECG-601G
$855.00
ELECTROCARDIOGRAPHY MACHINE
Model: ECG-601G (6-Channel)
Manufacturer: PERLONG MEDICAL EQUIPMENT
ECG-601G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system.
FEATURES OF ELECTROCARDIOGRAPHY MACHINE ECG-601G
- Full-digital filter design, anti-baseline drift, AC and EMG interference.
- Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
- In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
- Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
- With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
- Description
- Size Guide
- SPECIFICATIONS OF ELECTROCARDIOGRAPHY MACHINE ECG-601G
Description
Description
ELECTROCARDIOGRAPHY MACHINE
Model: ECG-601G (6-Channel)
Manufacturer: PERLONG MEDICAL EQUIPMENT
ECG-601G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, case database management.
FEATURES OF ELECTROCARDIOGRAPHY MACHINE ECG-601G
- Adopt high-resolution thermal printing system(8 dot/mm), no need for any adjustments. Recording frequency: up to 150Hz.
- Real-time and continuously record the clear and accurate ECG waveform and annotation character(including lead mark, sensitivity, paper speed and filter state, etc.).
- Full-digital filter design, anti-baseline drift, AC and EMG interference.
- Adjust the baseline automatically, optimize the print setting and optional rhythm leads.
- In AUTO mode, finish recording by pressing the button once, which improves work efficiency.
- Adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
- With the functions of auto-measurement, auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden and improves work efficiency.
- Sync collection for 12-lead ECG, multiply printing formats, including 2×6+1(rhythm lead), 2×6, 3×4, 3×4+1(rhythm lead), 4×3, 4×3+1(rhythm lead), 6×2, 6×2+1(rhythm lead), rhythm 2, rhythm 3, rhythm 4, rhythm 5, rhythm 6, rhythm 7, channel record, etc.
- Display of 3/6/12-lead ECG, “Lead off” and “Lack of paper” on one screen, and with ECG DEMO mode. Auto-check and auto-analysis for ECG parameters, ECG waveform can be recorded manually or automatically. And patient information can be stored by case database.
- Time print can be set to every 1/2/3/5/10/20/30/60 minutes.
- Print setting, including “Print and save”(print waveform and save case), “Print no save”(only print waveform but not save case), “Save no print”(only save case but not print waveform).
- AC/DC, built-in rechargeable lithium battery and auto-protection circuit, and automatic power off when there is no operation in appointed time.
- Store more than 1000 cases, convenient for case review and statistic.
- Multi-language(Chinese, English, French, Spanish, Turkish, Polish, Italian, German, Portuguese, Kazakstan, Russian and Ukrainian) interface and report.
SPECIFICATIONS OF ELECTROCARDIOGRAPHY MACHINE ECG-601G
MODEL | ECG-601G |
Input mode | floating and defibrillation protection |
Frequency response | 0.05Hz ~ 150Hz(-3dB~+0.4dB) |
CMRR | >60dB, >100dB(add filter) |
Time | constant:≥ 3.2s |
Patient leak current | <10µA |
Calibration voltage | 1mV |
Sensitivity | 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% |
Noise level | <15µVp-p |
Input circuit current | ≤50nA |
Input impedance | ≥50MΩ |
Sampling accuracy | 12-bit |
Safety classification: | class I, type CF and defibrillation-proof applied part |
Recording mode | thermal printing system |
Auto record | set record according to auto record format and mode, automatically switching leads, measuring and analyzing. |
Rhythm record | set record according to rhythm record format and mode, automatically measuring and analyzing. |
Manual record | set record according to record format, manually switching leads. |
Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) |
Paper size | 80mm(W)×20m(L) |
Power frequency filter | AC 50Hz/60Hz(-20dB) |
Sampling frequency | 1000Hz |
EMG interference filter | 25Hz/35Hz (-3dB) |
Paper speed |
Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5% |
Physical characteristic:
Dimension: 315mm(L) × 215mm(W) × 92mm(H)
Weigh: 1.7Kg
Print
Recording way: Thermal printing system
Specification of recording paper: 110mm(W)×20m(L) High-speed thermal paper
Paper speed:
Auto-record:25mm/s,50mm/s,error:±5%
Rhythm record:25mm/s,50mm/s,error:±5%
Manual_record:5mm/s,6.25mm/s,10mm/s,12.5mm/s,25mm/s,50mm/s,100mm/s,error:±5%
PRODUCT SHOW
Size Guide
SPECIFICATIONS OF ELECTROCARDIOGRAPHY MACHINE ECG-601G
MODEL | ECG-601G |
Input mode | floating and defibrillation protection |
Frequency response | 0.05Hz ~ 150Hz(-3dB~+0.4dB) |
CMRR | >60dB, >100dB(add filter) |
Time | constant:≥ 3.2s |
Patient leak current | <10µA |
Calibration voltage | 1mV |
Sensitivity | 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2% |
Noise level | <15µVp-p |
Input circuit current | ≤50nA |
Input impedance | ≥50MΩ |
Sampling accuracy | 12-bit |
Safety classification: | class I, type CF and defibrillation-proof applied part |
Recording mode | thermal printing system |
Auto record | set record according to auto record format and mode, automatically switching leads, measuring and analyzing. |
Rhythm record | set record according to rhythm record format and mode, automatically measuring and analyzing. |
Manual record | set record according to record format, manually switching leads. |
Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1) |
Paper size | 80mm(W)×20m(L) |
Power frequency filter | AC 50Hz/60Hz(-20dB) |
Sampling frequency | 1000Hz |
EMG interference filter | 25Hz/35Hz (-3dB) |
Paper speed |