Elemental Analyzers of Sulfur and Nitrogen

Elemental Analyzers of Sulfur and Nitrogen

SKU: EA-11135-1

Description

Elemental Analyzers of Sulfur and Nitrogen

Thanks to the new generation of 2M detectors, we have developed an analyzer to measure both sulfur and nitrogen simultaneously on a single sample.

This elemental analyzer allows:

  • To reduce the manipulations carried out by the operators
  • Save time while analyzing sulfur and nitrogen
  • Save space in your lab
  • Reduce the cost of consumables and maintenance
  • Measure simultaneously sulfur and nitrogen, or either sulfur alone or nitrogen alone.

 

Analysers adapted to the standards ASTM D5453 / ASTM D6667 / ISO 20 846 …

It automatically and rapidly measures the very low levels of sulfur / nitrogen in petroleum products: up to 20 ppb of sulfur and 30 ppb of nitrogen. It can also be associated with the liquid injector or the liquid automatic sampler, or the Gas / LPG sampler.

  • Technical specifications

    Principle: Combustion – UV Fluorescence / Chemiluminescence

     

    Detection Limit: 10 ppb S / 20 ppb N to 10%
    Quantification: 20 ppb S / 30 ppb N to 10%

     

    Accuracy S / RSD S:

    • At 0.1 ppm: 0.61 %
    • At 1 ppm: 0.48 %
    • At 100 ppm: 1.04 %

     

    Accuracy N / RSD N:

    • At 0.3 ppm: 0.97 %
    • At 1 ppm: 0.78 %
    • At 100 ppm: 1.10 %

     

    Injections:

    20 to 80 µl liquids 1 to 25 ml gas 10µL LPG

     

    Supply Gas:

    • Oxygen: 99.998% – 3 bar
    • Argon: 99.995 % – 3 bar

     

    Electric:

    110 V / 230 V
    60Hz – 50 Hz
    1200 W

     

    Temperature:

    • Furnace F2 25 to 1050°C
    • Furnace F1 programmable 25 to 980°C
  • Applications

    Measure Sulfur and Nitrogen simultaneously, quickly and accurately in petroleum product, solvent, oil, synthetic product, water, LPG, plastics…

     

    According standards:

    ASTM D5453, ASTM D6667, ASTM D7183, ISO 20846, ASTM D4629, ASTM D6069, ASTM D5176, ASTM D5762, NF EN 12260

  • Modes

    • Horizontal furnace configuration / compatible with syringe pusher
      All types of samples: Solids, Liquids, Gaseous
    • Vertical furnace configuration / compatible with auto injector
      All types of samples: Solids, Liquids, Gaseous
  • Options

    • Liquid Automatic Sampler up to 50 positions
    • Automatic sampler for Gas and/or LPG, with 2 injections loops
    • Mini automatic injector, for liquid samples from 5 to seven positions
    • Auto introductor for solids samples with boat support

Principle: Combustion – UV Fluorescence / Chemiluminescence

 

Detection Limit: 10 ppb S / 20 ppb N to 10%
Quantification: 20 ppb S / 30 ppb N to 10%

 

Accuracy S / RSD S:

  • At 0.1 ppm: 0.61 %
  • At 1 ppm: 0.48 %
  • At 100 ppm: 1.04 %

 

Accuracy N / RSD N:

  • At 0.3 ppm: 0.97 %
  • At 1 ppm: 0.78 %
  • At 100 ppm: 1.10 %

 

Injections:

20 to 80 µl liquids 1 to 25 ml gas 10µL LPG

 

Supply Gas:

  • Oxygen: 99.998% – 3 bar
  • Argon: 99.995 % – 3 bar

 

Electric:

110 V / 230 V
60Hz – 50 Hz
1200 W

 

Temperature:

  • Furnace F2 25 to 1050°C
  • Furnace F1 programmable 25 to 980°C
You've just added this product to the cart: