Flow meter insertion type-VA 550 – Flow sensor for installation in existing compressed air or gas line of 3/4″ to DN 1000

$3,682.43

Flow meter insertion type-VA 550 –

Flow sensor for installation in existing compressed air or gas line of 3/4″ to DN 1000. VA 550 Flow meter, measuring head in robust aluminum die casting housing

Description

Flow meter insertion type-VA 550 – Flow sensor for installation in existing compressed air or gas line of 3/4″ to DN 1000

Flow meter insertion type-VA 550Special measurement technology features:

• 4 values on the display: Flow, total consumption, velocity, tem-perature. Units freely adjustable

• All measured values, settings such as gas type, inner diameter, serial number and so on can be accessed via Modbus-RTU

• Comprehensive diagnostic functions readable on the display or remote access via Modbus such as calibration cycle, error codes, serial number

• Notifi cation in case of exceeding the calibration cycle

• Standard version accuracy 1.5% of m.v. ± 0.3% of f.s.

• Precision version accuracy 1.0% of m.v. ± 0.3% of f.s

• Measuring span of 1 : 1000 (0.1 up to 224 m/s)

• Confi guration and diagnosis via display, hand-held device PI 500, PC service software on-site

• Gas type (air, nitrogen, oxygen, argon and so on) freely adjust-able via PC service software or external device DS 400, DS 500, PI 500

• Reference conditions °C and mbar/hPa freely adjustable• Zero-point adjustment, leak fl ow volume suppression

• Pressure loss negligible

 

Flow meter insertion type-VA 550Flow sensor mechanical features:

• Robust impact-proof aluminium die cast housing for the outdoor area IP 67

• All wetted parts made from stainless steel 1.4571

• Suitable as an insertion version for 3/4″ to DN 1000

• On request with DVGW approval for natural gas (up to 16 bar)

• Pressure range up to 50 bar, special version up to 100 bar

• Temperature range up to 180 °C• No moveable parts, no wear

• Sensor tip very robust, easy to clean

• Easy installation and removal under pressure via 1/2″ ball valve

• Housing rotatable, display rotatable by 180°

• Safety ring for installation and removal under pressure

• Depth scale for precise installation

 

Flow meter insertion type-VA 550Flow sensor Optional: Connection to different Bus systems

There are different options available for connection to modern Bus systems:

• Ethernet interface (Modbus-TCP) / PoE

• M-BUS

• Modbus-RTU

• Profi bus DP interface (in process)

• Profi net interface (in process)

• HART (in process)

Vendor Information