PRODUCT DESCRIPTION

High Voltage DC Digital Panel Meter, N30H

The N30H meter is destined for the measurement of d.c. current and d.c. voltage up to 5 A and 600 V.

Characteristic of the N30H meter:

  •  Input:
    •  d.c. current 6 A
    •  d.c. voltage 600 V
  • Output: relay (4), analog (1), digital RS-485/MODBUS (1),
  •  Three-color display – red, green and orange, programmable in three intervals of the  measured value – facilitates the observation of measured quantity changes.
    • digit height: 14 mm
    • highlighted measuring unit
  • Four alarm outputs with signaling on LED diodes operating in 6 different modes,
  • Conversion of any measured optional values into the analog signal 0/4…20 mA or 0…10 V,
  • Storage of minimal and maximal values for all measured quantities,
  • Meter programming from the keyboard or through RS-485 interface by means of the free LPConfig program.
    Parameters which can be reprogrammed:

    • display color, individually in three intervals,
    • thresholds of displayed overflows,
    • precision of displayed results (decimal point),
    • unit highlighting,
    • measurement averaging time,
    • indication recounting (individual characteristic),
    • alarm output parameters,
  • Supply: 85…253 V a.c./d.c. or 20…40 V a.c./d.c.
  • Casing protection grade: IP65
  • Overall dimensions: 96 x 48 x 64 mm

SPECIFICATIONS

Inputs

Input kind

Measuring range

Class

+/- 500 V d.c.

-600..600 V d.c.

0.1

+/- 100 V d.c.

-200..200 V d.c.

0.1

+/- 5 A d.c.

-6..6 A d.c.

0.1

+/- 1 A d.c.

-2..2 A d.c.

0.1

Current time

00.00..23,59

0.5 seconds/h


Outputs

Output kind

Properties

Remarks

Relay output

• 2 x relays, voltageless NO contacts load-carrying capacity 250 V a.c./ 0,5 A a.c.
• 2 x relays, voltageless CO contacts load-carrying capacity 250 V a.c./ 0,5 A a.c.


2 x CO swithed contacts optional

Analog output

• current programmable 0/4..20mA, load resistance ≤ 500 Ω
• voltage programmable 0..10V load resistance ≥ 500 Ω
• Error of output: 0,2% of the set range

optional
Additional error from
temperature change :
50% of the class / 10K

OC output

• OC type, passive npn, 30V d.c./30mA

optional

Auxiliary supply

• 24 V d.c./ 30mA

optional


Digital interface

Interface type

Transmission protocol

Modes

Baud rates

Remarks

RS-485

MODBUS RTU

8N2, 8E1, 8O1, 8N1

4.8, 9.6, 19.2, 38.4 kbit/s

optional


External features

Readout field

5 digit LED display ,
indication range -19999..99999 digit,
height: 14 mm

three-colour display
(colour changes depending on displayed value):
red, green, orange

Weight

< 0.2 kg

 

Dimensions

96 x 48 x 93 mm

Panel cut out: 92+0,6 x 45+0,6 mm

Protection level (acc. to EN 60529)

from frontal side: IP65

from rear side: IP10


Rated operating conditions

Supply voltage

85..253 V a.c./d.c. (40..400Hz) or
20..40 V a.c./d.c. (40..400Hz)

 

Temperature

ambient: -25..23..55 °C

storage: -33..70 °C

Relative humidity

25..95%

condensation inadmissible

Working position

any

 

External magnetic field

0..40..400 A/m

 


Safety and compatibility requirements

Electromagnetic compatibility

Noise immunity

acc. to EN 61000-6-2

Noise emission

acc. to EN 61000-6-4

Insulation between circuits

basic

acc. to EN 61010-1

Pollution degree

2

Installation category

III

Maximal phase-to-earth working voltage

for the supply circuit: 300V

for remaining circuits: 50V

Altitude above sea level

<2000 m

 CONNECTION DIAGRAMS

• 1 A, 5 A – connectors for current measurement on the range 1 A or 5 A
• 100 V, 500 V – connectors for voltage measurement on the range 100 V or 500 V

An example of the N30H meter connection to current measurement is presented on the fig. 2.

However, an example of the meter connection in the configuration for voltage measurement is presented on the fig. 3.

Fig 1. Description of signals on connection strips

Fig. 2. Meter connection in the configuration for current measurement

Fig. 3. Meter connection in the configuration for voltage measurement