HX7.4 3000.H10 Multifunctional Platform Scale | New Radwag Scale
$9,378.77
Multifunctional Stainless Steel Platform Scale, pit version
The HX7.4 3000.H10 Multifunctional Platform Scale is a mechanical design combining into one a PUE HX7 indicator and a 4 load cell platform, both made of stainless steel.
Maximum capacity [Max]: 3000 kg
Readability [d]: 1 kg
Manufacturer: Radwag
Product Code: WP-225-0023
- Description
- Size Guide
- Additional information
- DATASHEET For HX7.4 3000.H10 Multifunctional Platform Scale
- Vendor Info
- More Products
Description
HX7.4 3000.H10 Multifunctional Platform Scale, Stainless Steel & Pit version
The HX7.4 3000.H10 Multifunctional Platform Scale is a mechanical design combining into one a PUE HX7 indicator and a 4 load cell platform, both made of stainless steel. High protection class, IP66 / IP68, makes the HX7 H a scale that can be used in harsh industrial conditions. 4 load cells guarantee correct weighing regardless of load placing at the platform.
The scale provides 7″ colour graphic display and a bar graph consisting of 9 diodes emiting red and green light. The bar graph is a graphic visualisation of the current net weight referred either to the scale range or predetermined min and max thresholds. Housing back is equipped with hermetic communication interfaces such as RS232, RS485, USB, Ethernet, at your disposal there are also digital inputs/outputs and analogue output. This enables cooperation with external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems.
With use of the bracket you can either place the indicator at any flat horizontal surface, or fix it to the wall adjusting the tilt respectively to suit your needs.
The HX7.4 3000.H10 Multifunctional Platform Scale terminal’s software allows carrying out processes such as weighing, parts counting, dosing, labelling, formulations and percent weighing. Indicator’s system of information is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety.
Functions of Radwag HHX7.4 3000.H10 Multifunctional Platform Scale, Stainless Steel
Radwag Accessories for HX7.4 3000.H10 Multifunctional Platform Scale, Stainless Steel Platform Scale, pit version
RADWAG CONNECT FOR Radwag HX7.4 3000.H10 Multifunctional Platform Scale, pit version
The RADWAG Connect is a new tool intended for mobile devices operation of which is based on Windows 10. The program facilitates communication with RADWAG weighing instruments via local network. It enables access to instruments’ basic functions: taring, zeroing, record of weighings, measurements export. The RADWAG Connect uses any stationary or mobile device with Windows 10 operating system installed: desktop computer, laptop, tablet or phone.
Functions:
- establishing communication with all balances, scales and weighing modules using Common Communication Protocol,
- communication via local network,
- support of basic functions: record of current mass, taring, zeroing,
- auto searching for devices,
- connecting with few devices simultaneously, swapping between them,
- clear list of connected platforms (scales),
- record of measurements in the program,
- export of carried out measurements to CSV file,
- work performed using freely selected device with Windows 10 operating system installed: desktop computers, laptops, tablets and phones,
- language versions: Polish and English.
PTO CABLE FOR Radwag HX7.4 3000.H10 Multifunctional Platform Scale / Stainless Steel Platform Scale, pit version
RS 232 cable: scale (HRP, MWSH, MWLH) – computer (with connector for SYS-1544-2415-T3-HRP power supply).
Cable types:
- PT0348.2: 2 m
- PT0348.5: 5 m
- PT0348.10: 10 m
Compatible with:
- HRP platform
- MWSH weighing module
- MWLH weighing module
POWER CABLE FOR HX7.4 3000.H10 Multifunctional Platform Scale / Radwag 4 load cell stainless steel scales
PM02.EX power supply comes in two designs:
- PM02.EX-1-2: power supply intended for operation in hazardous area:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
- PM02.EX-2-2: power supply intended for operation outside hazardous area, equipped with intrinsically safe circuits that can be placed in:
- Zone 1 and 2, where there is a risk of explosion due to mixture of air with vapour, mist or gas, classified as explosion group IIC, IIB and IIA and as temperature class T1, T2, T3, T4.
- Zone 21 and 22, where there is a risk of explosion due to mixture of air with dust, flammable fibres and volatile fuels, classified as explosion group IIIC, IIIB and IIIA.
RADWAG DEVELOPMENT STUDIO SOFTWARE FOR HX7.4 3000.H10 Multifunctional Platform Scale, pit version
The RADWAG Development Studio is a software intended for companies willing to develop their own tools for communication with RADWAG-manufactured weighing equipment. The purpose of RDS is to familiarize customers with solutions used while developing RADWAG communication protocol (Common Communication Protocol). The RDS contains examples of finished code and additional instructions which allow to simplify and accelerate development of new software. The RDS is all a programmer needs to design software that enables error-free communication with our equipment.
Functions:
- Presentation of functions (and subfunctions) of communication protocol (Common Communication Protocol),
- Information on which of the functions are available for balances, scales, weighing modules and terminals,
- Examples of fully-operational source code, ready to be applied in new applications using copy+paste method,
- Connection with weighing equipment on which each function is carried out,
- Packets that are sent and received during operation are presented as text command, in hexadecimal form and in bytes,
- Library with mass control, contained within the development environment, is available for a programmer,
- Complete documentation of the communication protocol,
- Set of instructions regarding other solutions for programmers employed in companies using RADWAG-manufactured equipment,
- Available in English language version.
MOXA UPORT 1110 CONVERTER for HX7.4 3000.H10 Multifunctional Platform Scale, Stainless Steel Platform Scale, pit version
Moxa UPort 1110 converter is a device designed to expand a computer with RS-232 port via USB bus. With this a balance not equipped with the USB interface can be connected to PC.
HX7.4 6000.H9 Multifunctional Platform Scale
Additional information
| Weight | 331.3 kg |
|---|
| Maximum capacity [Max] | 3000 kg |
| Minimum load | 20 kg |
| Readability [d] | 1 kg |
| Tare range | -3000 kg |
| Verification scale interval | 1 kg |
| Max readability for non-verified scale | 200 g |
| OIML Class | III |
| Display | 7” graphic colour |
| Protection class | IP 68 construction, IP 66/68 indicator |
| USB Interface | 1× standard, 1× option |
| ETHERNET Interface | 1× standard |
| EtherNet/IP Interface | 1 × option (RJ45) |
| Profinet Interface | 1 × option (RJ45) |
| RS232 Interface | 1× standard, 1× option |
| 1× option | |
| IN/OUT Interface | 4 IN 4 OUT standard, 12 IN 12 OUT option |
| Modbus RTU module | 1× standard |
| Analog output module (option) | 4-20mA, 0-10V |
| Power supply | 100 ÷ 240 V AC 50 / 60 Hz |
| Power consumption max. | 25 W |
| Optional power supply | 12-24V DC |
| Operating temperature | -10 ÷ +40°C |
| Storage temperature | -10 ÷ +50°C |
| Relative humidity | 10% ÷ 80% RH no condensation |
| Indicator | PUE HX7 |
| Keypad | membrane |
| Number of buttons | 22 |
| Construction | Stal stainless steel AISI304 |
| Weighing pan dimensions | 1500×2000mm |
| Packaging dimensions | 2100×1600×550 mm |
| Net weight | 284.7 kg |
| Gross weight | 331.3 kg |
| Max number of platforms | 2 |