Hydrolysis Unit – HU 6 115V/50-60Hz

Hydrolysis Unit – HU 6 115V/50-60Hz

$4,102.14

Hydrolysis Unit – HU6 115V/50-60Hz

Manufacturer: Velp Scientifica

Part Number: EA-5729-15

SKU: F30310110

Description

HYDROLYSIS UNIT – HU6

Optimum solution for the acid/basic hydrolysis of food and feed samples prior to solvent extraction for total fat analysis.

OVERVIEW

Improves Analysis

  • Hydrolysis / digestion by acid or base
  • Ensures conformity with AOAC standard
  • No sample transfer – no sample loss
  • Crucibles go directly into SER 148

Operator Safety

  • Reduces handling to a minimum
  • Automatic extraction of unwanted fraction
  • No exposure to vapors

Recommendations

  • Select a glassware kit and accessories to match workload
  • Hydrolysis is carried out with hydrochloric acid for approximately 60 minutes at 170 °C.
    The hydrolyzed sample is then filtered in a glass crucible and washed with warm deionized water in order to eliminate the residues of hydrochloric acid

BENEFITS

Preliminary Hydrolysis, Significant Benefits

Perform single or multiple samples at the same time. HU6 is required for a preliminary hydrolysis, both for acid and basic hydrolysis, of food and feed samples prior to solvent extraction with SER Series.

HU6 ensure fast heating and reduced time, with all the benefits of the aluminum block in terms of temperature transmission and homogeneity.

No sample transfer prevents any possible sample loss, as the same crucibles can be processed by the solvent extractor SER.

HU6 needs to be combined with a dedicated glassware to be ready to use.

TECHNICAL SPECIFICATIONS

GENERAL FEATURES
Construction material: epoxy painted stainless steel structure
Number of samples: 6 samples
Set temperature: display visualization
Countdown: display visualization
Display: LCD
Number of programs: 20
Selectable language: I, F, UK, E, D, T
Power: 1350 W
Dimensions (WxHxD): 355x590x450 mm (14.0×23.2×17.7 in)
Weight: 14.5 Kg / 32.0 lb
PERFORMANCE
Temperature range: from room temp. to 200 °C
Temperature calibration: automatic
Stability of the heating block temperature: ± 0,5°C
Homogeneity of the heating block temperature: ± 0,5°C
Precision of the heating block temperature: ± 0,5°C
Reaching of set temperature: acoustic and visual signal

Accessories

Supplied With:

10002412          –         EDPM tube Ø6,4X 11,2mmA00000097        –         Celite, 1 KgA00000089        –         Glass sand, 2 Kg

Optional Accessories

A00000086        –         Glass crucible P1 6pcs/boxA00000087        –         Glass crucible P3 6pcs/boxA00000088        –         Glass bottle for waste collection  A00000144        –         Test tubes Ø 42×300 mm, 250ml 3pcs/boxA00000089        –          Glass sand, 2 KgA00000097        –          Celite, 1 KgA00000085        –          Glassware kit 3 positions for HU 6A00000251        –           IQ/OQ Manual

You've just added this product to the cart: