- Overview:
The basis of the measurement is the antigen-antibody reaction. More than 20 antibodies of seven main toxins are connected to the column concurrently. After the sample is extracted and filtered, it is slowly passed through the immunoaffinity column. The toxins bind to the corresponding antibodies in the column. The immunoaffinity column is then washed to remove other unrelated substances that have not been bound. Elute the toxin with eluent and then inject into the analytical instrument for detection.
Order No. : HCM4210;
Product Properties: AFT B1/B2/G1/G2/M1/M2: 300, FB1/FB2/FB3: 5000, OTA: 100, ST:300, DON/15-ADON: 2000, ZEN: 1000, T-2/HT-2:1000;
Specification: 6mL,10T;
Samples: Grain,feed,etc.
- Components of the kit:
Each kit contains 7 in 1 immunoaffinity columns and 1 instruction manual.
Necessary items not provided in the box:
Equipment
LC-MS/MS
Nitrogen gas evaporator apparatus
Nitrogen gas tank and pressure regulator
Air-pressure controller bracket
Air pump
Balance with 0.01g readability
High-speed homogenizer (maximum speed> 10,000 r/ min) or shaker
Grinder
Sieving screen:2-mm
Graduated cylinder: 100 mL/10 mL
Funnel: 50 mL
Syringe: 10 mL/20 mL
Pipette: 1 mL and pipette tips
Homogenization flask (or 250-mL conical flask with pestle)
Sample bottles and tubes
Rapid qualitative filter paper
Microfiber filter paper (e.g. Whatman 934-AH)
Column holder and syringe connector plug (for use with immunoaffinity columns)
- Reagents
Methanol (CH3OH): Chromatography Grade
Acetic acid (CH3COOH): Analytical Grade
Acetonitrile (CH3CN): Analytical Grade
Sodium chloride (NaCl): Analytical Grade
TWEEN-20 (C58H114O26): Analytical Grade
Sodium hydroxide (NaOH): Analytical Grade
Potassium chloride (KCl): Analytical Grade
Potassium dihydrogen phosphate (KH2PO4): Analytical Grade
Disodium hydrogen phosphate dodecahydrate (Na2HPO4·12H2O): Analytical Grade
Distilled or deionized water
Immunoaffinity Column for Mycotoxins 7-in-1 Combo
$1,074.00
Immunoaffinity Column for Mycotoxins 7-in-1 Combo
Manufacturer Name: Meizheng
Manufacturer No:HCM4210
- Description
- Size Guide
- Additional information
Description
Immunoaffinity Column for Mycotoxins 7-in-1 Combo
Description for Immunoaffinity Column for Mycotoxins 7-in-1 Combo
- The basis of the measurement is the antigen-antibody reaction. More than 20 antibodies of seven main toxins are connected to the column concurrently. After the sample is extracted and filtered, it is slowly passed through the immunoaffinity column. The toxins bind to the corresponding antibodies in the column. The immunoaffinity column is then washed to remove other unrelated substances that have not been bound. Elute the toxin with eluent and then inject into the analytical instrument for detection.Order No. : HCM4210;
Product Properties: AFT B1/B2/G1/G2/M1/M2: 300, FB1/FB2/FB3: 5000, OTA: 100, ST:300, DON/15-ADON: 2000, ZEN: 1000, T-2/HT-2:1000;
Specification: 6mL,10T;
Samples: Grain,feed,etc.