INCUBATOR ST-100S

$862.42

INCUBATOR ST-100S

Dry-air thermostat designed to obtain and maintain a stable temperature required for bacteriological, microbiological, sanitary-bacteriological, virological and biochemical studies. Air thermostats incubators UOSlab PT series is characterized by high reliability in operation. Thermostats are equipped with a modern microprocessor-based temperature control system and the time the alarm about the failure or violation of the thermostat mode.
Material shelves and chamber – stainless steel. Cabinet body – steel with polymer coating.

SKU: EA-989-294

Description

INCUBATOR ST-100S

Dry-air thermostat designed to obtain and maintain a stable temperature required for bacteriological, microbiological, sanitary-bacteriological, virological and biochemical studies. Air thermostats incubators UOSlab PT series is characterized by high reliability in operation. Thermostats are equipped with a modern microprocessor-based temperature control system and the time the alarm about the failure or violation of the thermostat mode.
Material shelves and chamber – stainless steel. Cabinet body – steel with polymer coating.

  • validation port
  • control humidity in the chamber system
  • calibration report
  • metrological certification
  • door lock
  • accent lighting
  • perforated and lattice pans (shelves)
  • interface for connection to a computer and the cabinet work
  • the ability to complete special trays (cassettes)
  • vision panel made of heat-resistant tempered glass
  • stainless steel cabinet housing
  • accelerated drying system
  • heat-recovery system
  • the possibility of non-standard design and special requirements
  • stand on wheels under the cabinet

INCUBATOR ST-100S

Temperature range from 5 °C above room temperature to 200 °C 70
Maximum difference of temperature in chamber volume, °С 0,5
Minimum programmable increment of temperature, °C 0,1
Time requed to heat to 37 °C, min 25
Time requed to heat to 50 °C, min 60
Time requed to heat to 60 °C, min 60
The maximum deviation from the predetermined temperature by volume chamber at 37 ° C, ° C 0,5
The maximum deviation from the predetermined temperature by volume chamber at 50 ° C, ° C 0,5
Uniformity of temperature at 60 ° C, ° C ± 0.5
The recovery time after a 30-second door opening at 60 ° C, sec 30
Power supply, V 220 V
Current frequency, Hz 50 Hz
Power consumption, kW 500
Connection, phases 1~
Number of shelves (standard / max), pcs 2/5
Interior volume, l 102
Number of doors 1
Weight (without load), kg 51,18
Maximum shelf load, kg 14
Internal dimension of chamber (WDH), mm 501×501×410
Overall dimensions (WDH), mm 700×805×697

Vendor Information