INFUSION PUMP 800III

$663.94

INFUSION PUMP 800III

INFUSION PUMP

Model : 800III

Manufacturer: PERLONG MEDICAL EQUIPMENT

PRODUCT FEATURES

  • Real-time infused  volume,
  • Automatic power switching,
  • Mute key, purge, bolus,
  • System memory, key locker
SKU: EA-9225-02

Description

INFUSION PUMP 800III

INFUSION PUMP 800IIIPRODUCT FEATURES

  • Real-time infused   volume,
  • Automatic power switching,
  • Mute key, purge, bolus,
  • System memory, key   locker

 

 

 

 

 

PRODUCT SPECIFICATION OF INFUSION PUMP 800III

Pumping   Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1200 ml/h (in 0.1 ml/h increments)
Purge, Bolus 600-1200 ml/h (in 1 ml/h increments)

Purge when pump stops, bolus when pump starts

Accuracy    ±3%
VTBI 1-20000 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 1-5 ml/h
 

Alarms

Occlusion,   air-in-line, door open, end program, low battery, end battery,

AC power off,   motor malfunction, system malfunction, standby

 

Additional Features

Real-time infused   volume, automatic power switching, mute key, purge, bolus, system memory, key   locker
Occlusion Sensitivity High, medium, low
History Log 30 days
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Vehicle   Power (Ambulance) 12 V
Power   Supply, AC 100-230 V (optional),   50-60 Hz, ≤30 VA
   Battery 12 V, rechargeable
   Battery Life 8 hours at 25 ml/h
   Working   Temperature 10-30℃
   Relative Humidity 30-75%
   Atmospheric Pressure 860-1060 hpa
    Size 150*125*60 mm
   Weight 1.7 kg
Safety Classification Class Ⅱ, type CF

 

Specifications:

Pumping   Mechanism Curvilinear peristaltic
IV Set Compatible with IV sets of any standard
Flow Rate 1-1200 ml/h (in 0.1 ml/h increments)
Purge, Bolus 600-1200 ml/h (in 1 ml/h increments)

Purge when pump stops, bolus when pump starts

Accuracy    ±3%
VTBI 1-20000 ml
Infusion Mode ml/h, drop/min, time-based
KVO Rate 1-5 ml/h
 

Alarms

Occlusion,   air-in-line, door open, end program, low battery, end battery,

AC power off,   motor malfunction, system malfunction, standby

 

Additional Features

Real-time infused   volume, automatic power switching, mute key, purge, bolus, system memory, key   locker
Occlusion Sensitivity High, medium, low
History Log 30 days
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Vehicle   Power (Ambulance) 12 V
Power   Supply, AC 100-230 V (optional),   50-60 Hz, ≤30 VA
   Battery 12 V, rechargeable
   Battery Life 8 hours at 25 ml/h
   Working   Temperature 10-30℃
   Relative Humidity 30-75%
   Atmospheric Pressure 860-1060 hpa
    Size 150*125*60 mm
   Weight 1.7 kg
Safety Classification Class Ⅱ, type CF

 

 

Vendor Information