INSTRUMENT FOR DIN SLOT – S504-pH/RX/T

INSTRUMENT FOR DIN SLOT – S504-pH/RX/T

MANUFACTURER: STEIEL ELETTRONICA Srl

CAT NO: S504-pH/RX/T

SKU: EA-112235-92

Description

INSTRUMENT FOR DIN SLOT – S504-pH/RX/T

Input for pH or ORP electrode + Pt100 sensor

DIN SLOT - S504-pH/RX/T

S504-pH/RX/T is a series of single-measurement instruments, suitable for the installation on DIN slot.
The series includes different models, for measuring pH, ORP, conductivity and a version with mA input.
This instrument is the ideal solution for monitoring water in industrial processes, purification and conditioning, in the agri-food and livestock industry.

TECHNICAL DATA

  • Input for one measurement sensor
  • Input for Pt100 temperature sensor, for measurement and thermo-compensation
  • Power supply 100-240 V~ 50/60 Hz (24 V~ o 24 V- bajo pedido)
  • Two relay outputs configurable as intervention threshold or alarm
  • Current output, fully configurable and galvanically isolated
  • Digital input to disable all outputs
  • Single-language menu, Italian or English
  • Housing with hooking for DIN rail
  • Also available assembled in a closed box, with single or double instrument

Specification

  • Power Supply: 100-240 V~ 50/60 Hz (24 V~, 24 V- upon request)
  • Power Consumption: 4 VA max
  • Protections internal: PTC fuse
  • Environment: storage temperature -20 to +60 °C
    working temperature -10 to +50 °C
    RH max 90% noncondensing
  • Display: 2-row alphanumeric LCD, with backlight
  • Digital Inputs: 1 OFF input for output disabling; accept voltage-free contact; 5 V output power supply at                                  terminals, 5 mA max current;
    1 AUX (auxiliary) input, available on special versions
  • Relay Outputs: 2 independent outputs on 5-pole removable terminal block; contact load max 250 V~, 3 A resistive
  • Current Output: 0-20 or 4-20 mA (selectable through software) on 600 Ω max load, error ma 0.5% FS; electrically insulated
  • Casing: NORYL housing; 6 modules accordingly with DIN 43880 regulation; installation on DIN slot (EN 60715) inside an electrical panel
  • Protection Rate: IP20
  • Dimensions: base 105 x 90 x h 73 mm
  • Weight: approx. 350 g
  • Analogic Inputs: precision better than 0.3% FS; repeatability better than 0.2% FS (electronics only)
  • Temperature Input: 2-pole removable terminal block, for connection of a Pt100 sensor
  • pH / ORP Input 4-pole removable terminal block (coaxial cable + reference); input impedance > 10^12 Ω; standard ranges: 0 … 14.00 pH / ORP ±1000 mV
  • Power Supply: 100-240 V~ 50/60 Hz (24 V~, 24 V- upon request)
  • Power Consumption: 4 VA max
  • Protections internal: PTC fuse
  • Environment: storage temperature -20 to +60 °C
    working temperature -10 to +50 °C
    RH max 90% noncondensing
  • Display: 2-row alphanumeric LCD, with backlight
  • Digital Inputs: 1 OFF input for output disabling; accept voltage-free contact; 5 V output power supply at                                  terminals, 5 mA max current;
    1 AUX (auxiliary) input, available on special versions
  • Relay Outputs: 2 independent outputs on 5-pole removable terminal block; contact load max 250 V~, 3 A resistive
  • Current Output: 0-20 or 4-20 mA (selectable through software) on 600 Ω max load, error ma 0.5% FS; electrically insulated
  • Casing: NORYL housing; 6 modules accordingly with DIN 43880 regulation; installation on DIN slot (EN 60715) inside an electrical panel
  • Protection Rate: IP20
  • Dimensions: base 105 x 90 x h 73 mm
  • Weight: approx. 350 g
  • Analogic Inputs: precision better than 0.3% FS; repeatability better than 0.2% FS (electronics only)
  • Temperature Input: 2-pole removable terminal block, for connection of a Pt100 sensor
  • pH / ORP Input 4-pole removable terminal block (coaxial cable + reference); input impedance > 10^12 Ω; standard ranges: 0 … 14.00 pH / ORP ±1000 mV