INSTRUMENT FOR DIN SLOT – S504-pH/RX/T
INSTRUMENT FOR DIN SLOT – S504-pH/RX/T
MANUFACTURER: STEIEL ELETTRONICA Srl
CAT NO: S504-pH/RX/T
- Description
- Size Guide
- SPECIFICATONS
- DOWNLOADS
Description
INSTRUMENT FOR DIN SLOT – S504-pH/RX/T
Input for pH or ORP electrode + Pt100 sensor
S504-pH/RX/T is a series of single-measurement instruments, suitable for the installation on DIN slot.
The series includes different models, for measuring pH, ORP, conductivity and a version with mA input.
This instrument is the ideal solution for monitoring water in industrial processes, purification and conditioning, in the agri-food and livestock industry.
TECHNICAL DATA
- Input for one measurement sensor
- Input for Pt100 temperature sensor, for measurement and thermo-compensation
- Power supply 100-240 V~ 50/60 Hz (24 V~ o 24 V- bajo pedido)
- Two relay outputs configurable as intervention threshold or alarm
- Current output, fully configurable and galvanically isolated
- Digital input to disable all outputs
- Single-language menu, Italian or English
- Housing with hooking for DIN rail
- Also available assembled in a closed box, with single or double instrument
Specification
- Power Supply: 100-240 V~ 50/60 Hz (24 V~, 24 V- upon request)
- Power Consumption: 4 VA max
- Protections internal: PTC fuse
- Environment: storage temperature -20 to +60 °C
working temperature -10 to +50 °C
RH max 90% noncondensing - Display: 2-row alphanumeric LCD, with backlight
- Digital Inputs: 1 OFF input for output disabling; accept voltage-free contact; 5 V output power supply at terminals, 5 mA max current;
1 AUX (auxiliary) input, available on special versions - Relay Outputs: 2 independent outputs on 5-pole removable terminal block; contact load max 250 V~, 3 A resistive
- Current Output: 0-20 or 4-20 mA (selectable through software) on 600 Ω max load, error ma 0.5% FS; electrically insulated
- Casing: NORYL housing; 6 modules accordingly with DIN 43880 regulation; installation on DIN slot (EN 60715) inside an electrical panel
- Protection Rate: IP20
- Dimensions: base 105 x 90 x h 73 mm
- Weight: approx. 350 g
- Analogic Inputs: precision better than 0.3% FS; repeatability better than 0.2% FS (electronics only)
- Temperature Input: 2-pole removable terminal block, for connection of a Pt100 sensor
- pH / ORP Input 4-pole removable terminal block (coaxial cable + reference); input impedance > 10^12 Ω; standard ranges: 0 … 14.00 pH / ORP ±1000 mV
- Power Supply: 100-240 V~ 50/60 Hz (24 V~, 24 V- upon request)
- Power Consumption: 4 VA max
- Protections internal: PTC fuse
- Environment: storage temperature -20 to +60 °C
working temperature -10 to +50 °C
RH max 90% noncondensing - Display: 2-row alphanumeric LCD, with backlight
- Digital Inputs: 1 OFF input for output disabling; accept voltage-free contact; 5 V output power supply at terminals, 5 mA max current;
1 AUX (auxiliary) input, available on special versions - Relay Outputs: 2 independent outputs on 5-pole removable terminal block; contact load max 250 V~, 3 A resistive
- Current Output: 0-20 or 4-20 mA (selectable through software) on 600 Ω max load, error ma 0.5% FS; electrically insulated
- Casing: NORYL housing; 6 modules accordingly with DIN 43880 regulation; installation on DIN slot (EN 60715) inside an electrical panel
- Protection Rate: IP20
- Dimensions: base 105 x 90 x h 73 mm
- Weight: approx. 350 g
- Analogic Inputs: precision better than 0.3% FS; repeatability better than 0.2% FS (electronics only)
- Temperature Input: 2-pole removable terminal block, for connection of a Pt100 sensor
- pH / ORP Input 4-pole removable terminal block (coaxial cable + reference); input impedance > 10^12 Ω; standard ranges: 0 … 14.00 pH / ORP ±1000 mV