Insulation Resistance Meter MIC-15K1

$4,924.35

INSULATION RESISTANCE METER

MODEL: MIC-15K1

MANUFACTURER: SONEL

Insulation resistance meter MIC-15KV features:

• Partial discharge indicator PDI.
• Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD.
• It allows testing the electrical durability of the tested object – breakdown voltage indication.
• High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and in close
proximity to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
• The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility
and to carry out a partial location of their occurrence.
• Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location
of cables and wires short circuit using one of the following:
• visual method (if power cables are visible along the entire length),
• reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault
(the conductor must be buried in the ground with earth direct contact).
• Compatible with external software.

 

SKU: AME-7199-3

Description

 SONEL MIC-15K1 Insulation Resistance Meter

MIC-15k1 Insulation resistance meter is designed to measure insulation resistance of power objects, i.e.:
• single- and multi-core cables,
• transformers,
• motors and generators,
• capacitors, switches and other devices installed in power stations.

It is especially recommended for measurements in areas with very high electromagnetic disturbances, e.g. electrical substations with 1200 kV AC and 500 kV DC. Thanks to the 15 kV measuring voltage (in accordance with ANSI / NETA ATS-2009 TABLES 100.1) the insulation resistance meter can be used for measuring objects with a nominal voltage above 34.5 kV.

Highly efficient HV inverter, with test voltage of 15 kV and current up to 10 mA, suitable for measuring the insulation resistance up to 40 TΩ. Achieving such a result makes these insulation resistance meters unrivalled devices. Three-wire resistance measurement, performed using a “GUARD” wire, eliminates surface leakage currents caused by contaminated insulation, thereby increasing the reliability of obtained results.

The insulation resistance meter indicates the Dielectric Absorption Ratio DAR, Polarization Index PI and the value of Dielectric Discharge DD. The insulation resistance meter allows user to assess the condition of the insulation, by applying the test voltage incrementally in steps (SV – Step Voltage) or smoothly (RampTest – RT).
• SV method ensures that a dielectric in good condition will provide the same
results, regardless of the applied voltage.
• RT method allows to determine the characteristics of the insulating material.

The insulation resistance meter smoothly increases the measuring voltage without exposing the object to so-called electrical stress. It records the time and voltage value at which the electrical breakdown of the insulation took place. Built-in digital filters, with averaging time of 10, 30, 60, 100, 200 sec. guarantee stable measurement results in areas of strong electromagnetic interference.

A very useful solution is the function that allows to Burnout the damaged object. In case of exposed cables, it enables visual identification of the fault location. In the case of shielded cables, the method allows to generate a seismic acoustic wave from the place of damage.

In special conditions, an energetic discharge will appear cyclically. By using the geophone it will be possible to precisely pinpoint the place where such a discharge occurs. Burnout feature allows also locating transient faults (appearing, for example, only during rainfall) with the support of reflectometry, and in case of a short
circuit (of a screen or return wire) to the ground – applying the method of measuring voltage drop (the A-frame).

The Insulation resistance meter automatically saves the measurement results. The number of auto save points depends on the amount of data, which is saved within the main memory.

15 kV 40 TΩ

 

FEATURES OF THE MIC-15K1 INSULATION RESISTANCE METER

• Partial discharge indicator PDI.
• Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD.
• It allows testing the electrical durability of the tested object – breakdown voltage indication.
• High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and in close
proximity to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
• The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility
and to carry out a partial location of their occurrence.
• Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location
of cables and wires short circuit using one of the following:
• visual method (if power cables are visible along the entire length),
• reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault
(the conductor must be buried in the ground with earth direct contact).
• Compatible with external software.

TECHNICAL INFORMATION FOR MIC-15K1 INSULATION RESISTANCE METER

>Insulation resistance measurement
Measuring range according to IEC 61557-2
UN = 15 000 V: 50 kΩ…40.0 TΩ
Measurement with DC and increasing voltage (SV) for UISO = 15 kV

Range Resolution Accuracy
0,0…999 kΩ 1 kΩ ±(3% m.v. + 10 digits)
1,00…9,99 MΩ 0,01 MΩ ±(3% m.v. + 10 digits)
10,0…99,9 MΩ 0,1 MΩ ±(3% m.v. + 10 digits)
100…999 MΩ 1 MΩ ±(3% m.v. + 10 digits)
1,00…9,99 GΩ 0,01 GΩ ±(3% m.v. + 10 digits)
10,0…99,9 GΩ 0,1 GΩ ±(3% m.v. + 10 digits)
100…999 GΩ 1 GΩ ±(3,5% m.v. + 10 digits)
1,00…9,99 TΩ 0,01 TΩ ±(7,5% m.v. + 10 digits)
10,0…20,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)
10,0…40,0 TΩ 0,1 TΩ ±(12,5% m.v. + 10 digits)

>Ranges of measured resistance depending on the test voltage

Voltage UISO Measuring range
50 V 200 GΩ
100 V 400 GΩ
250 V 1,00 TΩ
500 V 2,00 TΩ
1000 V 4,00 TΩ
2500 V 10,00 TΩ
5000 V 20,0 TΩ
10 000 V 40,0 TΩ
15 000 V 40,0 TΩ

>Capacitance measurement

Range Resolution Accuracy
0…999 nF 1 nF ±(5% m.v. + 5 digits)
1,00…49,99 µF 0,01 µF ±(5% m.v. + 5 digits)
  • Displaying measured capacity after RISO measurement
  • For measurement voltages below 100 V the measurement error is not specified

>TECHNICAL SPECIFICATION FOR MIC-15K1 INSULATION RESISTANCE METER

type of insulation acc. to EN 61010-1 and IEC 61557 double
measurement category acc. to EN 61010-1 IV 1000 V (operating altitude ≤2000 m) IV 600 V (operating altitude ≤3000 m)
ingress protection acc. to EN 60529 IP67 (IP40 for closed case)
resistance to external interference voltages up to 1550 V
resistance to external interference currents up to 10 mA
advanced, digital filtering of interferences 10 / 30 / 60 / 100 / 200 seconds
test leads lock yes
power supply Li-Ion 14.8 V rechargeable battery from network 90 V ÷ 260 V, 50 Hz/60 Hz
dimensions 390 x 308 x 172 mm
weight ca. 6.3 kg
storage temperature 25ºC…+70ºC
operating temperature -20ºC…+50ºC
humidity 20%…90%
operating altitude ≤3000 m
reference temperature +23ºC ± 2ºC
reference humidity 40%…60%
display graphical LCD
number of RISO measurements with battery power supply min. 1000 acc. to EN 61557-2
data transmission USB and Bluetooth
quality standard ISO 9001 compliant

The MIC-15K1 Insulation resistance meter meets the requirements of standards EN 61010-1 and IEC 61557 and the product meets EMC requirements (immunity for industrial environment) with accordance to standards EN 61326-1 and EN 61326-2-2.

 

Additional information

Weight 6.3 kg