KD-TS1A Automated Tissue Processor (Mini-type)
$4,462.00
MANUFACTURER: KEDEE
MODEL NO: KD-TS1A Automated Tissue Processor
- Description
- Size Guide
- TECHNICAL SPECIFICATIONS
- Vendor Info
- More Products
Description
KD-TS1A Automated Tissue Processor (Mini-type)
Economical, reagent saving, practical design with small footprint and low cost
Two sets of operating programs and two sets of time-extending programs; all built-in programs have memory function
Single-chip computer control technology allows a complete set of functions
Well-sealed plexiglass cover with gas-effluxion mechanism, environmentally friendly and safe
Large-capacity reagent cup: more than 40 tissue specimens can be processed simultaneously
Not affected by short blackouts or power outages during operation
Manual adjustment can be conducted anytime during the programmed automatic operation; afterwards, the system automatically enters the programmed operation
Internal dry heating mechanism with high-precision temperature control
Two-dimensional, flexible transmission system, low noise, wear-resistant
High-precision photoelectric positioning control system to ensure reliable operation and precise positioning
Fully intelligent design, enabling timely determination and recovery from an abnormal event
Approximately 40 tissue samples can be processed at the same time
Capacity of Each Cup: 750 ml
Length of Processing Time in the Cup:
Any length between 0 and 99 hours for the first cup
Any length between 0 and 24 hours for the other cups
Temperature Range: RT – 80℃
Dripping Time: Approximately 30 s
Frequency of Agitation: 2 times/minute
Tissue Protection Cup: at the 7th station
Working Voltage: AC220V±10% 50Hz (standard model) AC110V±10% 60Hz
Power Requirements: 500 W
Heating Control: heating automatically begins when the tissue enters the 2nd cup, thus avoiding unnecessary energy waste
Dimensions: 795×435×415 mm (W×D×H)
Weight: 50kg
Number of Cups: 12 (9 for reagents, 3 for paraffin)
Capacity of Each Cup: 750 ml
Length of Processing Time in the Cup:
Any length between 0 and 99 hours for the first cup
Any length between 0 and 24 hours for the other cups
Temperature Range: RT – 80℃
Dripping Time: Approximately 30 s
Frequency of Agitation: 2 times/minute