-15%

L100 PeCOD® Laboratory / Portable Chemical Oxygen Demand (COD) Analyser

Original price was: $10,540.00.Current price is: $8,999.00.

PeCOD®  L100 Laboratory / Portable Chemical Oxygen Demand (COD) Analyser

Manufacturer: Mantech Inc

P/N: PeCOD L100

Includes: 2 sensors, MANTECH software and USB cable.

NOTE: For Portable use please also order P/N: PQA-85000 (battery pack) and P/N: PQA-80006 (carry case) separately

 

SKU: EA-7728-01-2

Description

L100 PeCOD® Laboratory/Portable Chemical Oxygen Demand (COD) Analyser

DESCRIPTION

L100 PeCOD® Laboratory/Portable COD Analyser for fast and simple COD measurements with no hazardous reagents required.

MANTECH’s revolutionary L100 PeCOD® Analyser technology provides accurate chemical oxygen demand (COD) results in 15 minutes — without the use of harmful chemicals including dichromate and mercury. Highly adaptable for wastewater and drinking water applications, the PeCOD® Analyzer’s patented nanotechnology-based approach to COD analysis will save you time and money while protecting the environment and the health and safety of your workers.

BENEFITS

  • Real time results (less than 15 mins ) to overcome the problems of time delays encountered by chemical oxidation methods
  • Absolute COD measurement avoiding costly and time consuming regular calibration
  • Complete oxidation leading to high accuracy and high reproducibility minimizing matrix variation problems
  • Direct signal acquisition resulting in high sensitivity and wide linear range
  • Equivalent BOD
  • No Hazardous reagents
  • Light weight < 2kg and rugged making it easy to transport
  • Splash resistant touch pad
  • Optional battery pack for field use

APPLICATIONS

  • Industrial & Municipal Wastewater
  • Pulp & Paper
  • Food & Beverage
  • Drinking Water
  • Research and Laboratory

ADVANTAGES OF L100 peCOD  ANALYSER

Faster, accurate results

peCOD is the fastest available method for quantifying chemical oxygen demand (COD), providing operators with real time data needed to make timely, impactful decisions that enhance environmental protection while generating substantial savings on chemical and energy use.

Safe, green chemistry

peCOD nanotechnology provides a higher oxidizing power and none of the risks associated with harmful chemicals such as dichromate and mercury used in traditional COD analysis. It’s safe and simple to use for any laboratory or operations staff member at any point in the process.

The core of the technology is the peCOD sensor, which consists of a UV-activated nanoparticle TiO2 (titanium dioxide) photocatalyst coupled to an external circuit. When a sample is introduced into the microcell containing the peCOD sensor, the TiO2 is irradiated by UV light, and a potential bias is applied. The UV light creates a photohole in the TiO2 sensor with a very high oxidizing power and organics in the cell are oxidized. peCOD is extremely accurate across a broad range of organics. The powerful oxidizing potential of UV-illuminated TiO2 ensures that virtually all species will be fully oxidized giving a true measure of COD.

Strong correlation to BOD5

The PeCOD® COD Analyzer technology is a proven performer in a variety of municipal and industrial wastewater applications. Recent studies have shown a strong correlation between the 10 minute peCOD method for testing chemical oxygen demand (COD) and standard dichromate COD (CODCR) and five-day BOD (BOD5) methods. In most cases, peCOD can be used as a BOD screening tool, providing accurate BOD estimates in just minutes versus several days.

Trusted by governments

The PeCOD® COD Analyzer will be the technology of choice as new regulations take effect in Europe in September 2017 that will eliminate the use of dichromate in COD testing. peCOD conforms to Method E3515, released in 2014 by the Ontario Ministry of Environment and Climate Change (MOECC) to replace the dichromate method for COD testing. peCOD is also included as an approved alternate COD method in the Protocol for the Sampling and Analysis of Industrial/Municipal Wastewater which was updated in 2016 by the MISA (Municipal Industrial Strategy for Abatement) program.

One technology, multiple configurations

The PeCOD® COD Analyzer is available in a variety of configurations that use the same innovative technology and method. peCOD combines robust performance and flexibility to suit the needs of your laboratory or process operations.

L100 PeCOD® Chemical Oxygen Demand (COD) Analyser

BENEFITS

Faster, accurate results

peCOD is the fastest available method for quantifying chemical oxygen demand (COD), providing operators with real time data needed to make timely, impactful decisions that enhance environmental protection while generating substantial savings on chemical and energy use.

Safe, green chemistry

peCOD nanotechnology provides a higher oxidizing power and none of the risks associated with harmful chemicals such as dichromate and mercury used in traditional COD analysis. It’s safe and simple to use for any laboratory or operations staff member at any point in the process.

The core of the technology is the peCOD sensor, which consists of a UV-activated nanoparticle TiO2 (titanium dioxide) photocatalyst coupled to an external circuit. When a sample is introduced into the microcell containing the peCOD sensor, the TiO2 is irradiated by UV light, and a potential bias is applied. The UV light creates a photohole in the TiO2 sensor with a very high oxidizing power and organics in the cell are oxidized. peCOD is extremely accurate across a broad range of organics. The powerful oxidizing potential of UV-illuminated TiO2 ensures that virtually all species will be fully oxidized giving a true measure of COD.

Strong correlation to BOD5

The PeCOD® COD Analyzer technology is a proven performer in a variety of municipal and industrial wastewater applications. Recent studies have shown a strong correlation between the 10 minute peCOD method for testing chemical oxygen demand (COD) and standard dichromate COD (CODCR) and five-day BOD (BOD5) methods. In most cases, peCOD can be used as a BOD screening tool, providing accurate BOD estimates in just minutes versus several days.

Trusted by governments

The PeCOD® COD Analyzer will be the technology of choice as new regulations take effect in Europe in September 2017 that will eliminate the use of dichromate in COD testing. peCOD conforms to Method E3515, released in 2014 by the Ontario Ministry of Environment and Climate Change (MOECC) to replace the dichromate method for COD testing. peCOD is also included as an approved alternate COD method in the Protocol for the Sampling and Analysis of Industrial/Municipal Wastewater which was updated in 2016 by the MISA (Municipal Industrial Strategy for Abatement) program.

One technology, multiple configurations

The PeCOD® COD Analyzer is available in a variety of configurations that use the same innovative technology and method. peCOD combines robust performance and flexibility to suit the needs of your laboratory or process operations.

L100 PeCOD®  Chemical Oxygen Demand (COD) Analyser

 

MANTECH_Brochure_PeCOD_051717_WEB

 

MAN-MD-P-0407-02-PeCOD-Benchtop-L100-Operation-Manual