Milk Tylosin and Tilmicosin Rapid Test Strip
$210.29
Milk Tylosin and Tilmicosin Rapid Test Strip
Manufacturer Name: Meizheng
Manufacturer No: JC0089
- Description
- Size Guide
- SPECIFICATION
Description
Milk Tylosin and Tilmicosin Rapid Test Strip
Description for Milk Tylosin and Tilmicosin Rapid Test Strip
The Tylosin/Tilmicosin Rapid Test Kit is a Lateral Flow assay that determines the residues for the presence of tylosin/tilmicosin residues in raw milk.
Background:
Tylosin/Tilmicosin is a macrolide antibiotic mainly used to prevent livestock and poultry pathogens and mycoplasma infections. The detection of veterinary drug residues such as tylosin/tilmicosin in raw milk is of great concern for the dairy industry because of the potential interfering and adverse effects of antibiotic residues frequently found in raw milk.
Manufacturer | Meizheng |
Trademark | Anticfast® |
Order No. | JC0089 |
Analyte | Tylosin/Tilmicosin |
Sample Type | Raw cow’s milk |
Methodology | Colloidal Gold Immunochromatography Lateral Flow Assay |
Packaging | 96 Tests |
Storage | The kits should be stored at a dry place away from the sunlight and the storage temperature is 2-8˚C. DO NOT FREEZE! |
Shelf life | The validity for this kit is 12 months |
Lead time | Shipped within 5-12 working days. |
Application | This test is designed for on-site rapid detection or daily control in laboratories. |
Limit of Detection (μg/kg=ppb):
Antibiotic | EU MRL (μg/kg) | LOD (μg/kg) |
Tylosin | 50 | 20 |
Tilmicosin | 50 | 20 |
Kits Contents:
No. | Name | Specs | Remark |
1 | Test strips | 12×8 strips | 96 strips in total |
2 | Microwells | 12×8 wells | 96 wells in total |
3 | Positive control | 1 | Tylosin: 20ppb |
4 | Negative control | 1 | |
5 | Pipette | 1 | |
6 | Pipette tips | 100 | |
7 | Microwell holder | 1 | |
8 | QR code | 1 | Optional |
Materials Required But Not Provided:
No. | Name | Remark |
1 | Micropipette | |
2 | Timer | |
3 | Incubator | Optional |
4 | Strip Reader | Optional |
Manufacturer | Meizheng |
Trademark | Anticfast® |
Order No. | JC0089 |
Analyte | Tylosin/Tilmicosin |
Sample Type | Raw cow’s milk |
Methodology | Colloidal Gold Immunochromatography Lateral Flow Assay |
Packaging | 96 Tests |
Storage | The kits should be stored at a dry place away from the sunlight and the storage temperature is 2-8˚C. DO NOT FREEZE! |
Shelf life | The validity for this kit is 12 months |
Lead time | Shipped within 5-12 working days. |
Application | This test is designed for on-site rapid detection or daily control in laboratories. |