NoiseBadge Personal Noise Dosemeter System (Model 22)

$2,084.05

NoiseBadge Personal Noise Dosemeter System (Model 22)

Manufacturer: Pulsar

Cat No: Model 22-1

SKU: EA-11671-84

Description

NoiseBadge Personal Noise Dosemeter System (Model 22)

NoiseBadge Personal Noise Dosemeter System (Model 22)

Measurement System with 1 dosemeter

Simply and accurately assess and capture noise dose and the true noise exposure of workers using the Pulsar NoiseBadge Personal Noise Dosemeter System. The UK Health and Safety Executive (HSE) recommends that employers should obtain a reliable estimate of employees’ exposures, and compare the exposure with the exposure action values and limit values. This dosimeter badge system is just the device to do this.

  • The revolutionary dosimeter badge is a self-contained noise measurement device, also known as Personal Sound Exposure Meter (PSEM), that has no cables, displays or controls, making it the perfect solution for noise dosimetry, because units cannot be tampered with easily or damaged during measurements.
  • A separate Decibel Reader unit communicates with the dosemeters and controls the programming, calibration, start-stopping, data logging, downloading and storing of measurements. All key measurement parameters can be viewed on its large clear backlit LCD display screen, which also displays a time history graph of worker’s daily noise exposure over an entire working day.
  • The Reader contains an integral acoustic calibrator allowing the dosemeter to be calibrated prior to and following each noise measurement in accordance with international regulations; the dosemeter automatically achieves this by computing the Daily Exposure for European legislation or the Time Weighted Average for US-based legislation.
  • Full ‘Time History’ information allows you to determine when key noise problems occur during a worker’s day.
  • Collect all the data essential to meet compliance with occupational noise regulations at the touch of a button including LAeq, LEP,d, % Dose and TWA. 
  • Frequency weightings include ‘A’ weighted (range 70dB(A) to 130dB(A)). The additional ‘C’ frequency weighted peak Time History allows you to fully assess risks from impulsive noise in the workplace.
  • Our effective, user-friendly software package, AnalyzerPlus, allows users to quickly analyse and transform the raw data into informative report formats, simplifying a potentially complex and time-consuming process.
Specifications

Applicable Standards

Model 22 NoiseBadge Dosemeter Measurement System

IEC 61252:1993 Personal Sound Exposure Meters

ANSI S1.25:1991 Personal Noise Dosimeter

Model 22-R Reader Unit

Internal Acoustic Calibrator to IEC 60942:2001 Class 2

 

Measurement Range (Typical)

70dB(A) to 130dB(A) RMS

120dB(C) to 140dB(C) Peak

Measurement Functions

  • Dosemeter Configuration
  • Calibration Record
  • Measurement Duration
  • Highest Peak(C) Sound Level
  • Overload Exceedence
  • Battery Status
  • 115dB(A) Maximum Sound Level Exceedence

One-Minute Time History of:

  • LAeq (3dB) or LAVG (4dB or 5dB)
  • Peak(C) Level
  • Battery Level

For 3dB Exchange Rate

  • LAeq, LEX,8h, LAE, % Dose, Exposure (Pa2h),
  • Estimated % Dose,
  • Estimated Exposure (Pa2h)

For 4dB & 5dB Exchange Rates

  • LAVG, TWA, % Dose, Estimated % Dose

Weightings

Frequency:

‘A’ for all RMS measurements.

‘C’ for Peak Sound Pressure

 

Dosemeter Configuration

Independent User Configuration of:

Exchange Rate: 3dB, 4dB or 5dB

Criterion Level: 80dB, 85dB, 87dB, 90dB

Criterion Time: 8hrs, 12hrs, 16hrs, 18hrs

Threshold: None, 80dB, 85dB, 90dB

Time Weighting: None, ‘S’ (Slow)

Memory

The Model 22-R Reader Unit can store the following measurement data:

Up to 93 measurement of 8 hours duration

Up to 64 measurements of 12 hours duration

Up to 33 measurements of 24 hours duration

Power

Internal NiMH Battery with intelligent charging system

Model 22-R Reader

2 x AA/LR6 with Auto Power Switch Off

Chargers Units

PS22 Mains Power Supply

 

Output

Model 22 Dosemeter Measurement System

Infrared to Model 22-R Reader Unit

Model 22-R Reader

USB 2.0 (which also provides power to the 22-R Reader)

 

Dimensions

Microphone Apex Ø13.0mm, Base Ø47mm, Height 38mm

Weight

Model 22 doseBadge 45gms (1.6oz)

Model 22-R Reader 400gms (14oz)

Environmental

Operating Temperature -10oC to +50oC

Storage Temperature -20oC to +60oC

Humidity up to 95% RH Non-Condensing

 

Software

AnalyzerPlus supplied as standard

 

Ordering Codes

The Model 22 Dosemeter System can be provided as a complete

measurement system with the following order codes:

Model 22-1 Dosemeter Measurement System with 1 dosemeter

Model 22-2 Dosemeter Measurement System with 2 dosemeters

Model 22-5 Dosemeter Measurement System with 5 dosemeters

Model 22-10 Dosemeter Measurement System with 10 dosemeters

The measurement kits contain the Model 22 dosemeters units and fixing mounts, a Model 22-R Reader Unit, CHR22 Charger Unit (where X = 2,5 or 10), PS 22 Power Supply, K3 Hard Attache Case, USB Cable, Software, Batteries, User Manuals & Certificates of Calibration.

Warranty

The Model 22 Dosemeter systems are supplied with a

24 month warranty.

Vendor Information