NOVOTEST UD3701 flaw detector

$3,933.20

Ultrasonic Flaw Detector NOVOTEST UD3701

SKU: AME-97-03

Description

Ultrasonic  NOVOTEST UD3701 Flaw Detector

The Ultrasonic Flaw Detector NOVOTEST UD3701 is designed to detect internal defects, such as discontinuities and heterogeneities of materials in products and welds, determine coordinates and evaluate defect parameters, measure thickness and the velocity of propagation and attenuation of ultrasonic waves in the materials (metals, plastics, glass and etc.), the search for places of corrosion, cracks, internal delamination and other defects.

Ultrasonic Flaw Detector NOVOTEST UD3701 is a universal, powerful, functional, ergonomic and reliable device for solving tasks of ultrasonic flaw detection both in the laboratory and in the field.

Advantages of NOVOTEST UD3701 Flaw detector

  • Superbright, touch display with which it is comfortable to work outdoors on a sunny day;
  • Automatic calculation of the delay in the probe;
  • Frequency range from 0 to 10 MHz, with smooth adjustment;
  • Display of a scale of scanning in microseconds and millimeters;
  • The presence in the device of the operating mode of the DAC and TVG curves (up to 16 points);
  • The presence in the flaw detector of the DGS control mode, with automatic calculation of the equivalent reflector zone;
  • Carrying out settings both using the touch screen and by keyboard;
  • The presence of movable blocks of output of measured values, so it can be located in any part of the A-scan;
  • Archive of measurements, settings, probes with the ability to transfer data to a PC;
  • Simulation of a measurement from a stored record in the device memory
Operating frequency range from 1 to 10,0 MHz
Range of measured time intervals (duration of scanning) from 6 to 1000 µs
Velocity range 1000 – 9999 m / s
Error of measurement of time intervals not exceed ± 0,025 µs
Maximum permissible error of measurement of the amplitudes of the signals at the receiver input in the range from 0 to 110 dB not exceed ± 0,5 dB
Testing gain range 125 dB
Averaging over the quantity of starts from 1 to 16
Range of variation of temporal sensitivity adjustment (TVG) 40 dB
Number of control points TVG 16
Duration of the excitation pulse to the load from 0,0 to 0,5 µs
Deviation of the amplitudes of input signals in the range from 10 to 100% of the screen height not more than 1 dB
Setting a delay in the prism of the probe from 0 to 15 µs
Detection of signals positive half-wave, radio mode
Dimensions (W*H*L) 140 mm x 210 mm x 55 mm
Weight, not more 1,5 kg