Nuc Scout, 3 x 3, IP65

$23,850.60

Nuc Scout,3 x 3, IP65

MANUFACTURER: SARAD GmbH

REF NO: 11017013

 

 

 

SKU: EA-1278-7

Description

Nuc Scout, 3 x 3, IP65

 

Nuc Scout,3 x3,IP65

Applications:
• the detection of radioactive sources by disposal companies or security forces
• the assessment of large-scale contamination based on geographic information
systems (GIS)
• monitoring measurements of food and building materials
• in nuclear medicine
Features:
• the local dose rate and the activities of 28 user-definable individual nuclides can
be measured over long periods of time
• large, bright touchscreen
• adjustable time interval with spectrum
• integrated GPS receiver for local assignment of the measurement data
• internal wireless network interface for sending measurement data to a base
station up to several hundred meters away (optional)
• detachable 2 x 2“ NaI(Tl) detector for flexible positioning
• optional measuring table for Marinelli cups
• activity calculation of the individual nuclides with PSV algorithm and trapezoidal
method
• the scope of delivery includes an extensive software package for the transfer,
display and export of the measurement data. The software allows full remote
operation of the device via USB or a wireless network

 

Detector                                NaI(Tl) with integrated photo multiplier and HV supply

Detector size                    2“ x 2“, optional 3” x 3”

Energy range                   25 keV – 3 MeV

Resolution                       < 7,5 % (7 % typ.) @ 662 keV

GAMMA PROBE:

Efficiency

 

net count rate > 1100 cps / (µSv/h) for Cs-137
Max. count rate

 

100.000 cps
Dose rate range

 

0 … 15 µSv/h for Cs-137
Spectrum

 

512 channels
Results single shot or over time

identification of up to 28 emission lines in four nuclide lists; nuclide-lists can be either created by user (based on a library) or loaded as pre-defined list

calculation of net activity based on pre-defined or user created efficiency calibrations

energy compensated local dose rate measurement

 

Stabilization electronic temperature stabilization, peak-pickup by PSV

analysis algorithm

General

 

Sampling cycles                storage of up to 16 different measurement programs

(defined or infinite repetition) with intervals from 1s     to weeks

predefined cycles: 10s, 30s, 60s continuous and

5min, 15min, single shot

 

Data storage                     SD-Card to store more than 780.000 data records

 

Display                            touch screen 6cm x 9cm with back light, good readable even in direct sunlight shows: status/results/spectra                                          

 

Interfaces                         USB and optional NetMonitors (ZigBee)

 

Power supply                   18V mains adapter / NiMH battery with int. charger opration: min. 8h (typ.14h)

 

Dimensions                      265 mm x 195 mm x 210 mm

 

Weight                               2,5 kg

 

Rating                                IP65

 

Scope of delivery                USB cable, charger, transport case, SW and manual(electronic version), calibration certificate

Alert                                      buzzer 85dB, red LED, display turns on automatically showing the reason of alert

GPS                                        SIRF 3 (12 channels), GPS coordinates are recorded and stored together with measurement results

GIS compatible KML files can be exported and opened with Google Earth

NetMonitors                        frequency 2,4 GHz, power rate 100 mW protocol IEEE 802.15.4(range>300m in case of intervisibility
wireless
network interface
(ZigBee Standard)

Optional accessories          Sampling table for usage with Marinelli beaker (standard or version with lead shield and scale),charger, USB  cable, transportation                                                      case, NetMonitors network coordinator (connected via USB to PC) & instrument adapter

Software (included in delivery)         device control and data transfer, visualization, data management,calibration, libraary management, export of KLM files for direct   opening by Google Earth dCONFIG: SYSTEM configuration, creation of sample cycle

General

 

Sampling cycles                storage of up to 16 different measurement programs

(defined or infinite repetition) with intervals from 1s                                               to weeks

predefined cycles: 10s, 30s, 60s continuous and

5min, 15min, single shot

 

Data storage                     SD-Card to store more than 780.000 data records

 

Display                            touch screen 6cm x 9cm with back light, good readable even in direct sunlight shows: status/results/spectra                                          

 

Interfaces                         USB and optional NetMonitors (ZigBee)

 

Power supply                   18V mains adapter / NiMH battery with int. charger opration: min. 8h (typ.14h)

 

Dimensions                      265 mm x 195 mm x 210 mm

 

Weight                               2,5 kg

 

Rating                                IP65

 

Scope of delivery                USB cable, charger, transport case, SW and manual(electronic version), calibration certificate

Alert                                      buzzer 85dB, red LED, display turns on automatically showing the reason of alert

GPS                                        SIRF 3 (12 channels), GPS coordinates are recorded and stored together with measurement results

GIS compatible KML files can be exported and opened with Google Earth

NetMonitors                        frequency 2,4 GHz, power rate 100 mW protocol IEEE 802.15.4(range>300m in case of intervisibility
wireless
network interface
(ZigBee Standard)

Optional accessories          Sampling table for usage with Marinelli beaker (standard or version with lead shield and scale),charger, USB  cable, transportation                                                      case, NetMonitors network coordinator (connected via USB to PC) & instrument adapter

Software (included in          device control and data transfer, visualization, data management,calibration, libraary management, export of KLM files for direct                                                       opening by Google Earth dCONFIG: SYSTEM configuration, creation of sample cycle
delivery)