PRESSURE CONTROLLER / ADT780S-3K-AP300R

$21,760.28$27,208.90

Pressure Controller

Product Model: ADT780S-3K-AP300R

Manufacturer: Additel

Features of the ADT780S-3K-AP300R  pressure controller:

  • Pressure sensor ranges from  0 to 315 psi/  0 to 21 bar
  • Accuracy is 0.01% rdg or 0.003% FS whichever is greater
  • Removable interchangeable intelligent sensors
  • Standalone solution to 1,000 psi (70 bar), no gas bottle required when used with the Electric Pump
  • Standard model accuracy of 0.003% of full scale
  • WiFi enabled communications
  • Fully temperature compensated accuracy over 0°C to 50°C
  • HART Communication and Profibus PA
  • Large 7” color touch screen display
  • Control stability of 0.003%FS (Full Scale)
  • Easy-to-use icon based user interface.
  • Internal and External use.
SKU: N/A
Clear

Description

ADDITEL Pressure Controller ADT780S-3K-AP300R

For years, Additel has provided the most durable, accurate, quality pressure controllers for field applications. The Additel 780 controller incorporates the same durability, accuracy, and quality into a new bench top controller packed with features and functionality that is remarkably easy to use.

The Additel 780 pressure controller offers two base ranges: to 1000 psi (70 bar) and to 3000 psi (200 bar). The base range establishes the maximum controlling range of the controller.

Each configuration includes a control sensor in which you can pre-select the sensor range best suited your application. External and internal sensors can be used which allows for expanded range and accuracy capability in the future.

There are also two types that can be selected: the Additel 780S device is the standard controller option without any measurement capability. The Additel 780 device has expanded functionality including electrical measurement and HART and Profibus PA communication.

Each unit comes with one Intelligent Pressure Module configured to the many range offerings provided. Standard accuracy sensors (ADT160A-CPXXX) are silicon pressure sensors with a 1 year accuracy of 0.02% FS. The precision quartz based sensors improve the 1 year accuracy specification to 0.005% of reading + 0.005% FS.

Each sensor has been specially aged, tested and screened before assembly. After assembly each sensor is temperature compensated over the range of -10°C to 50°C. The Additel 780 device allows for one internal pressure sensor and one external pressure sensor.

The modular design of this pressure controller provides for interchangeability of both the internal and external sensors with other Intelligent Pressure Modules. In addition to the Intelligent Pressure Modules, the Additel 780 device has a built in barometric sensor. This allows for switching between gauge pressures to absolute pressures.

 

ADT780-3K-AP3KQ-B2 PRESSURE CONTROLLER

Standalone solution of the Pressure controller ADT780S-3K-AP300R

Typical pressure controllers will require a nitrogen bottle for  the gas supply which makes it difficult to move the controller around without having to move or connect another bottle. The Additel 780 pressure controller is unique in that with the optimal electric pump, you can generate pressure to 1000psi (70bar) without the need of a gas bottle.

 

TECHNICAL SPECIFICATIONS FOR ADT780S-3K-AP300R

-PHYSICAL SPECIFICATIONS FOR PRESSURE CONTROLLER ADT780S-3K-AP300R

Power 100 to 240V, 50/60 Hz
Pressure ports G1/8 F
Storage temperature  -20°C to 70°C
Operating environment 0-90% RH non-condensing
Display 7 inch (17.8 cm) color, touch screen display
Weight 33 lbs (15 kg)
Dimensions (DWH) 16.5 x 17.3 x 5.2 inch (419 x 440 x 132 mm)
Mounting  Standard desktop, optional rack mount kit
Shock 4G
Vibration 1G 10Hz~500Hz

 

-MEASUREMENT SPECIFICATIONS FOR PRESSURE CONTROLLER ADT780S-3K-AP300R

Pressure range -14.5 to 3,000 psi (-0.95 to 200 bar)
Control stability 0.003% FS (stability based on % FS of control sensor range)
Precision (includes 1 year stability) See pressure range table
Media Clean gas
Over-range indication 103% to 120% (based on sensor)
Resolution 4, 5, 6, or 7 digits (user selectable)[2]
Pressure type Gauge, Absolute
Warm up time 15 minutes
Measurement units Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, kg/m2, kg/cm2, mtorr, torr, atm, lb/ft2, tsi, user selectable
Minimum control pressure 0.001 psi

Standard Accessories for Pressure Controller ADT780S-3K-AP300R

  • ADT127-X External Manifold
  • Manifold connection hose
  • Power adapter
  • 9060 Pressure module connection cable
  • Adapter set (adapters to fit the ADT78X port to male fittings)
  • CD Manual
  • ISO17025 accredited certificate
  • O-rings
  • Vacuum/Vent tubing

Additional information

FITTING SIZE

B (1/4BSP F), B-HABP (1/4BSP F) with high accuracy barometer, B2 (1/2BSP F), B2-HABP (1/2BSP F) with high accuracy barometer, M (M20X1.5 F), M-HABP (M20X1.5 F) with high accuracy barometer, N (1/4NPT F), N-HABP (1/4NPT F) with high accuracy barometer, N2 ( 1/2NPT F), N2-HABP ( 1/2NPT F) with high accuracy barometer