Pressure module, -380 to 1K inH2O (-950 to 2.5K mbar), 0.02%FS accuracy
$2,767.00
MANUFACTURER: ADDITEL
MODEL NO: ADT155-02-DP150
Pressure module, -380 to 1K inH2O (-950 to 2.5K mbar), 0.02%FS accuracy
- Description
- Size Guide
- SPECIFICATION
- DATA SHEET
- Vendor Info
- More Products
Description
Pressure module, -380 to 1K inH2O (-950 to 2.5K mbar), 0.02%FS accuracy
Pressure module, -380 to 1K inH2O (-950 to 2.5K mbar), 0.02%FS accuracy
| Gauge Pressure [1] | |||||
|---|---|---|---|---|---|
| P/N | Pressure Range | Media [2] | Accuracy(%FS) | Burst Pressure | |
| (psi) | (bar) | ||||
| V15 | -15 | -1 | G | 0.02 | 3× |
| GP2 | 2 | 0.16 | G | 0.05 | 3× |
| GP5 | 5 | 0.35 | G | 0.05 | 3× |
| GP10 | 10 | 0.7 | G | 0.02 | 3× |
| GP15 | 15 | 1 | G | 0.02 | 3× |
| GP30 | 30 | 2 | G | 0.02 | 3× |
| GP50 | 50 | 3.5 | G , L | 0.02 | 3× |
| GP100 | 100 | 7 | G , L | 0.02 | 3× |
| GP150 | 150 | 10 | G , L | 0.02 | 3× |
| GP300 | 300 | 20 | G , L | 0.02 | 3× |
| GP500 | 500 | 35 | G , L | 0.02 | 3× |
| GP600 | 600 | 40 | G , L | 0.02 | 3× |
| GP1K | 1000 | 70 | G , L | 0.02 | 3× |
| GP1.5K | 1500 | 100 | G , L | 0.02 | 3× |
| GP2K | 2000 | 140 | G , L | 0.02 | 3× |
| GP3K | 3000 | 200 | G , L | 0.02 | 3× |
| GP5K | 5000 | 350 | G , L | 0.02 | 3× |
| GP10K | 10000 | 700 | G , L | 0.02 | 2× |
| GP15K | 15000 | 1000 | G , L | 0.05 | 2x |
| GP20K | 20000 | 1400 | G , L | 0.05 | 1.5x |
| GP25K | 25000 | 1600 | G , L | 0.05 | 1.5x |
| GP30K | 30000 | 2000 | G , L | 0.05 | 1.5x |
| GP36K | 36000 | 2500 | G , L | 0.05 | 1.5x |
| GP40K | 40000 | 2800 | G , L | 0.05 | 1.35x |
| GP50K | 50000 | 3500 | G , L | 0.1 | 1.2x |
| GP60K | 60000 | 4200 | G , L | 0.1 | 1.1x |
| [1]. Sealed gauge pressure for above 1000 psi | |||||
| [2]. G=Gas, L=Liquid | |||||
| Differential Pressure | ||||||
|---|---|---|---|---|---|---|
| P/N | Pressure Range[1] | Media | Accuracy (%FS) | Burst Pressure | Static Pressure Range | |
| (inH20) | (mbar) | |||||
| DP1 | ±1 | ±2.5 | G | 0.05[2] | 100× | ±10 psi |
| DP2 | ±2 | ±5.0 | G | 0.05[2] | 100× | ±10 psi |
| DP5 | ±5 | ±10 | G | 0.05[2] | 50× | ±10 psi |
| DP10 | ±10 | ±25 | G | 0.05[2] | 20× | ±10 psi |
| DP20 | ±20 | ±50 | G | 0.05 | 20× | ±10 psi |
| DP30 | ±30 | ±75 | G | 0.05 | 20× | ±10 psi |
| DP50 | ±50 | ±160 | G | 0.05 | 3× | ±10 psi |
| DP100 | ±100 | ±250 | G | 0.02 | 3× | ±15 psi |
| DP150 | ±150 | ±350 | G | 0.02 | 3× | 50 psi |
| DP300 | ±300 | ±700 | G | 0.02 | 3× | 50 psi |
| [1] FS specification applies to the span of the range. Accuracy includes 1 year stability. | ||||||
| [2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability. | ||||||
| Compound Pressure | ||||||
|---|---|---|---|---|---|---|
| P/N | Pressure Range | Media | Accuracy | Pressure Rating | ||
| psig | bar.g | Burst | Over Pressure | |||
| CP2 | ±2 | ±0.16 | G | 0.05% FS | 3x | 1.2x |
| CP5 | ±5 | ±0.35 | G | 0.02% FS | 3x | 1.2x |
| CP10 | ±10 | ±0.7 | G | 0.02% FS | 3x | 1.2x |
| CP15 | ±15 | ±1.0 | G | 0.02% FS | 3x | 1.2x |
| CP30 | -15 to 30 | -1 to 2.0 | G | 0.02% FS | 3x | 1.2x |
| CP50 | -15 to 50 | -1 to 3.5 | G | 0.02% FS | 3x | 1.2x |
| CP100 | -15 to 100 | -1 to 7.0 | G,L | 0.02% FS | 3x | 1.2x |
| CP300 | -15 to 300 | -1 to 20 | G,L | 0.02% FS | 3x | 1.2x |
| CP500 | -15 to 500 | -1 to 35 | G,L | 0.02% FS | 3x | 1.2x |
| CP600 | -15 to 600 | -1 to 40 | G,L | 0.02% FS | 3x | 1.2x |
| CP1K | -15 to 1,000 | -1 to 70 | G,L | 0.02% FS | 3x | 1.2x |
| CP2K | -15 to 2,000 | -1 to 140 | G,L | 0.02% FS | 3x | 1.2x |
| CP3K | -15 to 3,000 | -1 to 200 | G,L | 0.02% FS | 3x | 1.2x |
| CP5K | -15 to 5,000 | -1 to 350 | G,L | 0.02% FS | 3x | 1.2x |
| CP10K | -15 to 10,000 | -1 to 700 | G,L | 0.02% FS | 2x | 1.2x |
| Absolute Pressure | |||||
|---|---|---|---|---|---|
| P/N | Pressure Range | Media | Accuracy(%FS) | Burst Pressure | |
| (psi) | (bar) | ||||
| AP5 | 5 | 0.35 | G | 0.1 | 3× |
| AP10 | 10 | 0.7 | G | 0.1 | 3× |
| AP15 | 15 | 1 | G | 0.1 | 3× |
| AP30 | 30 | 2 | G | 0.1 | 3× |
| AP50 | 50 | 3.5 | G | 0.1 | 3× |
| AP100 | 100 | 7 | G , L | 0.05 (0.1) | 3× |
| AP300 | 300 | 20 | G , L | 0.05 (0.1) | 3× |
| AP500 | 500 | 35 | G , L | 0.05 (0.1) | 3× |
| AP1K | 1000 | 70 | G , L | 0.05 (0.1) | 3× |
| AP3K | 3000 | 200 | G , L | 0.05 (0.1) | 3× |
| Barometric Pressure | |||||
|---|---|---|---|---|---|
| P/N | Pressure Range | Media | Accuracy | Burst Pressure | |
| Low | High | ||||
| BP | 60 kPa | 110 kPa | G | 40 Pa | 3× |
| Precision Sensors[1] [3] – Absolute Pressure | ||||||
|---|---|---|---|---|---|---|
| P/N | Pressure Range | Media | Accuracy[2] | Pressure Rating | ||
| psi.a | bar.a | Burst | Over Pressure | |||
| AP15R | 15 | 1 | G | 0.01% FS | 2x | 1.2x |
| AP30R | 30 | 2 | G | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP50R | 50 | 3.5 | G | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP100R | 115 | 8 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP300R | 315 | 21 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP500R | 515 | 36 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP1KR | 1015 | 71 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 2x | 1.2x |
| AP2KR | 2015 | 141 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 3x | 1.1x |
| AP3KR | 3015 | 201 | G,L | 0.01% rdg or 0.003% FS whichever is greater | 3x | 1.1x |
| AP6KQ | 6000 | 400 | G,L | 0.01% FS | 3x | 1.2x |
| AP10KQ | 10000 | 700 | G,L | 0.01% FS | 2x | 1.2x |
| AP15KQ | 15000 | 1000 | G,L | 0.01% FS | 2x | 1.2x |
| AP20KQ | 20000 | 1400 | G,L | 0.01% FS | 2x | 1.2x |
| AP30KQ | 30000 | 2000 | G,L | 0.02% FS | 1.5x | 1.1x |
| [1] Contact Additel for other range options. | ||||||
| [2] Accuracy includes calibration uncertainty, linearity and long-term stability | ||||||
| [3] Precision Sensors (APXR and APXQ) cannot be configured as an Ex model and cannot be read by Ex device. | ||||||
| Additel 226Ex with ADT161Ex Pressure Module | |||||
|---|---|---|---|---|---|
| Standard Accuracy | Precision Accuracy | ||||
| CPXXX | DPXXX | GPXXX | APXXQ | APXXR | |
| Operating temperature | -10°C to 50°C (14°F to 122°F) | 15°C to 25°C (59°F to 77°F) | 10°C to 30°C (50°F to 86°F) | ||
| Storage temperature | -20°C to 70°C (-4°F to 158°F) | -20°C to 70°C (-4°F to 158°F) | |||
| Relative humidity | 95% RH | 90% RH | |||
| Pressure connections (for external use only) | 1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15 | 1/4NPT, 1/2NPT, 1/4BSP, 1/2BSP, M20x15 | |||
| Enclosure (for external use only) | SS enclosure | SS enclosure | |||
| Intrinisic Safety (ADT161Ex models only) | ATEX certified intrinsically safe II 1G EX ia IIC T4 Ga TUR 16.0023X | N/A | |||
| Dimensions (Dia x H) | 33 mm x 123 mm (1.3” x 4.84”) | Depends on the model | 44 mm x 195 mm (1.7” x7.7”) | ||
| Weight | 0.4 kg (0.99 lb) | Depends on the model | 0.7 kg (1.5 lb) | ||
| Warranty | 1 Year | 1 Year | 1 Year | ||
Vendor Information
-
Furnaces, Ovens and Accessories, Instrumentation Products, Laboratory Instruments
1200°C Muffle Furnace with lift door, Tmax LT 24/12
Price range: $9,070.19 through $10,423.41Select options This product has multiple variants. The options may be chosen on the product pageQuick View -