Pressure module, -380 to 800 inH2O (-950 to 2K mbar), 0.02%FS accuracy

$2,767.00

MANUFACTURER: ADDITEL

MODEL NO: ADT155-02-DP400

Pressure module, -380 to 800 inH2O (-950 to 2K mbar), 0.02%FS accuracy

 

SKU: AME-11171-156

Description

Pressure module, -380 to 800 inH2O (-950 to 2K mbar), 0.02%FS accuracy

Pressure module, -380 to 800 inH2O (-950 to 2K mbar), 0.02%FS accuracy

Description for Pressure module, -380 to 800 inH2O (-950 to 2K mbar), 0.02%FS accuracy

OVERVIEW

With advanced microprocessor technology and state-of-the-art silicon pressure sensors, Additel’s 161 and 161Ex series Digital Pressure Modules provide an accurate, reliable, and economic solution for wide range of pressure applications. Our intrinsically safe (Ex) models are up to the task of providing the best possible results, even in hazardous environments. In order to reach the best performance, every silicon pressure sensor in the module has been specially aged, tested and screened before assembly. Designed as external pressure modules for Additel’s 760 automatic handheld pressure calibrator, the ADT761 automated pressure calibrator, ADT226/ADT227 series handheld process calibrator and Additel’s flagship 780 pressure controller, the Additel 161 is unmatched in performance and reliability. If intrinsic safety is a critical requirement for your workload, we have you covered when you combine our model ADT226Ex/ADT227Ex process calibrator with any of our ADT161Ex pressure modules.

 

GENERAL FEATURES

 

• Gauge pressure measurement accuracy of 0.02% FS
Absolute Pressure measurement accuracy of 0.1% FS

• Pressure ranges to 60,000 psi (4,200 bar)

• Advanced temperature compensation

• NIST traceable calibration and data included

Gauge Pressure [1]
P/N Pressure Range Media [2] Accuracy(%FS) Burst Pressure
(psi) (bar)
V15 -15 -1 G 0.02
GP2 2 0.16 G 0.05
GP5 5 0.35 G 0.05
GP10 10 0.7 G 0.02
GP15 15 1 G 0.02
GP30 30 2 G 0.01 (0.02) 3× [3]
GP50 50 3.5 G , L 0.01 (0.02) 3× [3]
GP100 100 7 G , L 0.01 (0.02) 3× [3]
GP150 150 10 G , L 0.01 (0.02) 3× [3]
GP300 300 20 G , L 0.01 (0.02) 3× [3]
GP500 500 35 G , L 0.01 (0.02) 3× [3]
GP600 600 40 G , L 0.01 (0.02) 3× [3]
GP1K 1000 70 G , L 0.01 (0.02) 3× [3]
GP1.5K 1500 100 G , L 0.01 (0.02) 3× [3]
GP2K 2000 140 G , L 0.01 (0.02) 3× [3]
GP3K 3000 200 G , L 0.01 (0.02) 3× [3]
GP5K 5000 350 G , L 0.01 (0.02) 3× [3]
GP10K 10000 700 G , L 0.01 (0.02) 2× [4]
GP15K 15000 1000 G , L 0.05 2x
GP20K 20000 1400 G , L 0.05 1.5x
GP25K 25000 1600 G , L 0.05 1.5x
GP30K 30000 2000 G , L 0.05 1.5x
GP36K 36000 2500 G , L 0.05 1.5x
GP40K 40000 2800 G , L 0.05 1.35x
GP50K 50000 3500 G , L 0.1 1.2x
GP60K 60000 4200 G , L 0.1 1.1x
[1]. Sealed gauge pressure for above 1000 psi
[2]. G=Gas, L=Liquid
[3] 2x for 0.01% FS
[4] 1.2x for 0.01% FS
Note: 0.01%FS accuracy sensors cannot be configured as Ex models and cannot be read by Ex devices.

 

Differential Pressure
P/N Pressure Range[1] Media Accuracy (%FS) Burst Pressure Static Pressure Range
(inH20) (mbar)
DP1 ±1 ±2.5 G 0.05[2] 100× ±10 psi
DP2 ±2 ±5.0 G 0.05[2] 100× ±10 psi
DP5 ±5 ±10 G 0.05[2] 50× ±10 psi
DP10 ±10 ±25 G 0.05[2] 20× ±10 psi
DP20 ±20 ±50 G 0.05 20× ±10 psi
DP30 ±30 ±75 G 0.05 20× ±10 psi
DP50 ±50 ±160 G 0.05 ±10 psi
DP100 ±100 ±250 G 0.02 ±15 psi
DP150 ±150 ±350 G 0.02 50 psi
DP300 ±300 ±700 G 0.02 50 psi
[1] FS specification applies to the span of the range. Accuracy includes 1 year stability.
[2] 0.05%FS accuracy (incl 6 months stability). One year accuracy is 0.05%FS calibration accuracy combined with 0.05%FS one year stability.

 

Compound Pressure
P/N Pressure Range Media Accuracy Pressure Rating
psig bar.g Burst Over Pressure
CP2 ±2 ±0.16 G 0.05% FS 3x 1.2x
CP10 ±10 ±0.7 G 0.02% FS 3x 1.2x
CP15 ±15 ±1.0 G 0.02% FS 3x 1.2x
CP30 -15 to 30 -1 to 2.0 G 0.01 (0.02) % FS 3x 1.2x
CP50 -15 to 50 -1 to 3.5 G 0.01 (0.02) % FS 3x 1.2x
CP100 -15 to 100 -1 to 7.0 G,L 0.01 (0.02) % FS 3x 1.2x
CP150 -15 to 150 -1 to 10 G,L 0.01 (0.02) % FS 3x 1.2x
CP300 -15 to 300 -1 to 20 G,L 0.01 (0.02) % FS 3x 1.2x
CP500 -15 to 500 -1 to 35 G,L 0.01 (0.02) % FS 3x 1.2x
CP600 -15 to 600 -1 to 40 G,L 0.01 (0.02) % FS 3x 1.2x
CP1K -15 to 1,000 -1 to 70 G,L 0.01 (0.02) % FS 3x 1.2x
CP2K -15 to 2,000 -1 to 140 G,L 0.01 (0.02) % FS 3x 1.2x
CP3K -15 to 3,000 -1 to 200 G,L 0.01 (0.02) % FS 3x 1.2x
CP5K -15 to 5,000 -1 to 350 G,L 0.01 (0.02) % FS 3x 1.2x
CP10K -15 to 10,000 -1 to 700 G,L 0.01 (0.02) % FS 2x 1.2x
Note: 0.01%FS accuracy sensors cannot be configured as Ex models and cannot be read by Ex devices.

 

Precision Sensors [1]
P/N Pressure Range Media Accuracy [2] Burst Pressure Over Pressure
(psi) (bar)
AP15R (absolute) 0 to 15 0 to 1 G 0.01% FS 1.2x
CP30M -15 to 30 -1 to 2.0 G, L 0.005% rdg + 0.005% FS 1.2x
CP50M -15 to 50 -1 to 3.5 G, L 0.005% rdg + 0.005% FS 1.2x
CP100M -15 to 100 -1 to 7.0 G, L 0.005% rdg + 0.005% FS 1.2x
CP300M -15 to 300 -1 to 20 G, L 0.005% rdg + 0.005% FS 1.2x
CP500M -15 to 500 -1 to 35 G, L 0.005% rdg + 0.005% FS 1.2x
CP1KM -15 to 1,000 -1 to 70 G, L 0.01% rdg or 0.003% fs, whichever is greater 1.2x
CP2KM -15 to 2,000 -1 to 140 G, L 0.01% rdg or 0.003% fs, whichever is greater 1.1x
CP3KM -15 to 3,000 -1 to 200 G, L 0.01% rdg or 0.003% fs, whichever is greater 1.1x
CP5KM -15 to 5,000 -1 to 350 G, L 0.01% rdg or 0.003% fs, whichever is greater 1.1x
CP10KM -15 to 10,000 -1 to 700 G, L 0.01% rdg or 0.003% fs, whichever is greater 1.2x 1.1x
[1] Contact Additel for other range options.
[2] Accuracy includes calibration uncertainty, linearity, and long-term stability
Note: Precision Sensors (CPXM) cannot be configured as Ex models and cannot be read by Ex devices.

 

Barometric Pressure
P/N Pressure Range Media Accuracy Burst Pressure
Low High
BP 60 kPa 110 kPa G 55 Pa

 

Additel 226Ex with ADT161Ex Pressure Module
  Standard Accuracy Precision Accuracy
CPXXX DPXXX GPXXX APXXR
Operating temperature -10°C to 50°C (14°F to 122°F) 10°C to 30°C (50°F to 86°F)
Storage temperature -30°C to 70°C (-22°F to 158°F) -30°C to 70°C (-22°F to 158°F)
Relative humidity 95% RH 90% RH
Pressure connections (for external use only) 1/4NPT, 1/2NPT, 1/4BSP, 1/2BPS, M20x15
Enclosure (for external use only) SS enclosure
Intrinisic Safety (ADT161Ex models only) ATEX certified intrinsically safe II 1G EX ia IIC T4 Ga (ADT161Ex modules only work together with ADT226Ex or ADT227Ex to conform to the ATEX certificate)
Dimensions (Dia x H) 33 mm x 123 mm (1.3” x 4.84”)
Weight 0.4 kg (0.99 lb)
Warranty 1 Year