Radon Scout Home
$1,084.38
Radon scout home
MANUFACTURER: SARAD GmbH
REF NO: 11014022
- Description
- Size Guide
- SPECIFICATION
- DOCUMENT
Description
Radon Scout Home
Description of radon scout home
The Radon Scout Home is used for long-term monitoring of the legal reference value for the radon concentration in breathing air. The device was specially designed for homeowners as well as tenants, lessors and housing companies.
The Radon Scout Home records the transient behaviour of the radon concentration over many years reliably, meaning that influences on weather conditions and seasonal changes are safely recorded. Sensors for temperature and humidity provide information about a healthy indoor climate. The measurement data can be read out at any time for preservation of evidence.
The instrument is manufactured and calibrated in our factory in Dresden/Germany. Calibration certificates are available on request and at additional cost.
Applications:
for long-term monitoring of the radon concentration in airborne Radon (222
Rn) in homes and workplaces
for homeowners as well as tenants, lessors and housing companies.
Features:
reliably records the time course of the radon concentration over many years
temperature and humidity sensors provide information about a healthy room
climate
the measurement data can be read out at any time to preserve evidence
a CO2 sensor is optional
can be calibrated according to DIN EN ISO/IEC 17025:2018 on request.
Applications:
- for long-term monitoring of the radon concentration in airborne Radon (222 Rn) in homes and workplaces
- for homeowners as well as tenants, lessors and housing companies.
Features:
- reliably records the time course of the radon concentration over many years
- temperature and humidity sensors provide information about a healthy room climate
- the measurement data can be read out at any time to preserve evidence
- a CO2 sensor is optional
- can be calibrated according to DIN EN ISO/IEC 17025:2018 on request.
Radon measurement | ||
Detector type | silicon detector | |
Range | 1 Bq/m3 … 1.000.000 Bq/m³
CO2: 400 … 5.000 ppm (0,04% … 0,5%) |
|
Accuracy | 20% | |
Sensitivity | 0,092 cpm/(kBq/m³) | |
Stat. error (1) | 1 week @ 300 Bq/m³
1 month @ 300 Bq/m³ 1 week @ 100 Bq/m³ 1 month @ 100 Bq/m³ 24 hours @ 300 Bq/m³ |
6%
3% 10% 5% 15% |
Internal sensors | Rel. humidity, temperature,
optional bar. pressure (-P) or CO2 (-CO2) |
Important | opt.CO2 sensor works only when instrument is powered through USB connector (computer, AC/DC adapter, power bank); measurement of other parameters is not affected, Automatic calibration with respect to outdoor CO2 level |
Equipment | ||
Environmental conditions | 0 … 40°C
0 … 95% rF, non-condensing 800 … 1.100 hPa |
|
Power supply
|
3.3 V DC by 2 x AAA batteries or via USB socket (5 V) running time with battery approx. 5 … 6 months “Low. Batt.” Display with red LED (flashes once every four seconds)
short-term buffering of the real-time clock when changing the battery
|
Display alpha numeric LCD with bright backlight
Languages DE, EN, ES, FR, IT, NO Displayed values switchable between SI and US units |
|
average radon value since the start of a series of measurements
average radon level for the last 24 hours temperature, relative humidity barometric pressure (Radon Scout Home – P) CO2 concentration (Radon Scout Home – CO2) battery voltage (Radon Scout Home – P/CO2) date and time |
|
Data storage | non-volatile memory with circular structure
16.383 data records saves all parameters including tilt detection each 4hrs |
Interface | USB (Mini-USB socket) |
Alert indication | display with red LED (flashes four times every four seconds) at > reference value of 300 Bq/m³ at a CO2 concentration of more than 1,000 ppm, the red backlight is switched on (only Radon
Scout Home – CO2) |
Operation | slide switch to start/stop sampling button to toggle display page and backlight |
Software | Radon Vision |
Dimensions | 80 mm x 96 mm x 44 mm |
Weight | 150 g (incl. batteries) |
Scope of delivery | USB cable (for all types) 2 batteries type AAA quick manual & software on www.sarad.de power adapter (for CO2 version only) |
DAkkS-accredited calibration according to DIN EN ISO/IEC 17025:2018 possible on request
Radon measurement | ||
Detector type | silicon detector | |
Range | 1 Bq/m3 … 1.000.000 Bq/m³
CO2: 400 … 5.000 ppm (0,04% … 0,5%) |
|
Accuracy | 20% | |
Sensitivity | 0,092 cpm/(kBq/m³) | |
Stat. error (1) | 1 week @ 300 Bq/m³
1 month @ 300 Bq/m³ 1 week @ 100 Bq/m³ 1 month @ 100 Bq/m³ 24 hours @ 300 Bq/m³ |
6%
3% 10% 5% 15% |
Internal sensors | Rel. humidity, temperature,
optional bar. pressure (-P) or CO2 (-CO2) |
Important | opt.CO2 sensor works only when instrument is powered through USB connector (computer, AC/DC adapter, power bank); measurement of other parameters is not affected, Automatic calibration with respect to outdoor CO2 level |
Equipment | ||
Environmental conditions | 0 … 40°C
0 … 95% rF, non-condensing 800 … 1.100 hPa |
|
Power supply
|
3.3 V DC by 2 x AAA batteries or via USB socket (5 V) running time with battery approx. 5 … 6 months “Low. Batt.” Display with red LED (flashes once every four seconds)
short-term buffering of the real-time clock when changing the battery
|
Display alpha numeric LCD with bright backlight
Languages DE, EN, ES, FR, IT, NO Displayed values switchable between SI and US units |
|
average radon value since the start of a series of measurements
average radon level for the last 24 hours temperature, relative humidity barometric pressure (Radon Scout Home – P) CO2 concentration (Radon Scout Home – CO2) battery voltage (Radon Scout Home – P/CO2) date and time |
|
Data storage | non-volatile memory with circular structure
16.383 data records saves all parameters including tilt detection each 4hrs |
Interface | USB (Mini-USB socket) |
Alert indication | display with red LED (flashes four times every four seconds) at > reference value of 300 Bq/m³ at a CO2 concentration of more than 1,000 ppm, the red backlight is switched on (only Radon
Scout Home – CO2) |
Operation | slide switch to start/stop sampling button to toggle display page and backlight |
Software | Radon Vision |
Dimensions | 80 mm x 96 mm x 44 mm |
Weight | 150 g (incl. batteries) |
Scope of delivery | USB cable (for all types) 2 batteries type AAA quick manual & software on www.sarad.de power adapter (for CO2 version only) |