Reciprocating Cylinder Dissolution System

$39,670.00

Reciprocating Cylinder Dissolution System (Manual Sampling)

Manufacturer: Raytor

Ref No: RT3

 

SKU: EA-1211-24

Description

Reciprocating Cylinder Dissolution System

Manual Sampling

Description of Reciprocating Cylinder Dissolution System (Manual Sampling)

Manufactured for precise dissolution tests with automated samples and filtering mechanisms is the RT3-AT Reciprocating Cylinder Dissolution System. This unit has an integrated coaxial bracket that enables fast mount replacements for holders alongside automatic vessel lids that protect against evaporation over time. The design incorporates a single-piece water bath which provides uniform heating properties and full drainage. The equipment operates with a high-precision sampling pump as well as an advanced Teflon pipeline system which prevents sample adsorption and maintains accurate results. Users can adjust the parameters for reciprocating stroke position alongside rate immersion duration and drainage duration according to FDA 21 CFR Part 11 standards.

Specification of Reciprocating Cylinder Dissolution System (Manual Sampling)

Reciprocating Cylinder Dissolution System


Length ×Width× Height(Fully Raised): 80cm × 63cm ×100 cm Dissolution Vessel Row Number: 7 tubes×6 Rows (300mL Stand Vessel)
Dissolution System Level: ≤ 0.3° Shaft Verticality: ≤ 90°± 0.5°
Temperature Control Range: Room Temperature ~ 50℃ Temp. Resolution: 0.1 ℃
Temp. Accuracy: ≤ ± 0.2℃ Vessels Temp. Difference: ≤ ± 0.5℃
Adjustable Range of Reciprocating Stroke: 2 ~ 10 cm Error of Reciprocating Stroke: ≤ ± 0.1 cm
Adjustable Range of Reciprocating Rate: 4 ~ 60 DPM Error of Reciprocating Rate: ≤ ±5%
Maximum Running Time: 600 (Hours)

Automatic Sampling Workstation


Maximum Settable Sampling Number: 30 Times Maximum Sampling Volume: 1~10ml
Sampling Precision: ≤±1% Sample Collector: Suitable for 10ml Test Tube or HPLC Vial

Operating System


Meeting FDA21 CFR Part 11

Reciprocating Cylinder Dissolution System


Length ×Width× Height(Fully Raised): 80cm × 63cm ×100 cm Dissolution Vessel Row Number: 7 tubes×6 Rows (300mL Stand Vessel)
Dissolution System Level: ≤ 0.3° Shaft Verticality: ≤ 90°± 0.5°
Temperature Control Range: Room Temperature ~ 50℃ Temp. Resolution: 0.1 ℃
Temp. Accuracy: ≤ ± 0.2℃ Vessels Temp. Difference: ≤ ± 0.5℃
Adjustable Range of Reciprocating Stroke: 2 ~ 10 cm Error of Reciprocating Stroke: ≤ ± 0.1 cm
Adjustable Range of Reciprocating Rate: 4 ~ 60 DPM Error of Reciprocating Rate: ≤ ±5%
Maximum Running Time: 600 (Hours)

Automatic Sampling Workstation


Maximum Settable Sampling Number: 30 Times Maximum Sampling Volume: 1~10ml
Sampling Precision: ≤±1% Sample Collector: Suitable for 10ml Test Tube or HPLC Vial

Operating System


Meeting FDA21 CFR Part 11

Vendor Information

  • Address: