Solvent Extractors – SER 148/6 Series 115V/50-60Hz

$12,609.12

Solvent Extractors, 230V/50-60Hz – Series 148 /6

Manufacturer: Velp Scientifica

Part Number: EA-5729-10

SKU: F30310242

Description

SOLVENT EXTRACTOR – SER 148 Series

Solvent Extractors – SER 148/6 Series 115V/50-60Hz

Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique.

OVERVIEW

Beats Ordinary Soxhlet Extractor

  • Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent)
  • Low solvent consumption (high solvent recovery, up to 75%)
  • Limited cost per analysis

Convenience & Choice

  • Select from 29 on-board empty programs
  • Two models available to match sample load
    SER 148/3, a 3-position solvent extraction system
    SER 148/6, a 6-position solvent extraction system

Operator Safety

  • IP 55 protection from particles and liquids

Recommendations

  • Combine with HU 6 (Velp Hydrolysis Unit) for high density samples

BENEFITS

Solvent Extractor – Applications and HU6 Hydrolysis Unit

Solvent extraction is used for determination of different substances present in products related to agriculture, industry or in environmental samples.

SER Series can be used, according to official methods, for determining fats, tensides, plasticizers and pesticides on many matrices, including food and feed samples, detergents, rubber and plastic formulates, and many others.

No sample transfer, coming from HU6 Hydrolysis Unit, prevents any possible sample loss, as crucibles can also be used on the two units.

Solvent Extractors – Randall Method, Faster Results

Perform single or multiple solvent extractionswith Randall method, an improvement of Soxhlet technique, as hot solvents are used to speed up the analysis.
In fact, the fast solubilization made by hot solvent permits a considerable reduction of the extraction time (approx. 90 minutes).

The extraction is made by immersion of the sample in the boiling solvent, followed by a rinsing phase with cold solvent.

Maximum reproducibility is ensured, as well as a high recovery rate of the solvent used.

SER Series can be used with a wide range of sample types and with a variety of solvents, forincreased flexibility.

TECHNICAL SPECIFICATIONS

GENERAL FEATURES
Construction material: epoxy painted stainless steel structure
Number of samples: SER 148/3 3 positions
SER 148/6 6 positions
2 Displays: working temperature / settable parameters
Dimensions (WxHxD): SER 148/3 480x620x390 mm (18.9×24.4×15.4 in)
SER 148/6 700x620x390 mm (27.6×24.4×15.4 in)
Weight: SER 148/3 30 Kg (66 lb)
SER 148/6 40 Kg (88 lb)
Power: SER 148/3 500 W
SER 148/6 950 W
PERFORMANCE
Reproducibility (RSD): ≤ 1%
Solvent recovery: from 50 to 75%
Max volume extraction cup: 150 ml
Number of programs: 29
Working temperature: from 100 to 260 °C
CONSUMPTION
Cooling water: 2 l/min
Sample quantity: from 0,5 to 15 g (generally 2-3 g)
Solvent volume: from 30 to 100 ml
SETTABLE PROGRAMS AND VALUES
Immersion time: from 0 to 999 minutes
Washing time: from 0 to 999 minutes
Recovery time: from 0 to 999 minutes

Accessories

Supplied With:

Extractions cups
SER148/3: SER148/6:
P/Ns:
A00001141
A00000142
Extraction thimbles
33×80 mm
(25pcs/box)
P/N:
CM0111148
Extractions thimbles holders
P/N
A00001142
Inlet tube
P/N
10000280
Heat shield
SER148/3
SER148/6
P/N
40000210 40000220

Optional Accessories

A00001009     –      Printer

A00000011     –      Serial cable

A00001146     –      Thimble weighing cup
A00000061     –       Vaflon seal
A00000142     –        Extraction cup, 6 pcs/box
A00000073     –        IQ/OQ Manual SER148
A00001145     –         Handling device for extraction cups  (SER148/6 only)
A00001147     –         Pincer for weighing cups
A00001149     –         6-position thimbles stand
CM0111148     –         Extraction thimbles 33x80mm, 25pcs/box