Solvent Extractors – SER 148/6 Series 115V/50-60Hz
$12,609.12
Solvent Extractors, 230V/50-60Hz – Series 148 /6
Manufacturer: Velp Scientifica
Part Number: EA-5729-10
- Description
- Size Guide
Description
SOLVENT EXTRACTOR – SER 148 Series
Solvent Extractors – SER 148/6 Series 115V/50-60Hz
Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique.
OVERVIEW
Beats Ordinary Soxhlet Extractor
- Up to 5 times faster than traditional Soxhlet (hot solvent vs. cold solvent)
- Low solvent consumption (high solvent recovery, up to 75%)
- Limited cost per analysis
Convenience & Choice
- Select from 29 on-board empty programs
- Two models available to match sample load
SER 148/3, a 3-position solvent extraction system
SER 148/6, a 6-position solvent extraction system
Operator Safety
- IP 55 protection from particles and liquids
Recommendations
- Combine with HU 6 (Velp Hydrolysis Unit) for high density samples
BENEFITS
Solvent Extractor – Applications and HU6 Hydrolysis Unit
Solvent extraction is used for determination of different substances present in products related to agriculture, industry or in environmental samples.
SER Series can be used, according to official methods, for determining fats, tensides, plasticizers and pesticides on many matrices, including food and feed samples, detergents, rubber and plastic formulates, and many others.
No sample transfer, coming from HU6 Hydrolysis Unit, prevents any possible sample loss, as crucibles can also be used on the two units.
Solvent Extractors – Randall Method, Faster Results
Perform single or multiple solvent extractionswith Randall method, an improvement of Soxhlet technique, as hot solvents are used to speed up the analysis.
In fact, the fast solubilization made by hot solvent permits a considerable reduction of the extraction time (approx. 90 minutes).
The extraction is made by immersion of the sample in the boiling solvent, followed by a rinsing phase with cold solvent.
Maximum reproducibility is ensured, as well as a high recovery rate of the solvent used.
SER Series can be used with a wide range of sample types and with a variety of solvents, forincreased flexibility.
TECHNICAL SPECIFICATIONS
GENERAL FEATURES | |
Construction material: | epoxy painted stainless steel structure |
Number of samples: | SER 148/3 3 positions SER 148/6 6 positions |
2 Displays: | working temperature / settable parameters |
Dimensions (WxHxD): | SER 148/3 480x620x390 mm (18.9×24.4×15.4 in) SER 148/6 700x620x390 mm (27.6×24.4×15.4 in) |
Weight: | SER 148/3 30 Kg (66 lb) SER 148/6 40 Kg (88 lb) |
Power: | SER 148/3 500 W SER 148/6 950 W |
PERFORMANCE | |
Reproducibility (RSD): | ≤ 1% |
Solvent recovery: | from 50 to 75% |
Max volume extraction cup: | 150 ml |
Number of programs: | 29 |
Working temperature: | from 100 to 260 °C |
CONSUMPTION | |
Cooling water: | 2 l/min |
Sample quantity: | from 0,5 to 15 g (generally 2-3 g) |
Solvent volume: | from 30 to 100 ml |
SETTABLE PROGRAMS AND VALUES | |
Immersion time: | from 0 to 999 minutes |
Washing time: | from 0 to 999 minutes |
Recovery time: | from 0 to 999 minutes |
Accessories
Supplied With:
Extractions cups
SER148/3: SER148/6:
P/Ns:
A00001141
A00000142
|
Extraction thimbles
33×80 mm
(25pcs/box)
P/N:
CM0111148
|
Extractions thimbles holders
P/N
A00001142
|
Inlet tube
P/N
10000280
|
Heat shield
SER148/3
SER148/6
P/N
40000210 40000220
|
Optional Accessories
A00001009 – Printer
A00000011 – Serial cable