Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type
$84.43
Universal Input Digital Panel Meter(4-digits red display, AC input) – N24 Z type
Manufacturer: LUMEL
Product Code: N24 Z
- Description
- Size Guide
Description
PRODUCT DESCRIPTION
Thank to competitive price they are ideal solution for low-budget applications.
Features:
- 4-digit LED display, digits of 20 mm high,
- Possible configuration of parameters through the PD14 programmer and the free delivered LPConfig program,
- precision of displayed results (decimal point),
- measurement averaging time,
- recounting of indications (individual characteristic),
- automatic or manual compensation: temperature of cold junction for measurements with thermocouples or wire resistance for Pt100 sensors (N24T),
- Supply: 85…253 V a.c./d.c. or 20…24 V a.c./d.c., 110 V a.c., 230 V a.c.
- Casing protection grade: IP65
- Overall dimensions: 96 x 48 x 64 mm
SPECIFICATIONS
Model |
Measuring ranges |
Parameters |
Overloads |
Errors |
|
N24S |
-11 mV..-10mV..60mV..66mV |
input resistance: >1MΩ |
Short duration overload |
Basic error (at manufacurer’s settings): |
|
-1V..0V..10V..11V |
|||||
-11V..-10V..10V..11V |
|||||
-1mA..0mA..20mA..22mA |
input resistance: 10Ω ±1% |
Short duration overload |
|||
3.6 mA..4mA..20mA..22mA |
|||||
-22mA..-20mA..20mA..22mA |
input resistance: 5Ω ±1% |
||||
N24T |
Pt100 |
-50˚C..150˚C |
current flowing through |
Short duration overload |
Basic error (at manufacturer’s |
-50˚C..400˚C |
|||||
Thermocouple J |
-50˚C..1200˚C |
|
|||
Thermocouple K |
-50˚C..1370˚C |
||||
N24Z |
1..100..120 V a.c. |
input resistance > 2MΩ |
Short duration overload |
Basic error (at manufacturer’s |
|
2,5..250..300 V a.c. |
|||||
4..400..600 V a.c. |
|||||
20..500 Hz |
|||||
0.01..1..1.2 A a.c. |
input resistance: |
Short duration overload |
|||
0,005..5..6 A a.c. |
input resistance: |
||||
N24H |
-1..50..55 V d.c. |
input resistance > 2MΩ |
Short duration overload |
Basic error (at manufacturer’s |
|
-3..200..220 V d.c. |
|||||
-120..-100..100..120 V d.c. |
|||||
-300..-250..250..300 V d.c. |
|||||
-480..-400..400..480 V d.c. |
|||||
-0.1..1..1.1 A d.c. |
input resistance: |
Short duration overload |
|||
-1.2..-1..1..1.2 A d.c. |
|||||
-0.1..5..5.5 A d.c. |
input resistance: |
||||
-6..-5..5..6 A d.c. |
Outputs
Model |
Output |
Voltage |
For N24/ N25 S&T |
Output for supply external transducers |
24V ± 5% 30 mA |
External features
Weight |
<0,25 kg |
|
Dimensions |
96 x 48 x 64 mm |
|
Protection level(acc. to EN 60529) |
ensured by the housing: IP65 |
from the terminal side: IP20 |
Display |
4-digit LED display, 20 mm height, red colour |
indication range: -1999..9999 |
Rated operating conditions
Supply voltage |
230 V ± 10% a.c. (45..65 Hz); 110 V ± 10% a.c. (45..65 Hz) |
input power consumption: 6 VA |
Temperature |
ambient: -10..23..55 ˚C |
storage: -25..85 ˚C |
Relative humidity |
≤ 95% |
condensation inadmissible |
Working position |
any |
|
Preheating time |
30 min |
|
Averaging time |
≥ 0,5 s |
1 second set by default |
Safety and compatibility requirements
Electromagnetic compatibility |
Noise immunity |
acc. to EN 61000-6-2 |
Insulation between circuits |
basic |
ac c. to EN 61010-1 |
Pollution degree |
2 |
|
Installation category |
III (for the 400V option – category II) |
|
Maximal phase-to-earth working |
for the supply circuit: 300V |
|
for the measuring input: 600V – category II (300 V cat. II) |
||
for the programming input: 5V |
||
Altitude above sea level |
<2000 m |
Connection Diagrams
|
|
|
|
|
|
|