Universal Input Digital Panel Meter With Bargraph, NA3 D
$250.62
Universal Input Digital Panel Meter With Bargraph, NA3 D
Manufacturer: LUMEL
Product Code: NA3 D
- Description
- Size Guide
Description
PRODUCT DESCRIPTION
Meters with bargraph are devices ensuring both a high measurement accuracy and very well visualization of the measuring process courses.
Very well visualization of the process is possible through using in meters 3 and 7-coloured bargraph built with diodes made in the gallium nitride technology.
They can find application in various industrial fields, e.g.food industry, pumping stations and savage-treatment plants, chemical industry, weather stations, brewing industry and many other fields where they are destined for visualisation of the measured value and evaluation of the monitored manufacturing process change trend. They can also find application in automation systems where programmable controllers are applied.
Features:
- input: programmable
- voltage: 0…300 mV, 0…200V, – 5…60V,
- current: 0…200 mA, 0…2A,
- thermocouple, resistance thermometers,
- 0…4/10W
- output: programmable – analog, relay (up to 8 relays in meter NA6 type ), digital RS-485 with MODBUS protocol,
- supply: 95…230…253 V a.c./d.c., 20…24…40 V a.c./d.c.
Kinds of execution:
- NA3 type – horizontal, 1-measuring channel in 3 options: with bargraph, with bargraph and display, only with display,
- NA5 type – vertical, 1-measuring channel, with bargraph and display,
- NA6 type – vertical, 2-measuring channels, with 2 bargraphs and 2 displays.
Next to programmable measuring functions meters have many additional functions:
- measurement of the input quantity and displaying it on the LED display and on the bargraph,
- evaluation of the input signal into the indication on the base of the individual linear characteristic,
- arithmetical: raising to a power, extraction of roots(additionally in NA6 type, operations in channels: summation, subtraction, multiplication, division),
- programming of the bargraph colour and resolution,
- signalling of the set alarm value exceeding,
- recording of the measured signal in programmed time intervals,
- memorisation of maximal and minimal values,
- programming of the measurement averaging time,
- programming of the indication resolution,
- lockout of parameter introduction by means of a password,
- servicing of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode,
- galvanic isolation,
- fixing in the panel
External dimensions:
- 96 x 24 x 125mm (NA3 type)
- 48 x 144 x 92mm (NA5 and NA6 type)
SPECIFICATIONS
Inputs |
|
|
Kind of input |
Measuring range |
|
Pt100 |
-200…850°C |
|
Pt500 |
-200…850°C |
|
Pt1000 |
-200…850°C |
|
J (Fe-CuNi) |
-30…1100°C |
|
K (NiCr-NiAl) |
-50…1370°C |
|
N (NiCrSi-NiSi) |
-100…1300°C |
|
E (NiCr-CuNi) |
-20…850°C |
|
R (PtRh13-Pt) |
0…1760°C |
|
S (PtRh10-Pt) |
0…1760°C |
|
T (Cu-CuNi) |
-50…400°C |
|
Resistance |
0…400 Ω, 0…4000 Ω |
|
Voltage |
0…60 mV, Rinp. > 9 MΩ |
|
0…3 V, Rinp. > 4 MΩ |
|
|
0…10 V, Rinp. > 4 MΩ |
|
|
0…200 V, Rinp. > 4 MΩ |
|
|
0…600 V, Rinp. > 4 MΩ |
|
|
Current |
0…5 mA, Rinp. = 4 Ω |
|
0…20 mA, Rinp. = 4 Ω |
|
|
0…2 A, Rinp. = 10 mΩ ± 10% |
|
|
0…5 A, Rinp. = 10 mΩ ± 10% |
|
|
|
|
|
Outputs |
|
|
Kind of output |
Features |
|
Analogue output |
galvanic isolation with resolution 0.025% of range |
|
Relay output |
1 or 2 relays |
|
Open collector |
voltageless of OC type with npn transistor |
|
Digital |
interface type: RS-485 |
|
External Features |
|
||
Readout field |
NA3-F |
4 LED displays with 7 segments, |
|
NA3-B |
multicoloured bargraph as above |
|
|
NA3-D |
4 LED displays with 7 segments, |
|
|
Weight |
< 0.3 kg |
|
|
Overall dimensions |
96 x 24 x 125 mm |
panel cut-out: 92+0,5 x 22.2+0,5 mm |
|
Protec! on grade (acc. to EN 60529) |
IP40 from frontal side |
IP20 from terminal side |
|
|
|
|
|
Rated Operating Conditions |
|
||
Supply voltage |
95…253 V a.c./d.c. |
Power consumption < 8 VA |
|
20…40 V a.c./d.c. |
|||
Temperature |
ambient: -10…23…55°C |
Storage: -25…85°C |
|
Relative humidity |
< 95% |
Condensa! on inadmissible |
|
|
|
|
|
Safety and Compatibility Requirements |
|
||
Electromagnetic compatibility |
Noise immunity |
acc. to EN 61000-6-2 |
|
Noise emissions |
acc. to EN 61000-6-4 |
|
|
Safety requirements |
|
acc. to EN 61010-1 |
|
CONNECTION DIAGRAMS
|
Programmable parameters of the NA3 meter |
|
||
Input |
Input type |
tYP |
|
Mathematical functions |
Func |
|
|
Kind of compensation |
Con |
|
|
Measuring averaging time |
Cnt |
|
|
Displayed characteristic |
Indi |
|
|
Measured value |
I_H1 |
|
|
Displayed value |
d_Y1 |
|
|
Measured value |
I_H2 |
|
|
Displayed value |
d_Y2 |
|
|
Bargraph |
Bargraph type |
tYPb |
|
Bargraph colour |
coLr |
|
|
Lower bargraph threshold |
brL |
|
|
Upper bargraph threshold |
brH |
|
|
Alarm 1 |
Lower alarm threshold |
PrL |
|
Upper alarm threshold |
PrH |
|
|
Alarm type |
tYPA |
|
|
Delay of alarm operation |
dLY |
|
|
Support of alarm signalling |
HOLd |
|
|
Colour of the lower threshold alarm index |
CurL |
|
|
Colour of the upper threshold alarm index |
CurH |
|
|
Alarm 2 |
Lower alarm threshold |
PrL |
|
Upper alarm threshold |
PrH |
|
|
Alarm type |
tYPA |
|
|
Delay of alarm operation |
dLY |
|
|
Support of alarm signalling |
HOLd |
|
|
Colour of the lower threshold alarm index |
CurL |
|
|
Colour of the upper threshold alarm index |
CurH |
|
|
Alarm 3 |
Lower alarm threshold |
PrL |
|
Upper alarm threshold |
PrH |
|
|
Alarm type |
tYPA |
|
|
Delay of alarm operation |
dLY |
|
|
Support of alarm signalling |
HOLd |
|
|
Colour of the lower threshold alarm index |
CurL |
|
|
Colour of the upper threshold alarm index |
CurH |
|
|
Output |
Output characteristic |
IndO |
|
Displayed value |
d_H1 |
|
|
Value on the analog output |
O_Y1 |
|
|
Displayed value |
d_H2 |
|
|
Value on the analog output |
O_Y2 |
|
|
RS-485 baud rate |
bAud |
|
|
Kind of RS-485 transmission |
trYb |
|
|
Device address |
Adr |
|