OVERVIEW

Max capacity [Max]: 1500kg

Readability [d]: 500g

Ramp scales with stainless steel load cells is widely applied in meat, fish, pharmaceutical, cosmetic and chemical industry.
The WPT/4N series is manufactured in complete stainless steel technology with stainless steel indicator PUE C/31H series installed on a long cable.

Ramp scales is manufactured from OH18N9 stainless steel with IP 68. On special order, it is possible to manufacture ramp scales in upgraded anti-corrosion stainless steel version.

Scales is available in dual range version on surcharge.

FUNCTIONS


PERCENT WEIGHING

Percent Weighing function is used for comparision of measured products with mass standard. Mass of a mass standard may be a numeric value taken from a database or it may be determined through a measurement process. Each measured product is compared to mass standard, mass of which is presumed as a model 100% ideal mass. For products weighing less than the mass standard, obtained results are lower than 100%, for products weighing more, the obtained results are greatly  exceeded.

TOTALIZING

Function adding new mass value to already obtained one. This allows to determine mass content of the mixture, being a composition of number of different consistence components. Totalizing is limited by maximum capacity parameter.

PEAK HOLD

Function registering the greatest temporary indication occurring in course of the weighing process. It is most often used in medical scales in order to hold the measurement indication.

NEWTON UNIT MEASUREMENT

Function allowing to perform the measurement in Newton unit, it may be used for processes aiming to determine force resulting in the sample damage.

ANIMAL WEIGHING

Process of mass determination for a product which may unwillingly reposition within the weighing pan. Mass determination in such cases requires much longer period of time when compared to typical weighing process. It is the user who defines period of time needed for control of measured product mass. The user can thus optimaze the function depending on the measured product characteristics.

PARTS COUNTING

Function using mass measurement for determination of  measured items quantity. Mass of a single item is required for this process. It may be either estimated through weighment or taken from a database. For items counting the following algorithm is used: all items mass / single item mass = quantity. Function operation is supported by a mechanism of Automatic Correction of Accuracy. This allows updating single item mass in course of the process. To a certain extend Automatic Correction of Accuracy eliminates error which may be a result of different mass values of seemingly alike single elements. For industry solutions items counting may be simultaneously carried out with check weighing and dosing thus industry solutions feature audio signaling base informing that specified number of items has been weighed. It is possible to apply weighing systems using few platforms of different MAX capacities and different accuracies.

 

Datasheet

Maximum capacity [Max] 1500 kg
Readability [d] 500 g
Tare range -1500 kg
Display LCD (backlit)
IP rating IP 68 construction, IP 68 (1h max)/69 indicator
Power supply 100 ÷ 240 V AC 50 ÷ 60 Hz / 12 V DC and battery
Operating temperature -10 ÷ +40 °C
Atmospheric humidity 10÷85% RH no condensation
Weighing pan dimensions 1500×1500 mm
Device dimensions 2450×1820×77 mm
Communication interface RS 232
Scale mass with indicator 270 kg