Metash – UV-9000S Double Beam UV VIS Spectrophotometer

$8,577.70

UV-9000 series are widescreen double beam spectrophotometer. They adopt a double beam long light path design to ensure stability and accuracy. They are the best choice of high-quality spectrophotometers.

Description

Metash - Model UV-9000S - Double Beam UV Vis Spectrophotometer

Metash – Model UV-9000S  Double Beam UV Vis Spectrophotometer

Manufacturer: METASH

 

UV-9000 series are widescreen double beam spectrophotometer. They adopt a double beam long light path design to ensure stability and accuracy. They are the best choice of high-quality spectrophotometers.

Key Features

Lightpath design: double beam

UV-9000 series’ double light path design can prevent circuit fluctuation and stray light to ensure the stability of the instrument.

Powerful software functions

Multi-functions like spectrum scanning, standard curve, kinetics, multi-wavelength scanning, DNA/Protein testing can be operated directly on the PC.

Long path light design

UV-9000 series’ unique 520mm long light path design greatly improved resolution and the bandwidth can reach 0.5nm.

Multi-functions on Spectrophotometer

Multi-functions operated directly on the spectrophotometer and display the test results’ curve and data: wavelength scanning, standard curve, kinetics, multi-wavelength scanning, DNA/Protein test.

16mm optical base

UV-9000 series use a rigid 16mm die-cast aluminium base as their optical mount to ensure stability and reliability.

Perfect calibration system

All baselines, wavelength, dark current can be calibrated automatically to keep good running conditions.

6 inches LCD display

UV-9000 series has a 6 inches LCD display to show results and curves directly on the screen.

Data output

UV-9000 series are equipped with a USB port to connect with a PC, the software comes standard with the instrument.

Technical Specifications

Model: UV-9000S

Optical System: Double Beam (1200 Lines/mm Grating)

Wavelength Range: 190-1100nm

Bandwidth: 0.5, 1, 2, 4nm

Wavelength Accuracy: ±0.1nm (D2 656.1nm), ±0.3nm @all

Wavelength Repeatability: 0.2nm

Photometric Accuracy: ±0.2%T(0-100%T)

Photometric Repeatability: ≤0.1%T(0-100%T)

Photometric Range: -0.3-3A, 0-200%T, 0-9999C

Stability: ± 0.001A/h @ 500nm

Baseline Flatness: ± 0.001A/h

Noise: ± 0.0005A/h

Stray Light: ≤0.03%T @ 220nm, 360nm

Data Output Port: USB

Printer Port: Parallel Port

Display: 320*240 Dots LCD

Lamps: Tungsten Lamp & Deuterium Lamp

Detector: Silicon Photodiode

Power Requirements: AC 220V/50Hz or AC 110V/60Hz

Dimension: 625*430*206mm

Weight: 30kg

Vendor Information

  • Address: