CompactDry™ LM (Listeria Monocytogenes)
$135.48 – $3,264.74
CompactDry™ LM (Listeria Monocytogenes)
Cat No:
Manufacturer: NISSUI Pharmaceutical Co., Ltd.
- Description
- Size Guide
- Additional information
- SPECIFICATIONS
- DATASHEETS
Description
CompactDry™ LM
CompactDry™ LM (Listeria Monocytogenes)
CompactDry® is a ready-to-use test method for microbiological testing in food and water laboratories which helps to reduce the labour hours needed to perform microbial testing. Maximising productivity by increasing efficiency.
CompactDry™ is a ready-to-use test method which helps to reduce the time needed to perform microbial testing. Therefore, it allows maximum productivity by increasing efficiency. The plates can be used to test raw materials as well as finished products like food, beverage, meat, cosmetic or other samples. The Compact Dry plates can also be used as a contact plate for difficult areas using the Compact Dry swab.
CompactDry LM ready-to-use, chromogenic plate for enumeration and detection of Listeria monocytogenes
Operating Procedure for Detection
[u]Preparation of specimen [/u]
1) Detection in solid foodstuffs, water or liquid foodstuffs
Add 9 times volume of half-Fraser broth to the sample and homogenize by Homogenizer. Incubate at 30 + 1°C for 25 + 1 hours for enrichment culture.
2) Detection in wiped sample
Add 9 times volume of half-Fraser broth to the wiping solution. Incubate at 30 + 1°C for 25 + 1 hours for enrichment culture.
Direction/b]
1) Open aluminum pouch and take out a set of 4 plates.
2) Detach the quantity you need from a set of four by bending up and down while pressing the lid.
3) Take off the lid of the plate and drop 1 ml of a sterilized diluent (ex. saline) in the middle of a dry sheet to transform the whole of the sheet to gel.
4) Drop 0.1 mL of enrichment culture in the middle of the sheet. Streak the sheet with the inoculum from top to bottom by a loop softly and spread it over the whole of the sheet in order to get single colonies.
5) Turn over the capped plate after putting the lid again, and then incubate for 24 + 2 hours at 37 + 1°C. If colonies of presumptive L. monocytogenes are evident, the incubation may be stopped at this stage. If they are not evident, incubate for additional 24 + 2 hours at 37 + 1°C.
Operating Procedure for Enumeration
Preparation of specimen
1) Viable count in solid foodstuffs
Add 9 times volume of Buffered Peptone Water) to the sample and homogenize by Homogenizer. Pipette 1mL of homogenized specimen (to be further diluted if necessary) in the middle of a dry sheet of Compact Dry LM.
2) Viable count in water or liquid foodstuffs
Pipette 1mL of liquid sample (to be diluted if necessary) in the middle of a dry sheet of Compact Dry LM.
3) Viable count in wiped sample
Inoculate 1mL of wiping solution (to be diluted if necessary) in the middle of a dry sheet of Compact Dry LM. It is recommended to use Compact Dy swab
Direction
1) Open aluminum pouch and take out a set of 4 plates.
2) Detach the quantity you need from a set of four by bending up and down while pressing the lid. Use a set of four plates being connected when a series of diluted samples is inoculated.
3) Take off the lid of the plate and drop 1 ml of specimen in the middle of a dry sheet. Specimen diffuses automatically and evenly into all over the sheet (a medium size of 20 cm2) to transform it into gel.
4) Turn over the capped plate after putting the lid again, and then incubate for 24 + 2 hours at 37 + 1°C. If colonies of presumptive L. monocytogenes are evident, the incubation may be stopped at this stage. If they are not evident, incubate for additional 24 + 2 hours at 37 + 1°C
Precaution for use:
Precaution for Detection and Enumeration
1) During inoculation, do not touch the surface of medium and/or tip of dropper, and be careful to avoid any contamination by falling microorganism.
2) During incubation, keep lid tight of Compact Dry to avoid any possible dehydration.
3 )It is recommended to use a stomacher bag with filter to eliminate risks of carry-over of tiny pieces of foodstuffs into the surface of the medium.
Precaution for Detection
4) During streaking, do not put strength into a loop and slip it softly on the surface of a sheet. A loop which has a large diameter and a smooth surface is suitable for streaking.
Precaution for Enumeration
5) Specimen should be diluted by buffer solution to the level of concentration of less than 300 cfu/plate.
6) If bacteria of more than 10 to 4 cfu are inoculated in a plate, no independent colonies are formed, and the whole medium gets stained.
7) If the nature of specimen does affect the result, the specimen should be inoculated only after the cause is eliminated by means of such as dilution and others. For example: specimens such as high viscosity, deep color, and too high or too low pH.
Interpretation in Detection
1) Interpret red colonies with or without blue surrounds as presumptive positive for Listeria monocytogenes.
2) If a volume of L. monocytogenes is too much, no single colonies are formed and the whole of a sheet or the streaked part of a sheet looks red-colored. Interpret the result as presumptive positive in this case too.
Interpretation in Enumeration
3) Count red colonies with or without blue surrounds for presumptive L. monocytogenes.
Interpretation in Detection and Enumeration
4) If presumptive colonies of L. monocytogenes are observed, perform confirmation tests by ISO11290-1:2017, ISO11290-2:2017 or other methods.
Precaution for interpretation
1)Listeria ivanovii also forms red colonies with or without blue surrounds like L. monocytogenes.
2) Listeria spp. except for L. monocytogenes and L. ivanovii form blue/green colonies. Bacteria other than Listeria spp. are inhibited by selective agents in the medium, or do not form colored colonies even if they grow. Rarely some of Bacillus spp. may form relatively large, flat and orange colonies.
3) L. monocytogenes may form orange, reddish-brown or reddish-purple colonies in addition to red colonies.
4) White paper placed under the plate can make it easy to observe colonies.
5) The plate size of LM plate is 20 cm2, and the back of container has a carved grid of 1cm x 1cm to make colony counting easier. When it is difficult to count the colonies due to a great large number of colonies grown in the medium, the total bacterial number can be obtained by multiplying 20 by an average number of colonies per grid (1cm x 1cm) calculated from representative grids.
International Certifications
To ensure reliability, Nissui Pharmaceutical has gained certifications from the AOAC in the U.S. and MicroVal and NordVal in the EU. In Japan, our analytical approaches have been included in the Standard Methods of Analysis in Food Safety Regulation.
Membrane filter method: procedure for CompactDry™
Additionally membrane filters can be tested using CompactDry™ plates. Filter 1ml water or any other liquid using an ordinary membrane filter (e.g. 47 mm, 45 µm), then pipette 1 ml of sterile water into the middle of the Compact Dry plate and place the filter on the CompactDry™ plate. The filter should be trap side up. Colonies will grow on the filter.
Additional information
PACKAGING TYPE | 40 Plates, 240 Plates, 500 Plates, 1404 Plates |
---|
CompactDry™ LM
Features and Benefits include:
- Ready to use
- No spreading
- Long shelf life at room temperature
- Easily stackable in incubator
- Easy identification of presumptive colonies on chromogenic media
- Wide choice of plates available including Total Counts, E. coli, Listeria sp., Salmonella sp., Vibrio parahaemolyticus, Enterococcus, Enterobacteriaceae, Yeast and Molds.
Membrane filter method: procedure for CompactDry™
Additionally membrane filters can be tested using CompactDry™ plates. Filter 1ml water or any other liquid using an ordinary membrane filter (e.g. 47 mm, 45 µm), then pipette 1 ml of sterile water into the middle of the Compact Dry plate and place the filter on the CompactDry™ plate. The filter should be trap side up. Colonies will grow on the filter.
How to use Membrane Filter method on Compact Dry Plates
PRODUCT:
Package Size | Quantity | |||
---|---|---|---|---|
![]() |
||||
40 plates | 40 Plates/Box | |||
240 plates | 240 Plates/Box | |||
500 plates | 500 Plates/Box | |||
1404 Plates | 1404 Plates/Box | |||
![]() |
CompactDry™ – MANUALS