CONDUCTIVITY PANELS – PNL S507-CMK
MANUFACTURER: STEIEL ELETTRONICA Srl
CAT NO: PNL S507-CMK
- Description
- Size Guide
- SPECIFICATONS
- DOWNLOADS
- Vendor Info
- More Products
Description
CONDUCTIVITY PANELS – PNL S507-CMK
PP panel (495×660 mm), S507-IN unit, SF78M/CMK probe-holder, CMK50 cell, CT-01S signal converter (range to be specified upon order)
DESCRIPTION OF CONDUCTIVITY PANELS – PNL S507-CMK
STEIEL offers a wide range of “turnkey” solutions, including instrument and measurement sensors assembled on panel.
The more complex systems are also equipped with an adjustment dosing pump and / or data recording / managing device.
These models have been designed for conductivity measurements in aqueous solutions on medium-high range, with CMK50 inductive cell, to be combined with a specific signal converter.
TECHNICAL FEATURES OF CONDUCTIVITY PANELS – PNL S507-CMK
- Panel with four holes for wall mounting
- Panel dimensions:
- 500 x 600 mm, without dosing pump
- 595 x 750 mm, with dosing pump
- Customizable graphic layout on request
- The basic system includes:
- S507-IN instrument with 4-20 mA input
- CMK50 cell for inductive measurement of conductivity
- Signal converter, with measure range to be specified upon order
- Flow-through probe holder with cup or model for immersion installation
- Upon request, the RW14 supervisor is available, for remote managing through RS232 serial line
TECHNICAL DATA OF CONDUCTIVITY PANELS – PNL S507-CMK
- Power Supply: 230 V~ ±10%, 50/60Hz, max. 7 VA (other options on request)
- Display: dual row, alphanumeric LCD, with backlight
- Analogic Inputs: precision better than 0.3% FS / repeatability better than 0.2% FS
- Conductivity Input: 4-20 mA input for CMK inductive cell, combined with a signal transmitter, available on removable 4-pole terminal block
- Temperature Input: directly from Pt100 sensor, available on removable 2-pole terminal block; range -50.0 … +200.0 °C
- Digital Input: OFF input for disabling outputs; accept voltage-free contact; 5V power output, max 5mA
- Relay Outputs: 2 independent outputs, available on removable 5-pole terminal block; contact max load 250 V~ , 3 A resistive
- Current Output: 0 / 4-20 mA (configurable); max load 600Ω ; error max 0.5% FS; with galvanic separation
- Serial Port: standard RS232, on removable 4-pole terminal block
- Environment: Storage temperature -20 … +60 °C; Working temperature -10 … +50 °C; RH max 90% no condensing
- Casing: ABS, watertight, wall-mounting with 4 screws
- Protection Rate: IP66
- Power Supply: 230 V~ ±10%, 50/60Hz, max. 7 VA (other options on request)
- Display: dual row, alphanumeric LCD, with backlight
- Analogic Inputs: precision better than 0.3% FS / repeatability better than 0.2% FS
- Conductivity Input: 4-20 mA input for CMK inductive cell, combined with a signal transmitter, available on removable 4-pole terminal block
- Temperature Input: directly from Pt100 sensor, available on removable 2-pole terminal block; range -50.0 … +200.0 °C
- Digital Input: OFF input for disabling outputs; accept voltage-free contact; 5V power output, max 5mA
- Relay Outputs: 2 independent outputs, available on removable 5-pole terminal block; contact max load 250 V~ , 3 A resistive
- Current Output: 0 / 4-20 mA (configurable); max load 600Ω ; error max 0.5% FS; with galvanic separation
- Serial Port: standard RS232, on removable 4-pole terminal block
- Environment: Storage temperature -20 … +60 °C; Working temperature -10 … +50 °C; RH max 90% no condensing
- Casing: ABS, watertight, wall-mounting with 4 screws
- Protection Rate: IP66