Digital Display Panel (1 row, 230mm digit, 4 red digits) DNL2

$927.84

Digital Display Panel (1 row, 230mm digit, 4 red digits) DNL2

Manufacturer: LUMEL

Product Code: DNL2

SKU: AMI-51628-66

Description

Digital Display Panel (1 row, 230mm digit, 4 red digits) DNL2

Digital Display Panel (1 row, 230mm digit, 4 red digits) DNL2

Description of Digital Display Panel (1 row, 230mm digit, 4 red digits) DNL2

DNL2 and DNL3 displays are designed to visualize data of the processes through RS485 or analog input.

DNL characteristics:

  • number of rows 1 or 2 (for 2 rows – visualization of data from 2 different devices),
  • digit height 230 or 305 mm,
  • visibility up to 120m,
  • display colour: yellow or red,
  • brightness sensor installed (brightness changes depending on outside  conditions),
  • concetration of data from up to 10 devices (10 registers),
  • Modbus RTU Slave and Modbus RTU Master funcionality,
  • analog input 4…20 mA (option),
  • built-in power supplyer (15V d.c./50mA) for external transducers (option).

SPECIFICATIONS

External Features

 

Readout field

1 row x 4 digits
or 2 rows x 4 digits

DNL2 – digit height 230 mm
DNL3 – digit height 305 mm

 

Overall dimensions

acc. to the table 1 and fig. 1

 

 

Weight DNL2

one row : 5,4 kg

two rows: 10,8 kg

 

Weight DNL3

one row: 7,6 kg

two rows: 15,2 kg

 

Protec! on grade

for housing: IP40

for terminals: IP10

 

 

 

 

 

Digital Interface

 

Interface type

Mode

Baud rate

 

RS-485 Modbus RTU Slave

8N1, 8N2, 8E1, 8O1

2.4, 4.8, 9.6, 14.4, 19.2, 28.8,
38.4, 57.6, 76.8, 115.2. kbit/s

 

RS485 Modbus RTU Master

8N1, 8N2, 8E1, 8O1

2.4, 4.8, 9.6, 14.4, 19.2, 28.8,
38.4, 57.6, 76.8, 115.2 kbit/s

 

 

 

 

 

Inputs

 

Input type

Range

Error

 

RS485 Modbus RTU Master

 

 

 

current

4…20 mA d.c.

– basic error: 0.1%
– additional error from temperature
changes: 0.05 %/10 °C

 

 

 

 

 

Outputs

 

Output type

Properties

 

supplying output for transducers

15V d.c. / 50mA

 

 

 

 

Rated Operating Conditions

 

Supply voltage

100…240 V a.c.

50..60 Hz

 

Power consumption

< 55 VA

 

 

Temperature

ambient: -10…23…50°C

storage: -25…75°C

 

Relative humidity

25 .. 95%

inadmissible condensa! on

 

Operating position

any

 

 

External magnetic field

0…40…400 A/m

 

 

 

 

 

 

Safety and Compatibility Requirements

 

Electromagnetic compatibility

Noise immunity

wg PN-EN 61000-6-2

 

Noise emissions

wg PN-EN 61000-6-4

 

Isolation between circuits

bsic

wg PN-EN 61010-1

 

Pollution level

2

 

Installation category

III

 

Maximum phase-to-earth operating voltage

– for supply and measuring circuits 300V
– for other circuits 50 V

 

Altitude above seal level

<2000 m

 

 

Vendor Information