Short circuit loop impedance meter MZC-330S
$3,523.97
Short Circuit Loop Impedance meter
MODEL: MZC-330S
MANUFACTURER: SONEL
WEIGHT: 6.6KG
Short circuit loop impedance meter MZC-330S features:
- measurements in installations with rated voltages between: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V and frequencies 45…65 Hz,
- ability to perform measurements in short circuit system: phase-phase, phase-protective, phase-neutral,
- differentiation between the phase voltage and the inter-phase voltage while calculating the short circuit current,
- ability to change the length of test lead,
- four-pole method, test leads do not require calibration (measurement with current 300 A).
- Touch voltage and touch shock voltage measurement with resistor 1 kΩ).
- AC voltage measurement in range 0…750V.
- Memory of 999 measurement results with an ability to transfer the data to a PC
- Ability to transmit date thru USB and Bluetooth.
- Meter meets the requirements of the standard EN 61557.
- Description
- Size Guide
- TECHNICAL INFORMATION FOR SHORT CIRCUIT LOOP IMPEDANCE METER MZC-330S
- Vendor Info
- More Products
Description
Short circuit Loop Impedance meter MZC-330S
The Short circuit Loop Impedance meter has been designed for fitters and measurement technicians performing services in residential buildings, office blocks, manufacturing plants and any facilities possessing a low-voltage electrical system. The Short circuit Loop Impedance meter is also recommended for electrical maintenance personnel as this loop impedance meters are used to ensure that protective devices (fuses, circuit breakers etc) operate effectively making no room for harm situations.
Measurement of very low short circuit loop impedances (with resolution 0,1 mΩ) with a current of 130 A at 230 V; maximum 300 A at 750 V or with a current 24 A at 230 V, maximum 30 A at 750 V (with resolution 0,01 Ω)
- measurements in installations with rated voltages between: 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V and frequencies 45…65 Hz,
- ability to perform measurements in short circuit system: phase-phase, phase-protective, phase-neutral,
- differentiation between the phase voltage and the inter-phase voltage while calculating the short circuit current,
- ability to change the length of test lead,
- four-pole method, test leads do not require calibration (measurement with current 300 A).
- Touch voltage and touch shock voltage measurement with resistor 1 kΩ).
- AC voltage measurement in range 0…750V.
- Memory of 999 measurement results with an ability to transfer the data to a PC
- Ability to transmit date thru USB and Bluetooth.
- Meter meets the requirements of the standard EN 61557.
Voltage measurements (True RMS)
| Range | Resolution | Accuracy |
|---|---|---|
| 0…750 V | 1 V | ±(2% m.v. + 2 digits) |
- frequency range: DC, 45…65 Hz
- input impedance of the voltmeter: >200 kΩ
Frequency measurements (for voltages in range 95…750 V)
| Range | Resolution | Accuracy |
|---|---|---|
| 45,0…65,0 Hz | 0,1 Hz | ±(0,1% m.v. + 1 digit) |
Short circuit loop parameters measurement using high current (4p, Imax=300 A)
High-current of measurement of short circuit loop impedance ZS:
measuring range according to IEC61557: 7,2 mΩ…1999 mΩ
| Range | Resolution | Accuracy |
|---|---|---|
| 0…199,9 mΩ | 0,1 mΩ | ±(2% m.v. + 2 mΩ) |
| 200…1999 mΩ | 1 mΩ | ±(2% m.v. + 2 mΩ) |
Short circuit resistance R and reactance XS display range
| Range | Resolution | Accuracy |
|---|---|---|
| 0…199,9 mΩ | 0,1 mΩ | ±(2% m.v. + 2 mΩ) impedance reading for a particular measurement |
| 200…1999 mΩ | 1 mΩ | ±(2% m.v. + 2 mΩ) impedance reading for a particular measurement |
Short circuit current indication
measuring range according to IEC 61557:
- for Un = 230 V 115,0 A…32,0 kA
- for Un = 400 V 200 A…55,7 kA
- for Un = 500 V 250 A…69,4 kA
- for Un = 690 V 345 A…95,8 kA
| Range | Resolution | Accuracy |
|---|---|---|
| 115,0…199,9 A | 0,1 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 200…1999 A | 1 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 2,00…19,99 kA | 0,01 kA | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 20,0…199,9 kA | 0,1 kA | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 200 kA…* | 1 kA | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
* 230 kA for UL-N
400 kA for UL-L
Short circuit loop parameters measurement using standards current (2p, Imax=30 A)
Touch voltage measurements UST and shock voltage UT
| Range | Resolution | Accuracy |
|---|---|---|
| 0…100 V | 1 V | ±(10% m.v. + 2 digits) |
Short circuit loop impedance ZS measurement:
measuring range according to IEC61557: 0,13 Ω…199,9 Ω for test leads length 1,2 m
| Range | Resolution | Accuracy |
|---|---|---|
| 0,00…19,99 Ω | 0,01 Ω | ±(2% m.v. + 3 digits) |
| 20,0…199,9 Ω | 0,1 Ω | ±(3% m.v. + 3 digits) |
Short circuit resistance RS and reactance XS display range
| Range | Resolution | Accuracy |
|---|---|---|
| 0,00…19,99 Ω | 0,01 Ω | ±(2% m.v. + 3digits) impedance reading for a particular measurement |
| 20,0…199,9 Ω | 0,1 Ω | ±(3% m.v. + 3 digits) impedance reading for a particular measurement |
Readings short circuit current
| Range | Resolution | Accuracy |
|---|---|---|
| 1,150…1,999 A | 0,001 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 2,00…19,99 A | 0,01 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 20,0…199,9 A | 0,1 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 200…1999 A | 1 A | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 2,00…19,99 kA | 0,01 kA | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
| 20,0…40,0 kA | 0,1 kA | Accuracy of the current indication computed, respectively, with the use of resistance measurements |
„m.v.” – measured value.
Electric security for Short Circuit Loop Impedance meter MZC-330S:
- type of insulation: double, according to PN-EN 61010-1 and IEC 61557;
- measurement category: IV 600 V acc. to PN-EN 61010-1;
- protection class acc. PN-EN 60529: IP20 (IP67 with front cover closed);
Other technical data for Short Circuit Loop Impedance meter MZC-330S:
- power supply: build in Li-Ion 7,2 V/8,8 Ah
- resistor limited the current:
- for 4 pole method 4p: 1,8 Ω;
- for two pole method 2p: 9,4 Ω for U≤253 V, 19 Ω for U>253 V,
- number of short circuit loop measurements: 2000 (4/min.),
- temperature coefficient: ±0,1% measured value /°C;
- dimensions: 390 mm x 310 mm x 170 mm;
- weight: 6,6 kg
Rated operational conditions for Short Circuit Loop Impedance meter MZC-330S:
- operating temperature 0…+40 °C
Vendor Information
-
-
Instrumentation Products, Level Instruments, Level Sensors, Level Switch, Pressure Sensors
Levelpro TVU Multi-Color Level Display, 4-20 mA
Price range: $1,869.86 through $2,245.76Select options This product has multiple variants. The options may be chosen on the product pageQuick View -
Instrumentation Products, Data logger accessory, Environmental Quality & Occupational health Monitoring, Environmental Quality & Occupational health Monitoring, Humidity & Temperature, Humidity Dataloggers, Instrumentation Products
PMSA At-line moisture analyser for determination of water content of single paper sheets
$12,145.28 -
Instrumentation Valves, Fittings, Tubes, Hoses & Connectors, Relief Valves
Truflo BRP Back Pressure Relief Valve – PVC ½”-2″
Price range: $435.56 through $1,015.86Select options This product has multiple variants. The options may be chosen on the product pageQuick View