Universal Input Digital Bargraph Panel Meter, NA6
$385.44
Universal Input Digital Bargraph Panel Meter, NA6
Manufacturer: LUMEL
Product Code: NA6
- Description
- Size Guide
Description
PRODUCT DESCRIPTION
Meters with bargraph are devices ensuring both a high measurement accuracy and very well visualization of the measuring process courses.
Very well visualization of the process is possible through using in meters 3 and 7-coloured bargraph built with diodes made in the gallium nitride technology.
They can find application in various industrial fields, e.g.food industry, pumping stations and savage-treatment plants, chemical industry, weather stations, brewing industry and many other fields where they are destined for visualisation of the measured value and evaluation of the monitored manufacturing process change trend. They can also find application in automation systems where programmable controllers are applied.
Features:
- input: programmable
- voltage: 0…300 mV, 0…200V, – 5…60V,
- current: 0…200 mA, 0…2A,
- thermocouple, resistance thermometers,
- 0…4/10W
- output: programmable – analog, relay (up to 8 relays in meter NA6 type ), digital RS-485 with MODBUS protocol,
- supply: 95…230…253 V a.c./d.c., 20…24…40 V a.c./d.c.
Kinds of execution:
- NA3 type – horizontal, 1-measuring channel in 3 options: with bargraph, with bargraph and display, only with display,
- NA5 type – vertical, 1-measuring channel, with bargraph and display,
- NA6 type – vertical, 2-measuring channels, with 2 bargraphs and 2 displays.
Next to programmable measuring functions meters have many additional functions:
- measurement of the input quantity and displaying it on the LED display and on the bargraph,
- evaluation of the input signal into the indication on the base of the individual linear characteristic,
- arithmetical: raising to a power, extraction of roots(additionally in NA6 type, operations in channels: summation, subtraction, multiplication, division),
- programming of the bargraph colour and resolution,
- signalling of the set alarm value exceeding,
- recording of the measured signal in programmed time intervals,
- memorisation of maximal and minimal values,
- programming of the measurement averaging time,
- programming of the indication resolution,
- lockout of parameter introduction by means of a password,
- servicing of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode,
- galvanic isolation,
- fixing in the panel
External dimensions:
- 96 x 24 x 125mm (NA3 type)
- 48 x 144 x 92mm (NA5 and NA6 type)
SPECIFICATIONS
NPUTS:
Pt100 |
(-200…+850)°C measuring sub-range: 320°C |
Pt500 |
(-200…+850)°C measuring sub-range: 230°C |
Pt1000 |
(-200…+850)°C measuring sub-range: 290°C |
J (Fe-CuNi) |
(-100…+1100)°C measuring sub-ranges: 350°C, 700°C |
K (NiCr-NiAl) |
(-100…+1370)°C measuring sub-ranges: 450°C, 950°C |
N (NiCrSi-NiSi) |
(-100…+1300)°C measuring sub-ranges: 550°C,1000°C |
E (NiCr-CuNi) |
(-100…+850)°C measuring sub-ranges: 250°C, 520°C |
R (PtRh13-Pt) |
(0…+1760)°C |
S (PtRh10-Pt) |
(0…+1760)°C |
T (Cu-CuNi) |
(-50…+400)°C |
Resistance measurement: |
0… 10kΩ measuring sub-ranges: |
Voltage measurement: |
± 300 mV input resistance > 9 MΩ |
Current measurement: |
± 40 mA: input resistance < 4 Ω |
Intensity of the current flowing |
< 400 µA |
Resistance of wires linking the |
< 20 Ω/wire |
Thermocouple characteristics, acc. EN 60584-1 |
OUTPUTS
Analogue outputs: |
– galvanically isolated, with a resolution 0.025% of the range. |
Relay outputs: 4 relays |
– voltageless make contacts – maximal load: |
8 outputs of OC type (open |
voltageless, of OC type with npn transistor (maximal load 25 mA) range of |
Digital outputs: |
– interface: RS-485, |
Memory parameters: |
– meter memory ( recording): |
Basic error: |
– NA5, NA6 |
Additional error from ambient |
– NA5, NA6 |
Averaging time: |
min 200 |
Rated operation conditions: |
– supply voltage depending on the version code: |
Sustained overload: |
– thermocouples, resistance thermometers: 1% |
Short duration overload (3 s): |
– inputs of sensors: 30 V |
Bargraph resolution: |
programmable |
Bargraph accuracy: |
± 0.5 segment |
Servicing: |
|
Protection grade ensured: |
– by the housing: |
Dimensions: |
NA5, NA6: 48 x 144 x 100 mm (with terminals) |
Cut-out dimensions in the panel: |
NA5, NA6: 44+0.5 x 137.5+0.5 mm |
Weight: |
< 0.4 kg |
Power consumption: |
< 12 VA |
Resistance against voltage decay: |
according EN 61000-6-2 |
Electromagnetic compatibility: |
– immunity: EN 61000-6-2 |
Safety requirements according |
– installation category: III |
Display Field: NA5: 4 seven- |
digit height: 7 mm |
NA6: 2 x 4 seven-segment |
digit height: 7 mm |