Universal Input Digital Bargraph Panel Meter, NA6

$385.44

Universal Input Digital Bargraph Panel Meter, NA6

Manufacturer: LUMEL

Product Code: NA6

SKU: AMI-51628-53

Description

PRODUCT DESCRIPTION

Universal Input Digital Bargraph Panel Meter, NA6

Programmable meters with multicolour bargraph indicators NA3, NA5 and NA6 type are destined to measure and recording d.c. current or d.c. voltage, temperature, resistance and other non-electrical magnitudes like: level, flow, pressure, humidity

Meters with bargraph are devices ensuring both a high measurement accuracy and very well visualization of the measuring process courses.
Very well visualization of the process is possible through using in meters 3 and 7-coloured bargraph built with diodes made in the gallium nitride technology.
They can find application in various industrial fields, e.g.food industry, pumping stations and savage-treatment plants, chemical industry, weather stations, brewing industry and many other fields where they are destined for visualisation of the measured value and evaluation of the monitored manufacturing process change trend. They can also find application in automation systems where programmable controllers are applied.
Features:

  • input: programmable
    • voltage: 0…300 mV, 0…200V, – 5…60V,
    • current: 0…200 mA, 0…2A,
    • thermocouple, resistance thermometers,
    • 0…4/10W
  • output: programmable – analog, relay (up to 8 relays in meter NA6 type ), digital RS-485 with MODBUS protocol,
  • supply: 95…230…253 V a.c./d.c., 20…24…40 V a.c./d.c.

Kinds of execution:

  • NA3 type – horizontal, 1-measuring channel in 3 options: with bargraph, with bargraph and display, only with display,
  • NA5 type – vertical, 1-measuring channel, with bargraph and display,
  • NA6 type – vertical, 2-measuring channels, with 2 bargraphs and 2 displays.

Next to programmable measuring functions meters have many additional functions:

  • measurement of the input quantity and displaying it on the LED display and on the bargraph,
  • evaluation of the input signal into the indication on the base of the individual linear characteristic,
  • arithmetical: raising to a power, extraction of roots(additionally in NA6 type, operations in channels: summation, subtraction, multiplication, division),
  • programming of the bargraph colour and resolution,
  • signalling of the set alarm value exceeding,
  • recording of the measured signal in programmed time intervals,
  • memorisation of maximal and minimal values,
  • programming of the measurement averaging time,
  • programming of the indication resolution,
  • lockout of parameter introduction by means of a password,
  • servicing of the RS-485 interface in MODBUS protocol, both in ASCII and RTU mode,
  • galvanic isolation,
  • fixing in the panel

External dimensions:

  • 96 x 24 x 125mm (NA3 type)
  • 48 x 144 x 92mm (NA5 and NA6 type)

SPECIFICATIONS

NPUTS:

Pt100

(-200…+850)°C measuring sub-range: 320°C

Pt500

(-200…+850)°C measuring sub-range: 230°C

Pt1000

(-200…+850)°C measuring sub-range: 290°C

J (Fe-CuNi)

(-100…+1100)°C measuring sub-ranges: 350°C, 700°C

K (NiCr-NiAl)

(-100…+1370)°C measuring sub-ranges: 450°C, 950°C

N (NiCrSi-NiSi)

(-100…+1300)°C measuring sub-ranges: 550°C,1000°C

E (NiCr-CuNi)

(-100…+850)°C measuring sub-ranges: 250°C, 520°C

R (PtRh13-Pt)

(0…+1760)°C

S (PtRh10-Pt)

(0…+1760)°C

T (Cu-CuNi)

(-50…+400)°C

Resistance measurement:

0… 10kΩ measuring sub-ranges:
110Ω, 220Ω,450Ω, 950Ω, 2100Ω, 5000Ω

Voltage measurement:

± 300 mV input resistance > 9 MΩ
± 600 V input resistance > 4,2 MΩ
measuring sub-ranges: 19 mV, 35 mV, 75 mV,
155 mV, 5 V, 11 V, 22 V, 45 V, 90 V, 180 V, 360 V

Current measurement:

± 40 mA: input resistance < 4 Ω
± 5 A: input resistance 10 mΩ ±10%
measuring sub-ranges: 5 mA;
11 mA; 23 mA; 1,8 A; 3,8 A

Intensity of the current flowing
through the resistance
thermometer:

< 400 µA

Resistance of wires linking the
resistance thermometer with
the meter:

< 20 Ω/wire

Thermocouple characteristics, acc. EN 60584-1
Resistance thermometer characteristics, acc. IEC 751+A1+A2.


OUTPUTS

Analogue outputs:

– galvanically isolated, with a resolution 0.025% of the range.
– current programmed: 0/4…20 mA, load resistance ≤ 500 Ω
– voltage programmed: 0…10 V, load resistance ≥ 500 Ω
– output response time: 100 ms
– output error: 0.2% of the range
– additional error from ambient temperature change:
± (0.1% of the range/10K)

Relay outputs: 4 relays

– voltageless make contacts – maximal load:
– voltage 250 V a.c., 150 V d.c.
– current 5 A 30 V d.c., 250 V a.c.
– resistance load 1250 VA, 150 W
– programmed alarm thresholds,
– three types of alarms,
– hysteresis defined by means of the lower and upper alarm threshold,
– signalling of alarm operation on the bargraph

8 outputs of OC type (open
collector):

voltageless, of OC type with npn transistor (maximal load 25 mA) range of
added voltages: 5… 30 V d.c.

Digital outputs:

– interface: RS-485,
– transmission protocol: MODBUS,
ASCII 8N1, 7E1, 7O1,
RTU 8N2, 8E1, 8O1, 8N1,
– baud rate: 2400, 4800, 9600 bauds,
– maximal response time to the query frame: 300 ms

Memory parameters:

– meter memory ( recording):
– NA5, NA6: 750 samples (channel 1 or 2)
or 375 samples (channel 1)
+ 375 samples (channel 2)
– minimal recording interval: 1 s

Basic error:

– NA5, NA6
0.1% ± 1 digit

Additional error from ambient
temperature changes:

– NA5, NA6
0.05% of the range/10K

Averaging time:

min 200
ms min 500 ms (temp. ranges)

Rated operation conditions:

– supply voltage depending on the version code:
95…230…253 V a.c./d.c.
20…24…40 V a.c./d.c.
– frequency of the supply voltage: 40…50/60…440 Hz
– ambient temperature: – 10…23…55°C
– storage temperature: – 25… + 85°C
– relative humidity: < 95% (no condensation)
– pre-heating time of the meter: 10 minutes
– working position: any

Sustained overload:

– thermocouples, resistance thermometers: 1%
– voltage, current and resistance measurement: 10%

Short duration overload (3 s):

– inputs of sensors: 30 V
– voltage input > 2.5 V: 10 Un (< 1000 V)
– current input: 10 In

Bargraph resolution:

programmable

Bargraph accuracy:

± 0.5 segment

Servicing:

3 keys:

Protection grade ensured:

– by the housing:
– NA5, NA6: IP 50
– from terminal side: IP 20

Dimensions:

NA5, NA6: 48 x 144 x 100 mm (with terminals)

Cut-out dimensions in the panel:

NA5, NA6: 44+0.5 x 137.5+0.5 mm

Weight:

< 0.4 kg

Power consumption:

< 12 VA

Resistance against voltage decay:

according EN 61000-6-2

Electromagnetic compatibility:

– immunity: EN 61000-6-2
– emission: EN 61000-6-4

Safety requirements according
EN 61010-1:

– installation category: III
– pollution level: 2
– working voltage in relation to the ground: 600 V a.c.

Display Field: NA5: 4 seven-
segment LED displays

digit height: 7 mm
indication range: -1999…9999
multicolour bargraph of 88 mm length
55 segments in 3-colour version
29 segments in 7-colour version

NA6: 2 x 4 seven-segment
LED displays

digit height: 7 mm
indication range: -1999…9999
multicolour bargraph of 88 mm length
48 segments in 3-colour version
27 segments in 7-colour version