Multi-function Meter MPI-530-IT

$2,060.91

MULTI-FUNCTION METER

MODEL: MPI-530-IT

MANUFACTURER: SONEL

MPI-530-IT MULTI-FUNCTION METER FEATURES

  • Innovative memory with possibility of description of measurement points, facilities, names of customers.
  • Power supply from rechargeable of disposable batteries (optional).
  • The meter conforms to EN 61557(requirements for combined instruments).
  • Sonel MPI-530-IT allows testing of residual current devices (RCD), types AC, A, F and B also in IT network.
SKU: AME-71912-7

Description

SONEL Multi-function Meter MPI-530-IT

MPI-530-IT multi-function meter is an instrument for electric shock protection measurements including the option of various methods for measuring earthing and earthing resistance. Additionally the multi-function meter enables its user to analyse power supply parameters, records and displays them on its screen.

Sonel MPI-530-IT allows testing of residual current devices (RCD), types AC, A, F and B also in IT network.

The multi-function meter automatically measures the insulation resistance in a socket and in 3 -, 4 – and 5-wire cables when used with AutoISO-1000C adapter. Measurement results may be continuously verified, depending on user’s demand or according to binding regulations. Memory of the instrument may store tens of thousands of measurements allowing users to store them in a structure of a protocol and describe individual measurement points.

MPI-530-IT multi-function meter is designed for performing check tests of protection against electric shock in AC mains systems. The multi-function meter is used for making measurements and providing results to determine safety of electrical installations.

MPI-530-IT multi-function meter is the equipment to perform complete test and verify on electrical installations according to the most common safety standards (IEC 61557, VDE 0100, BS7671).

 

FEATURES OF MPI-530-IT MULTI-FUNCTION METER

  • Innovative memory with possibility of description of measurement points, facilities, names of customers.
  • Power supply from rechargeable of disposable batteries (optional).
  • The meter conforms to EN 61557(requirements for combined instruments).
  • Sonel MPI-530-IT allows testing of residual current devices (RCD), types AC, A, F and B also in IT network.

Possible measurements of MPI-530-IT Multi-function meter

>Measurement of short circuit loop impedance:

– impedance measurement with resolution 0,001 Ω and 23 A current (44 A phase-to-phase) – short-circuit resistor RZW=10 Ω
– measurement range: 95…440 V, frequency 45…65 Hz,
– measurement of short circuit loop impedance with resolution 0,01 Ω, in protected systems without tripping the RCD’s with I 30 mA Δn
– automatic calculation of short-circuit current, differentiating between phase-to-phase and phase-to-neutral voltage,
– measurements using UNI-Schuko plug with measurement triggering button (also when L and N leads are exchangeable) or 1,2 m, 5 m, 10 m, 20 m test leads, with optional use of 3-phase socket adapters (AGT),
– selection of installation protections and automatic evaluation of measurements
results.

>Tests of residual current devices (RCD), types AC, A and B:
– measurement of general, short-time delay and selective RCD’s with rated residual current of 10, 30, 100, 300, 500 and 1000 mA,
– automatic measurement of all RCD parameters (when the START button is pressed, the meter performs the whole measurement cycle, including the L-PE short circuit loop impedance measurement with 15 mA current),
– user selected waveform of forced leakage current: sinusoidal (start from increasing or decreasing edge), unidirectional pulsating (positive or negative),unidirectional pulsating with DC bias (positive and negative), direct (positive and negative),
– measurement of tripping current I using the ramp current, A
– measurement of tripping time t at ½I , 1I , 2I and 5I
– measurement of touch voltage Ub and protective conductor resistance Re without the RCD tripping,
– detection that L and N conductors are switched in the socket; will not affect the measurement,
– measurement of tripping current I and actual tripping time t at single activation A AI of RCD,
– measurement for 95…270 V voltage.

>Insulation resistance measurements:
– test voltage values: 50 V, 100 V, 250 V, 500 V and 1000 V,
– insulation resistance measurements up to 10 GΩ,
– in-socket measurements using the UNI-Schuko adapter,
– meter is protected against voltage on the tested object and voltage appearing during the measurement,
– auto-discharge of the object after the measurement,
– automatic measurement of all resistance combinations in three-, four- and five core leads using the additional AutoISO-1000C adapter,

– acoustic signalling of five-second periods to enable determining the time profile during the insulation resistance measurements

>Low-voltage resistance measurement of equipotential and protective bonding:

– continuity measurement of protective conductor with 200 mA current in both directions,
– low current measurement with sound signal,
– auto calibration of test leads – leads of any length can be used.

>Earth resistance measurements:

– measurement with 3- and 4-pole methods with 2 additional electrodes,
– measurement with the 3-pole method with and additional clamp,
– measurement with 2-clamp method.

>Soil resistivity measurements

>Illuminance measurements.

>Quick check of PE connection correctness.

>Measurement and recording of voltage, frequency, AC, cosφ and power(active,reactive and apparent), voltage and current harmonics up to 40, THD.

>Checking reactive phase sequence and motor direction of rotation.

 

TECHNICAL SPECIFICATION FOR MPI-530-IT MULTI-FUNCTION METER

>Measurement of short circuit loop impedance ZL-PE, ZL-N, ZL-L
Test current: 23/40 A; measuring range acc. to IEC 61557: 0,13…1999,9 Ω(for 1.2 m test lead):

Display range Resolution Accuracy
0,000…19,999 Ω 0,001 Ω ±(5% m.v. + 0,03 Ω)
20,00…199,99 Ω 0,01 Ω ±(5% m.v. +0,3 Ω)
200,0…1999,9 Ω 0,1 Ω ±(5% m.v. + 3 Ω)
  • Rated voltage: 95…270 V (for ZL-PE and ZL-N) and 95…440 V (for ZL-L)
  • Frequency: 45…65 Hz;

>Measurement of short circuit loop impedance ZL-PE in RCD mode
Test current: 15 mA, measuring range acc. to IEC 61557: 0,50…1999 Ω

Display range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(6% w.m. + 10 digits)
20,0…199,9 Ω 0,1 Ω ±(6% w.m. + 5 digits)
200…1999 Ω 1 Ω ±(6% w.m. + 5 digits)
  • Rated voltage: 95…270 V
  • Frequency: 45…65 Hz

>Measurement of earth resistance RE with the 3p and 4p method
Measuring range acc. to IEC 61557 – 5:

  • 0,50 Ω…1,99 kΩ for test voltage 50 V
  • 0,56 Ω…1,99 kΩ for test voltage 25 V
Display range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(2% m.v. + 4 digits)
10,0…99,9 Ω 0,1 Ω ±(2% m.v.. + 3 digits)
100…999 Ω 1 Ω ±(2% m.v.. + 3 digits)
1,00…1,99 kΩ 0,01 kΩ ±(2% m.v.. + 3 digits)
  • test voltage: 25 V or 50 V rms
  • test current: 20 mA, sinusoidal rms 125 Hz (for fn = 50 Hz) and 150 Hz (for fn = 60 Hz)
  • measurement blocked at interference voltage UN > 24 V
  • maximum measured interference voltage Unmax= 100 V
  • maximum resistance of auxiliary earth electrodes 50 kΩ

>Selective earth resistance measurement with clamp (3p + clamp)

Display range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(8% m.v. + 4 digits)
10,0…99,9 Ω 0,1 Ω ±(8% m.v. + 4 digits)
100…999 Ω 1 Ω ±(8% m.v. + 4 digits)
1,00…1,99 kΩ 0,01 kΩ ±(8% m.v. + 4 digits)
  • measurement with additional current clamp
  • interference current measuring range: up to 9,99 A

>Selective earth measurement with two clamps

Display range Resolution Accuracy
0,00…9,99 Ω 0,01 Ω ±(10% m.v. + 4 digits)
10,0…99,9 Ω 0,1 Ω ±(10% m.v. + 4 digits)
100…999 Ω 0,1 Ω ±(20% m.v. + 4 digits)
  • measurement with transmitting and receiving clamps
  • interference current measuring range: up to 9,99 A

>Soil resistivity mesurement (ρ)

Display range Resolution Accuracy
0,0…99,9 Ωm 0,1 Ωm Depending on accuracy of RE measurement
100…999 Ωm 1 Ωm Depending on accuracy of RE measurement
1,00…9,99 Ωm 0,01 kΩm Depending on accuracy of RE measurement
10,0…99,9 kΩm 0,1 kΩm Depending on accuracy of RE measurement
  • measurement with Wenner’s method
  • distance settable in metres or feet
  • distance range: 1…30 m (1…90 feet)

>Phase sequence indication

  • Phase sequence indication: conforming, non-conforming
  • Mains voltage range UL-L: 100…440 V (45…65 Hz)
  • Display of phase-to-phase voltage values

>Measurements of RCD parameters (voltage range 95…270 V):
RCD tripping test and measurement of tripping time tA (for tA measurement function)

RCD type Current Range Resolution Accuracy
General and short-time delay 0,5*IΔn 0…300 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
General and short-time delay 1*IΔn 0…300 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
General and short-time delay 2*IΔn 0…150 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
General and short-time delay 5*IΔn 0…40 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
Selective 0,5*IΔn 0…500 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
Selective 1*IΔn 0…500 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
Selective 2*IΔn 0…200 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)
Selective 5*IΔn 0…150 ms 1 ms ± (2% m.v. + 2 digits) (for RCD with IΔn = 10 mA and 0,5xIΔn uncertainty: ±(2% m.v. + 3 digits)

accuracy of residual current application: for 0,5*IΔn:-8…0% for 1*IΔn, 2*IΔn, 5*IΔn: 0…8%

>Measurement of RCD tripping current IA for sinusoidal residual current (AC type)

Rated current Meas. range Resolution Test current Accuracy
10 mA 3,3…10,0 mA 0,1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn
30 mA 9,0…30,0 mA 0,1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn
100 mA 33…100 mA 1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn
300 mA 90…300 mA 1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn
500 mA 150…500 mA 1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn
1000 mA 330…1000 mA 1 mA 0,3 x IΔ..1,0 x IΔ ± 5%IΔn

The measurement can be started from positive or negative half-period of forced leakage current

>Measurement of RCD tripping current IA for unidirectional residual current and unidirectional with the 6 mA DC bias (type A)

Rated current Meas. range Resolution Test current Accuracy
10 mA 3,5…20,0 mA 0,1 mA 0,35 x IΔn..2,0 x IΔn ±10%IΔn
30 mA 10,5…42,0 mA 0,1 mA 0,35 x IΔn..1,4 x IΔn ±10%IΔn
100 mA 35,0…140 mA 1 mA 0,35 x IΔn..1,4 x IΔn ±10%IΔn
300 mA 105…420 mA 1 mA 0,35 x IΔn..1,4 x IΔn ±10%IΔn
500 mA 175…700 mA 1 mA 0,35 x IΔn..1,4 x IΔn ±10%IΔn

Measurement for positive or negative half-periods of forced leakage current

>Measurement of RCD tripping current IA for direct residual current (type B)

Rated current Meas. range Resolution Test current Accuracy
10 mA 2,0…20,0 mA 0,1 mA 0,4 x IΔn..2,0 x IΔn ±10%IΔn
30 mA 6…60 mA 1 mA 0,4 x IΔn..2,0 x IΔn ±10%IΔn
100 mA 20…200 mA 1 mA 0,4 x IΔn..2,0 x IΔn ±10%IΔn
300 mA 60…600 mA 1 mA 0,4 x IΔn..2,0 x IΔn ±10%IΔn
500 mA 100…1000 mA 1 mA 0,4 x IΔn..2,0 x IΔn ±10%IΔn
  • Measurement for positive or negative half-periods of forced leakage current
  • IΔn – rated residual current

>Insulation resistance measurements
Measuring range acc. to IEC 61557 – 2:

  • for UN = 50 V: 50 kΩ…250 MΩ
  • for U= 100 V: 100 kΩ…500 MΩ
  • for UN = 250 V: 250 kΩ…999 MΩ
  • for UN = 500 V: 500 kΩ…2 GΩ
  • for UN = 1000 V: 1,000 MΩ…9,99 GΩ
Display range*) Resolution Accuracy
0…1999 kΩ 1 kΩ ±(3% m.v. + 8 digits)
2,00…19,99 MΩ 0,01 MΩ ±(3% m.v. + 8 digits)
20,0…199,9 MΩ 0,1 MΩ ±(3% m.v. + 8 digits)
200…999 MΩ 1 MΩ ±(3% m.v. + 8 digits)
1,00…9,99 MΩ 0,01 GΩ ±(4% m.v. + 6 digits)

*) not greater than measuring range for given voltage

>Low-voltage measurement of resistance and circuit continuity
Measurement of protective conductor continuity with the ±200 mA current

Range Resolution Accuracy
0,00…19,99 Ω 0,01 Ω ±(2% m.v. + 3 digits)
20,0…199,9 Ω 0,1 Ω ±(2% m.v. + 3 digits)
200…400 Ω 1 Ω ±(2% m.v. + 3 digits)
  • voltage on open terminals: 4…9 V
  • output current at R < 2 Ω: min. 200 mA
  • autocalibration of test leads
  • measurements for both current polarities

>Illuminance measurement

Range Resolution Accuracy
0,1…99,9 lx 0,1 lx ±(5% m.v. + 2 digits)
100…999 lx 1 lx ±(5% m.v. + 2 digits)
1,00…9,99 klx 0,01 lx ±(5% m.v. + 2 digits)
10,0…19,9 klx 0,1 lx ±(5% m.v. + 2 digits)

– measurement in luxes (lx) or feet-candles (fc)

>ANALYSIS AND RECORDING OF SINGLE-PHASE SYSTEM

  • Voltage measurement ULN: 0…500 V
  • Frequency range of measured voltages: 45,0…65,0 Hz
  • Frequency measurement range for 50…500 V voltages: 45,0…65,0 Hz (basic uncertainty max. ± 0,1% m.v. + 1 digit)
  • cosφ measurement: 0,00…1,00 (resolution 0,01)
  • Measurement and recording in single-phase system

>Current measurement (True RMS)

Clamps Range Resolution Accuracy*
C-3, C-6 0,0…99,9 mA 0,1 mA ±(5% m.v. + 3 digits)
C-3, C-6 100…999 mA 1 mA ±(5% m.v. + 3 digits)
C-3,C-6 F-1, F-2, F-3 1,00…9,99 A 0,01 A ±(5% m.v. + 5 digits) (C-3, C-6) ±(0,1% In + 2 digits) (F-1, F-2, F-3)
C-3,C-6 F-1, F-2, F-3 10,0…99,9 A 0,1 A ±(5% m.v. + 5 digits) (C-3, C-6) ±(0,1% In + 2 digits) (F-1, F-2, F-3)
C-3,C-6 F-1, F-2, F-3 100…999 A 1 A ±(5% m.v. + 5 digits) (C-3, C-6) ±(0,1% In + 2 digits) (F-1, F-2, F-3)
F-1, F-2, F-3 1,00…3,00 kA 0,01 kA ±(5% m.v. + 5 digits) (C-3, C-6) ±(0,1% In + 2 digits) (F-1, F-2, F-3)

* the accuracy of current clamps must also be taken into account

>Measurement of active power P, reactive power Q, apparent power S and cosφ

Range [W], [VA], [var] Resolution [W], [VA], [var] Accuracy*
0…999 1 ±(7% m.v. + 3 digits)
1,00…9,99 k 0,01 k ±(7% m.v. + 3 digits)
10,0…99,9 k 0,1 k ±(7% m.v. + 5 digits)
100…999 k 1 k ±(7% m.v. + 5 digits)
1,00…1,50 M 0,01 M ±(7% m.v. + 5 digits)
  • voltage range: 0…500 V
  • current range: 0…1000 A (3000 A)
  • mains rated frequency fn: 50 Hz, 60 Hz

>Voltage harmonics measurement

Range Resolution Nr harm. Accuracy
0,0…500 V 0,1 (1*) V 1,2,…15 ±(5% m.v. + 3 digits)
0,0…500 V 0,1 (1*) V 16,…40 ±(5% m.v. + 10 digits)
  • in addition display of h02…h40 values as percent of h01 (up to 999%) from 300 V to 500 V

>THD (in relation to the 1 st harmonics)

Resolution Accuracy
THD-F voltage (h = 2…40) 0,0…999,9% for URMS ≥ 1% Unom 0,1% ±5%
THD-F current (h = 2…40) 0,0…999,9% for IRMS ≥ 1% Inom 0,1% ±5%

 

NOTE: “m.v.” means “ measured value”

The instruments conforms to:

  • EN 61010 – 1 (general safety requirements)
  • EN 61010 – 031 (detailed safety requirements)
  • EN 61326 (electromagnetic compatibility)
  • EN 61557 – 10 (requirements for combined instruments)
  • IEC 60364 – 6-61 / HD 60364 – 6 (measurements – verification)
  • IEC 60364 – 4-41 / HD 60364 – 4-41 (measurements – protection against electric shock)
  • EN 04700 (measurements – acceptance tests)
  • EN 12464 (lighting of work places)
  • DIN VDE 0100
  • DIN VDE 0413
  • BS 7671

>Electric security for MPI-530-IT multi-function meter:

– type of insulation: double, according to EN 61010-1and IEC 61557, EMC
– measurement category: IV 300 V acc. to EN 61010-1
– protection class acc. to EN 60529: IP54

>Other technical data for MPI-530-IT multi-function meter:

– power supply: Ni-MH rechargeable or LR14 alkaline disposable batteries (4 pcs.) (optional)